![Leuze electronic AMS 338i Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/leuze-electronic/ams-338i/ams-338i_technical-description_1883970065.webp)
EtherCAT interface
62
AMS 338
i
Leuze electronic
9.7.6.4
Object 2010
h
Position limit value range 1
The position limit value range 1 object defines a distance range with lower and upper limits.
If the measured value lies outside the configured range, the corresponding status bits are
set in objects 2050
h
, 2051
h
and 2060
h
.
Sub-index 02 / Sub-index 03
The lower and upper position limit values are entered in mm or inch/100 according to the
unit selected.
9.7.6.5
Object 2011
h
Position limit value range 2
The position limit value range 2 object defines a distance range with lower and upper limits.
If the measured value lies outside the configured range, the corresponding status bits are
set in objects 2050
h
, 2051
h
and 2060
h
.
Sub-index 02 / Sub-index 03
The lower and upper position limit values are entered in mm or inch/100 according to the
unit selected.
Index
Sub-
index
Name
Data type
Access
Value range
Remark
(hex)
(hex)
Minimum
Maximum
Default
2010
01
Enable posi-
tion limit
value 1
u8
rw
0
1
0
0 = deactivated
1 = activated
02
Lower posi-
tion limit
value 1
int 32
rw
-999999
999999
0
see remarks below
03
Upper posi-
tion limit
value 1
int 32
rw
-999999
999999
0
see remarks below
Index
Sub-
index
Name
Data type
Access
Value range
Remark
(hex)
(hex)
Minimum
Maximum
Default
2011
01
Enable posi-
tion limit
value 2
u8
rw
0
1
0
0 = deactivated
1 = activated
02
Lower posi-
tion limit
value 2
int 32
rw
-999999
999999
0
see remarks below
03
Upper posi-
tion limit
value 2
int 32
rw
-999999
999999
0
see remarks below