Display and control panel AMS 338i
50
AMS 338
i
Leuze electronic
Viewing and editing parameters
As long as parameter enabling is activated, the entire AMS 338
i
display is inverted.
As long as parameter enabling is activated, communication between control and AMS 338
i
is interrupted. The continued networking via BUS OUT is retained.
Notice!
If a password was stored, parameter enabling is not possible until this password is entered,
see "Password for parameter enabling" below.
Password for parameter enabling
Parameter entry on the AMS 338
i
can be protected with a password. The password can be
changed via the CoE online dictionary, object 0x2300
h
, sub-index 0x05
h
.
For parameter enable via the display, the password must be entered. If parameter enabling
has been activated after successfully entering the password, parameters can temporarily
be changed via the display.
After parameter enable has been deactivated, all changes made at the display are over-
written by the CoE online dictionary, object 0x2300
h
, sub-index 0x05
h
(see above). If a new
password has been assigned, this, too, is overwritten by the password defined in the online
dictionary.
Notice!
The
master password 2301
can enable the AMS 338
i
at any time.
Press the enter button to switch on parameter
enabling.
Parameter enabling
o
OFF
ON
The PWR LED illuminates orange; the display is
inverted. You can now set the individual parameters
on the display.
Press the ESC button twice to return to the Param-
eter menu.
ESC
ESC