Connection according to UL
The following data is valid for a three-phase mains connection with 480 V.
Mains connection with QUICKON connector
Motor
MSEMA
☐☐
063-42
MSEMA
☐☐
080-32
Connection
X3
Connection type
QUICKON connector
cable cross‐section
Typ.
AWG
14
14
Min.
AWG
16
16
Max.
AWG
14
14
General UL notes
WARNING!
▶
UL marking
▶
Use 75 °C copper wire only, except for control circuits.
▶
Maximum conductor size is AWG14.
▶
Cord connected drives are for use only in NFPA 79 applications.
▶
Overload protection: 125 % of rated FLA
▶
Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit pro-
tection must be provided in accordance with the National Electrical Code and any additional local codes.
▶
CAUTION - Risk of electric shock. Do not disconnect under load.
▶
Marquage UL
▶
Utiliser exclusivement des conducteurs en cuivre 75 °C, sauf pour la partie commande.
▶
Taille de conducteur maximale : AWG14.
▶
Les entraînements avec câble d’alimentation sont destinés exclusivement à des applications conformes à
la norme NFPA 79.
▶
Protection contre les surcharges : homologuée pour 125 % du courant assigné à pleine charge.
▶
La protection statique intégrée n’offre pas la même protection qu’un disjoncteur. Une protection par dis-
joncteur externe doit être fournie, conformément au National Electrical Code et aux règlementations
locales applicables.
▶
ATTENTION ! Risque de choc électrique. Ne pas débrancher l’équipement sous charge.