Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 5.0 - 02/2019
45
Parameter data transfer
CTT2: Read parameter value
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.1
CTT2: Read parameter value
• Acyclic read request from the master to the slave:
• Response from slave to master is OK:
• Response from slave to master has failed:
Byte
Contents / value
0
CTT2: Code
• Index
0x12
(18): Acyclic read request
1
CTT2: Index
• Index
0x10
(16): Read parameter value
2
CTT2: Number of bytes
• Value depends on the master.
Byte
Contents / value
0
CTT2: Code
• Index
0x52
(82): Acyclic read request is OK.
1
Data type / number of bytes
Bit 7 = 0
Octet string (text)
• Bits 0 ... 6 = Number of string characters
Bit 7 = 1
Number (4 data bytes):
• Bits 0 ... 2 = Number of valid bytes
(1 = 1 byte, 2 = 2 bytes, 3 = 3 bytes, 4 = 4 bytes)
2
1st character of the character string or data byte 1 (MSB)
3
2nd character of the string or data byte 2
4
3rd character of the string or data byte 3
5
4th character of the string or data byte 4 (LSB)
6
5th character of the string
...
...
n
n-th character of the string
Byte
Contents / value
0
CTT2: Code
• Index
0x92
(146): Acyclic read request is not OK.
1
CTT2: Standard error code
2
Error code (MSB)
3
Error code
4
Error code
5
Error code (LSB)