5
Installation
5.2
Electrical installation
28
Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 10.2 EN · 11/2018 · TD06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Colour code of the Ethernet cable
[5-8]
Ethernet plug in accordance with EIA/TIA 568A/568B
Note!
Wiring and colour code are standardised in EIA/TIA 568A/568B.
In accordance with the industrial standard, the use of 4-pin Ethernet cables is
permissible. The cable type only connects the assigned pins 1, 2, 3 and 6 to one another.
E94YCEI004A
Pair
Pin
Signal
EIA/TIA 568A
EIA/TIA 568B
3
1
Tx +
White / Green
White / Orange
2
Tx -
Green
orange
2
3
Rx +
White / Orange
White / Green
1
4
blue
blue
5
White / Blue
Blue / White
2
6
Rx -
orange
Green
4
7
White / Brown
White / Brown
8
brown
brown