Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 10.2 EN · 11/2018 · TD06
135
14
Parameter reference
14.3
Parameters of the communication module for slot MXI2
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C14899
C14900
C14901
C14902
Parameter | Name:
C14899 | Station alias
Data type: UNSIGNED_16
Index: 9676 = 0x25CC
This code serves to set a station alias.
In order to use a station alias, you must select a value > "0".
• The station alias must only be set if the device is part of a "hot connect" group or integrated in the modular
machine configuration of Lenze.
• The station alias must be unambiguous and must only be assigned once within the EtherCAT network.
• Use the same station alias in the EtherCAT master and in the slave.
Setting range
(min. value | unit | max. value)
Lenze setting
0
32767
0
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C14900 | Firmware: Product type
Data type: VISIBLE_STRING
Index: 9675 = 0x25CB
The code contains a string with a length of 8 bytes.
The following identification code is output: "E94AFCET".
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C14901 | Firmware compilation date
Data type: VISIBLE_STRING
Index: 9674 = 0x25CA
The code contains a string with a length of 20 bytes. The creation date ("MM DD YYYY") and the time ("hh:mm:ss")
of the software are output here.
Example: "Mar 21 2005 12:31:21"
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C14902 | Firmware version
Data type: VISIBLE_STRING
Index: 9673 = 0x25C9
The code contains a string with a length of 11 bytes. The firmware version is output here.
Example: "02.00.00.36"
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT