Note:
Use any documentation that comes with the RAID 510i key and follow those instructions in addition to
the instructions in this topic.
To install the RAID 510i key, do the following:
1. Remove all external media from the drives and turn off all attached devices and the server. Then,
disconnect all power cords from electrical outlets and disconnect all cables that are connected to
the server.
2. Prepare your server. See “Removing or extending the server from the rack cabinet” on page 61.
3. Remove the server cover. See “Removing the server cover” on page 61.
4. Locate the ThinkServer RAID 510i Adapter. Then, disconnect any cables from the ThinkServer RAID
510i Adapter.
5. Touch the static-protective package that contains the RAID 510i key to any unpainted surface on the
outside of the server. Then, take the RAID 510i key out of the package.
Note:
Carefully handle the RAID 510i key by its edges.
6. Locate the RAID upgrade key connector on the Lenovo ThinkServer RAID 510i AnyRAID Adapter and
insert the RAID 510i key into the connector. Ensure that the RAID 510i key is securely seated. If
necessary, remove the Lenovo ThinkServer RAID 510i AnyRAID Adapter first before installing the
RAID 510i key. Then, reinstall the Lenovo ThinkServer RAID 510i AnyRAID Adapter. See “Replacing
the AnyRAID adapter” on page 103.
Note:
Ensure that the RAID 510i key is securely seated on the ThinkServer RAID 510i Adapter.
Figure 46. Installing the RAID 510i key
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the installation, go to “Completing the parts replacement” on page 152. Then, the hardware
RAID 5 and RAID 50 levels are available for your server if your server has the required number of hard disk
drives installed. Refer to the
MegaRAID SAS Software User Guide
on the documentation DVD that comes
with your server for information about how to configure the hardware RAID.
Removing the RAID 510i key
Attention:
Do not open your server or attempt any repair before reading and understanding “Safety information”
on page iii and “Guidelines” on page 59.
Chapter 6
.
Replacing hardware
79
Содержание ThinkServer RD550
Страница 1: ...ThinkServer RD550 User Guide and Hardware Maintenance Manual Machine Types 70CV 70CW 70CX and 70CY ...
Страница 14: ...xii ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Страница 18: ...4 ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Страница 20: ...6 ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Страница 72: ...58 ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Страница 178: ...164 ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Страница 191: ......
Страница 192: ......