![Lenovo ThinkServer RD550 Скачать руководство пользователя страница 142](http://html.mh-extra.com/html/lenovo/thinkserver-rd550/thinkserver-rd550_user-manual-and-hardware-maintenance-manual_202917142.webp)
9. Align the holes in the drive tray with the corresponding ones on the new easy-swap drive. Then, install
the four screws to secure the drive to the drive tray.
Figure 102. Installing the drive to the drive tray
10. Slide the new easy-swap drive into the drive bay from the front until it snaps into position, and then
close the handle.
Figure 103. Installing the easy-swap drive
11. Do one of the following:
• If you are installing a drive, save the removed dummy tray in case that you later remove the drive
and need a dummy tray to cover the drive bay.
• If you are replacing a drive and are instructed to return the old drive, follow all packaging instructions
and use any packaging materials that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To configure RAID, go to “Configuring RAID” on page 54.
Installing or replacing a 2.5-inch solid-state drive
You can install or replace a hot-swap solid-state drive without turning off the server, which helps you avoid
significant interruption to the operation of the system.
128
ThinkServer RD550 User Guide and Hardware Maintenance Manual
Содержание ThinkServer RD550
Страница 1: ...ThinkServer RD550 User Guide and Hardware Maintenance Manual Machine Types 70CV 70CW 70CX and 70CY ...
Страница 14: ...xii ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Страница 18: ...4 ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Страница 20: ...6 ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Страница 72: ...58 ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Страница 178: ...164 ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Страница 191: ......
Страница 192: ......