8
Process data transfer
8.4
CiA402 PDO mapping in case of Inverter Drive 8400 TopLine P
66
Lenze · E84AYCET communication module (EtherCAT) · Communication Manual · DMS 5.0 EN · 05/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.4
CiA402 PDO mapping in case of Inverter Drive 8400 TopLine P
The Inverter Drive 8400 TopLine P supports the CiA402 profile.
The following tables show an overview of the CiA402 objects used in the receipt PDO (Rx-PDO) and
transmit PDO (Tx-PDO).
Receipt PDO (Rx-PDO)
Software manual/online help for the Inverter Drive 8400 TopLine P
Here you will find detailed information on the functions of the CiA402 objects.
Word
Index
[hex]
Description
1
0x6040
Control word
2
0x6060
Operating mode
0x60FE.1
Physical outputs
3
0x6042
Target velocity for "Velocity Mode" (is not supported yet)
4
0x607A
Target position
5
6
0x60B1
Offset for velocity
7
8
0x60B2
Offset for torque
9
0x60B8
Touch probe function
10
0x60E0
Positive torque limit
11
0x60E1
Negative torque limit
12
0xXXXX
Upper speed limit for "CST Mode" (is not supported yet)
13
14
0xXXXX
Lower speed limit for "CST Mode" (is not supported yet)
15
16
0xA580.1
Freely interconnectable