Parameter data transfer
CTT2: Acyclic device error codes
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.7
CTT2: Acyclic device error codes
Error code [hex]
Description
Byte 0
(MSB)
Byte 1
Byte 2
Byte 3
(LSB)
0x00
0x00
0x00
0x00
Transfer aborted
0x06
0x03
0x00
0x00
• No access rights
• Invalid access
• Read-only object
0x06
0x05
0x00
0x10
Invalid service
0x06
0x05
0x00
0x11
Invalid subindex
0x06
0x05
0x00
0x12
Data length too large
0x06
0x05
0x00
0x13
Data length too small
0x06
0x06
0x00
0x00
Object is no parameter
0x06
0x07
0x00
0x00
Object does not exist
0x06
0x08
0x00
0x00
Data (types) do not correspond
0x08
0x00
0x00
0x00
• Invalid function
• Request cannot be executed
• No operation
0x08
0x00
0x00
0x20
Request cannot be executed at the moment
0x08
0x00
0x00
0x21
No operation due to local control
0x08
0x00
0x00
0x22
Request cannot be executed due to the device state
0x08
0x00
0x00
0x30
• Value beyond the range
• Parameter can only be changed when the controller is inhibited
(CINH)
0x08
0x00
0x00
0x31
Parameter value too high
0x08
0x00
0x00
0x32
Parameter value too low
0x08
0x00
0x00
0x33
Value range of the (sub)parameter exceeded
0x08
0x00
0x00
0x34
Value range of the (sub)parameter too high
0x08
0x00
0x00
0x35
Value range of the (sub)parameter too low
0x08
0x00
0x00
0x36
Maximum value lower than minimum value
0x08
0x00
0x00
0x41
Communication object cannot be displayed
0x08
0x00
0x00
0x42
Process data length exceeded
0x08
0x00
0x00
0x43
General value collision
0x08
0x00
0x00
0x50
• Block access has failed
• One or several parameter accesses within the block have failed
• Read exception list for more details
0x08
0x00
0x00
0x80
Hardware error