10. Align the top edge of the EMI-protective panel with the top side of the hard-disk-drive cage and then
pivot the EMI-protective panel down until it snaps into position.
Figure 73. Installing the EMI-protective panel
11. Disconnect the SATA cable for the removed non-hot-swap hard disk drive from the system board and
save the cable for future use.
12. Close and lock the front door.
13. If you are instructed to return the old non-hot-swap hard disk drive, follow all packaging instructions and
use any packaging materials that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the removal procedure, go to “Completing the parts replacement” on page 177. Then, you
might need to reconfigure RAID for your server. See “Configuring RAID” on page 73.
Installing a non-hot-swap hard disk drive
Attention:
Do not open your server or attempt any repair before reading and understanding the “Safety information”
on page iii and “Guidelines” on page 85.
This topic provides instructions on how to install a non-hot-swap hard disk drive.
Before you begin, consider the following hard-disk-drive installation rules:
• Follow the order of the hard-disk-drive bays when installing a hard disk drive. See “Server components”
on page 25 to locate the hard-disk-drive bays in your server.
• For RAID configuration, the hard disk drives must be the same type with the same capacity if they are
within a single RAID array. For more information, see “Configuring RAID” on page 73.
Chapter 6
.
Installing, removing, or replacing hardware
137
Содержание ThinkServer TS430
Страница 16: ...4 ThinkServer TS430 Hardware Maintenance Manual ...
Страница 18: ...6 ThinkServer TS430 Hardware Maintenance Manual ...
Страница 96: ...84 ThinkServer TS430 Hardware Maintenance Manual ...
Страница 192: ...180 ThinkServer TS430 Hardware Maintenance Manual ...
Страница 200: ...188 ThinkServer TS430 Hardware Maintenance Manual ...
Страница 242: ...230 ThinkServer TS430 Hardware Maintenance Manual ...
Страница 249: ...Appendix A Notices 237 ...
Страница 250: ...238 ThinkServer TS430 Hardware Maintenance Manual ...
Страница 262: ...250 ThinkServer TS430 Hardware Maintenance Manual ...
Страница 263: ......
Страница 264: ......