5
Installation
5.1
Mechanical installation
22
Lenze · E84AYCET communication module (EtherCAT) · Communication Manual · DMS 5.0 EN · 05/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.1
Mechanical installation
The communication module can be plugged into the MCI slot or removed while the frequency
inverter is switched on. When the module is plugged in, it is recognised automatically and checked
for plausibility regarding its function and version.
5.1.1
Mounting for standard devices 0.25 kW and 0.37 kW
[5-1]
Mounting for standard devices 0.25 kW and 0.37 kW
Mounting steps
1. Use a screwdriver to lever out the cover of the MCI slot of the standard device and remove
it (1, 2).
2. Loosen the securing screw for the communication module at the standard device (3).
3. Insert the communication module into the MCI slot of the standard device (4).
4. Tighten the securing screw again (5).