Parameter | Name:
C13221 | Display: Last data from master
Data type: UNSIGNED_16
Index: 11354 = 0x2C5A
Display of the last data transmitted from the master to the communication unit.
Value is bit-coded:
Bit 0 D0
Bit 1 D1
Bit 2 D2
Bit 3 D3
Bit 4 PR0
Bit 5 PR1
Bit 6 PR2
Bit 7 PR3
Bit 8 Reserved
... ...
Bit 15 Reserved
Subcodes
Info
C13221/1
Last data from master to slave 1
C13221/2
Last data from master to slave 2
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13852 | All words to standard device
Data type: UNSIGNED_16
Index: 10723 = 0x29E3
Display of process data words 1 ... 8 which are transmitted from the communication unit to the drive unit.
Subcodes 1 ... 8 display all the process data words from the communication unit.
Display range
(min. value | unit | max. value)
0
65535
Subcodes
Info
C13852/1
Word 1 of process data from module to standard device
...
...
C13852/8
Word 8 of process data from module to standard device
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13853 | All words from standard device
Data type: UNSIGNED_16
Index: 10722 = 0x29E2
Display of process data words 1 ... 8 which are transmitted from the drive unit to the communication unit.
Subcodes 1 ... 8 display all the process data words from the drive unit.
Display range
(min. value | unit | max. value)
0
65535
Subcodes
Info
C13853/1
Word 1 process data from standard device to module
...
...
C13853/8
Word 8 of process data from standard device to module
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM