7.3  Faults

7.3.1  FAULT CODES

Below are fault codes mostly caused by hardware operations. Additional fault codes 
are listed in Programmer’s manual.

Fault 
Code Fault

Description

F_OU

Over voltage

Drive bus voltage reached the maximum level, typically due 
to motor regeneration

F_FB

Feedback error

Resolver signal lost or at least one motor hall sensor is 
inoperable or not connected.

F_OC

Over current

Drive exceeded peak current limit. Software un-capable to 
regulate current within 15% for more then 20mS. Usually 
results in wrong motor data or poor tuning. 

F_Ot

Over temperature

Drive heatsink temperature has been reached maximum 
rating.

F_EF

External fault input 
activated

Digital input was programmed as external fault input and has 
been activated.

F_OS

Over speed

Motor reached velocity above its specified limit

F_PE

Excess position error

Position error exceeded maximum value.

F_bd

Bad motor data

Motor profile data invalid or no motor is selected 

F_09

Motor over 
temperature

Optional motor temperature sensor (PTC) indicates that the 
motor windings have reached maximum temperature

F_10

Subprocessor 
failure

Error in data exchange between processors. Usually 
happens when EMI level is high resulting from poor shielding 
and grounding. 

F_14

Undervoltage

Happens bus voltage level drops below 50% of nominal bus 
voltage while drive is operating. Attempt to enable drive with 
low bus voltage also result in this fault.

F_15

Hardware overload 
protection

Happens if phase current at any time becomes higher than  
400% of total drive’s current capability for more then 5uS.

F_33

Negative Limit Switch

Negative limit switch is activated

F_34

Positive Limit Switch

Positive limit switch is activated

F_36

Drive Disabled by 
User at Enable Input

Drive disabled while operating or attempt to enable drive 
without deactivating “Inhibit input”. “Inhibit” input has reverse 
polarity.

There are additional error codes related to the programming of the 940. Please 
reference the programmer’s manual for more information.

7.3.2  Fault Event

When drive encounters any fault, the following events occur:

•  Drive is disabled

•  Internal status is set to “Fault”

•  Fault number is logged in the drive’s internal memory for later interrogation 

•  Digital output(s), if configured for “Run Time Fault”, are asserted

•  Digital output(s), if configured for READY, are de asserted

•  If the display is in the default status mode, the LEDs display F_XX where XX is 

current fault code.

•  “Enable” LED turns OFF

7.3.3  Fault Reset

Fault reset is accomplished by disabling or re-enabling the drive depending on the 
setting of the “Reset option” parameter (section 6.3.10).

Содержание PositionServo 940

Страница 1: ...Model 940 USERS MANUAL S94P01B S929...

Страница 2: ...y kind with respect to this material including but not limited to the implied warranties of its merchantability and tness for a given purpose AC Tech assumes no responsibility for any errors that may...

Страница 3: ...e 16 5 1 4 P4 Motor Feedback second loop encoder input 17 5 1 5 P5 24 VDC Back up Power Input 19 5 1 6 P6 Braking Resistor and DC Bus 19 5 1 7 Connectors and Wiring Notes 19 5 1 8 P11 Resolver interfa...

Страница 4: ...Enable switch function 40 6 3 21 User Units 40 6 4 Communication 40 6 4 1 IP Setup 40 6 4 2 RS 485 con guration 40 6 4 3 Modbus baud rate 40 6 4 4 Modbus reply delay 40 6 5 Analog I O Group 40 6 5 1...

Страница 5: ...n guration of the PositionServo 48 8 3 Position mode operation gearing 50 8 4 Dual loop feedback 50 8 5 Enabling the PositionServo 51 8 6 Tuning in velocity mode 51 8 7 Tuning in position mode 53 9 Sa...

Страница 6: ...of impending danger Consequences if disregarded Death or severe injuries Warning of a general danger WARNING Warns of potential very hazardous situations Consequences if disregarded Death or severe in...

Страница 7: ...s including analog voltage RS485 interface PPP and Modbus RTU Ethernet interface CANopen interface digital pulse train and master encoder reference The control will operate in current torque velocity...

Страница 8: ...only for industrial purposes Drive systems with E94P servo inverters comply with the EMC Directive if they are installed according to the guidelines of CE typical drive systems can be used for operat...

Страница 9: ...s voltage for operation on 50 60 Hz AC supplies 48 Hz 0 62Hz 0 2 Connection of 120VAC 45 V 132 V to input power terminals L1 and N on these models doubles the voltage on motor output terminals U V W f...

Страница 10: ...th Up to 200 Hz Accuracy 1 encoder count 2 4 Connections and I O RS232 serial interface Standard 9 pin D shell DCE P2 Encoder Feedback primary Standard 15 pin D shell P4 Encoder Feedback secondary Opt...

Страница 11: ...P020S2F 67 190 235 1 3 E94P040S2F 69 190 235 1 5 E94P080S2F 88 190 235 1 9 E94P100S2F 103 190 235 2 2 E94P020Y2N 67 190 190 1 3 E94P040Y2N 69 190 190 1 5 E94P080Y2N 95 190 190 1 9 E94P100Y2N 115 190 1...

Страница 12: ...S94P01B 10 3 2 Clearance for Cooling Air Circulation S924...

Страница 13: ...ient room for access to the terminal block Mount the drive away from any and all heat sources Operate within the speci ed ambient operating temperature range Additional cooling with an external fan ma...

Страница 14: ...g 4 2 1 General guidelines Lenze recommends the use of single point grounding SPG for panel mounted controls Serial grounding a daisy chain is not recommended The SPG for all enclosures must be tied t...

Страница 15: ...only for servo control manufacturers such as Lenze but the user as well Proper shielding grounding and installation practices are critical to EMI reduction 4 2 3 Enclosure The panel in which the Posit...

Страница 16: ...itionServo drives Connect the external line fuse in series with the AC line voltage input Use fast acting fuses rated for 250 VAC or 600 VAC depending on model and approximately 200 of the maximum RMS...

Страница 17: ...elds should be terminated in a like manner Lenze recommends Lenze cables for both the motor power and feedback These are available with appropriate connectors and in various lengths Contact your Lenze...

Страница 18: ...rface P3 is a 50 pin SCSI connector for interfacing to the front end of the controllers It is strongly recommended that you use OEM cables to aid in satisfying CE requirements Contact your Lenze repre...

Страница 19: ...output 4 Emitter 1 See Note 1 Section 5 1 7 Connector and Wiring Notes 2 See Note 2 Section 5 1 7 Connector and Wiring Notes 3 See Note 3 Section 5 1 7 Connector and Wiring Notes 5 1 4 P4 Motor Feedba...

Страница 20: ...the encoder An encoder resolution of 2000 PPR pre quadrature or higher is recommended Using P4 as second encoder input for dual loop operation P4 can be used as a second loop encoder input in situatio...

Страница 21: ...SSIGNMENTS BRAKE RESISTOR AND DC BUS Pin Terminal Function 1 B Positive DC Bus Brake Resistor 2 B 3 BR Brake Resistor 4 B Negative DC Bus 5 B 5 1 7 Connectors and Wiring Notes Note 1 Encoder Inputs Ea...

Страница 22: ...ARSV3 standard When the motor pro le is loaded from the motor database or from a custom motor le the drive will select the primary feedback source based on the motor data entry When using a Lenze moto...

Страница 23: ...r Option Module includes a 9 pin D shell male connector When using a Lenze motor with encoder feedback and a Lenze encoder cable the pins are already con gured for operation If a non Lenze motor is us...

Страница 24: ...iming characteristics for Step And Direction signals S905 Timing characteristics for Master Encoder signals Input type output compatibility Insulated compatible with Single ended or differential outpu...

Страница 25: ...as Special Purpose each output OUT1 OUT4 can be assigned to one of the following functions Not assigned Zero speed In speed window Current limit Run time fault Ready Brake motor brake release Please n...

Страница 26: ...groups of 4 Inputs A1 A4 Inputs B1 B4 and Inputs C1 C4 Each group A B and C have their own corresponding shared COM terminal ACOM BCOM and CCOM All inputs have separate software adjustable de bounce t...

Страница 27: ...Vref AIN1 AIN1 and 10V Vref 10V Reference Source Reference Source Single ended Differential S909 AIN2 AIN2 P3 20 and P3 21 The analog reference input can accept up to a 10V analog signal across AIN2...

Страница 28: ...he front panel display Please note that baud rate and address are applied to both RS232 and RS485 interfaces in this case If used for Modbus RTU communications the Modbus baud rate is set as a paramet...

Страница 29: ...ll need to be provided to create a custom motor pro le The auto phasing feature of the 940 allows the user to correctly determine the relationship between phase voltage and hall sensor signals elimina...

Страница 30: ...Note If the drive is ENABLED a new motor cannot be set You can only set a new motor when the drive is DISABLED To View selected motor parameters or to make a new motor selection Click Click here to ch...

Страница 31: ...e B leads A for CW Halls order and inverted elds as they are You can execute autophasing see section 5 6 2 to set them correctly 2 Enter motor model and vendor in the top edit boxes Motor ID cannot be...

Страница 32: ...ety reminder dialog appears Verify that it is safe to run the motor then click Proceed and wait until autophasing is completed Note If there was a problem with the motor connection hall sensor connect...

Страница 33: ...Amps RMS Do not use the peak current rating Note Sometimes the phase current rating will not be given The equation below may be used to obtain the nominal continuous phase to phase winding current fro...

Страница 34: ...ted result to 3 signi cant places Maximum Motor Speed in RPM This is also listed as Speed Vt motor speed at the terminal voltage rating The maximum motor speed will typically be a round even value bet...

Страница 35: ...can determine which Hall Voltage is in phase with the Vrs Output Voltage by drawing vertical lines at those points where it crosses the horizontal line zero The dashed lines at the zero crossings abo...

Страница 36: ...e it s assumed by the software that the motor shaft rotates CW when looking at the mounting face of the motor For that rotation Encoder phase A must lead phase B If it does leave check box unchecked O...

Страница 37: ...comes from an external device AIN1 or MA MB or from the drives internal variables digital reference and trajectory generator will depend on the parameter settings Refer to Parameters group in MotionVi...

Страница 38: ...ty mode the servo controller regulates motor shaft speed velocity proportional to the analog input voltage at input AIN1 if parameter Reference is set to External Otherwise the reference is taken from...

Страница 39: ...t is allowed for up to 2 seconds After this two second limit the current limit will be reduced to the value set in the Current Limit parameter When the motor current drops below nominal current for tw...

Страница 40: ...aster Encoder Electronic Gearing Refer to section 5 2 1 for details on these inputs 6 3 10 Fault Reset Option The FAULT RESET OPTION selects the type of action required to reset the drive after a FAUL...

Страница 41: ...r ratio This parameter is used to set the scale between the reference pulse train when operating in position mode and the system feedback device In a single loop con guration the system feedback devic...

Страница 42: ...tion button opens dialog for TCP IP related parameters setup 6 4 2 RS 485 con guration This parameter sets how the optional RS485 interface will function The RS485 interface can be con gured for norma...

Страница 43: ...AIN1 P3 24 and 25 to zero volts and then click this button Any offset voltage at the analog input will be adjusted out and the adjustment value will be stored in the Analog input offset parameter 6 6...

Страница 44: ...hen the condition AT SPEED is set to TRUE in the internal controller logic The AT SPEED condition can also trigger a programmable digital output if selected For example if AT SPEED is set for 1000 RPM...

Страница 45: ...ference between the commanded position of the motor shaft and the actual shaft position By adjusting the proportional gain the bandwidth of the drive is more closely matched to the bandwidth of the co...

Страница 46: ...tool Phase Current RMS Motor phase current Phase Current Peak Motor peak current Iq Current Measures the motor Iq torque producing current Motor Velocity Actual motor speed in RPM Commanded Velocity D...

Страница 47: ...nning diS drive disabled F_XX drive fault Where XX is the fault code section 7 3 2 Hx xx Hardware revision e g H2 00 Fx xx Firmware revision e g F2 06 bAUd RS232 RS485 normal mode baud rate to set sel...

Страница 48: ...tus and activity as well as troubleshoot any faults S913 LED Function Description A Enable Orange LED indicates that the drive is ENABLED running B Regen Yellow LED indicates the drive is in regenerat...

Страница 49: ...esulting from poor shielding and grounding F_14 Undervoltage Happens bus voltage level drops below 50 of nominal bus voltage while drive is operating Attempt to enable drive with low bus voltage also...

Страница 50: ...P1 Mains power must be as de ned on the drive s data label see section 2 1 If the motor is equipped with an encoder connect the encoder cable to the PositionServo feedback connector P4 If the motor i...

Страница 51: ...lt 11 Click OK twice to dismiss both dialog boxes 12 From Node menu choose Connect Drive 13 Click Connect one button type 1 in the address box and press OK to dismiss dialog 14 Drive connects and its...

Страница 52: ...er encoder 1000 pulses revolution post quadrature Desired gear ratio is 3 1 Solution Ratio is motor encoder PPR divided by master encoder PPR times the gear ratio Motor PPR Master PPR 3 1 4000 1000 3...

Страница 53: ...hile the drive is enabled the drive will be disabled and will generate a fault 36 WARNING Enabling the servo drive allows the motor to operate depending on the reference command The operator must ensu...

Страница 54: ...e button on the toolbar 11 If the motor vibrates uncontrollably disable the drive rest P Gain to 1000 and re enable the drive 12 Slowly increase the Velocity P gain and observe the motor velocity wave...

Страница 55: ...ls 8 7 Tuning in position mode In this mode the Velocity gains should be set rst 1 Perform velocity loop tuning as per section 8 6 Select I Gain value for minimum overshoot 2 Make sure that the drive...

Страница 56: ...the drive 14 Set oscilloscope channel 1 to Iq current Set the scale to the appropriate value to see a full current pulse 15 Observe that current Iq waveform Check to make sure that there isn t any si...

Страница 57: ...S94P01B 55 9 Sample Motor Responses to Gain Settings 9 1 Motor response to gain settings Velocity mode Initial settings S934...

Страница 58: ...in the Gain Scaling window The current value is very close to the maximum but since the P gain is maxed out we can t determine if we have achieved optimum settings Also notice that the oscilloscope Ti...

Страница 59: ...Reference the next section Velocity P gain 20322 Velocity I gain 20 Gain Scaling 1 We start to see a small overshoot at the leading edge of the Motor Velocity wave but the current doesn t increase any...

Страница 60: ...equires stiffness at zero or near zero velocity and long term stability is desired you can increase I Gain so that the overshoot reaches 30 see next section S938 Large I Gain I Gain 7935 Overshoot 20...

Страница 61: ...e Motor Velocity waveform The current waveform also has a small trace of instabilities at the at portion of the waveform S940 Velocity P gain is too high Velocity P gain 22720 Velocity I gain 20 Gain...

Страница 62: ...e D gain as well to overcome this problem S942 P gain increase Position P gain 8700 Position D gain 0 Position I gain 0 Position I limit 0 Positive effect Position error decreased Problem Noticeable o...

Страница 63: ...inated by D gain Side effects Possible high noise produced by high P and D gains at 0 velocity This problem arises since encoder has nite resolution A compromise might have to be made by setting the P...

Страница 64: ...aveform Treatment Decrease the P gain setting until oscillation disappears S945 P and D gains setting check corrected Position P gain 12673 Position D gain 16000 Position I gain 0 Position I limit 0 P...

Страница 65: ...g Suggested Solution Check that line fuses are properly sized for the motor being used Check motor cable and incoming power for shorts Check that you follow recommendation for shielding and grounding...

Страница 66: ...S94P01B 64 Notes...

Страница 67: ......

Страница 68: ...AC Technology Corporation member of the Lenze Group 630 Douglas Street Uxbridge MA 01569 Telephone 508 278 9100 Facsimile 508 278 7873 Document S94P01B...

Отзывы: