Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 5.0 - 02/2019
19
Technical data
Communication time
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.3
Communication time
The communication time is the time between the start of a request and the arrival of the
corresponding response.
The communication times in an AS-i network depend on the ...
• processing time in the inverter;
• frame runtime (baud rate / frame length);
• nesting depth of the network.
Processing time in the inverter
There are no interdependencies between parameter data and process data.
Data
Processing time
Process data
Approx. 2 ms
+ 0 ... 1 ms
+ 1 ... x ms
Update cycle
Processing time in the module
Runtime of the application task of the technology
application used (tolerance)
Parameter data
Approx. 30 ms + a tolerance of 20 ms (typically)
For some codes, the processing time may be longer (see software manual/
»Engineer« online help "Inverter Drives 8400 motec").