![Lenovo ThinkServer RD550 Скачать руководство пользователя страница 57](http://html.mh-extra.com/html/lenovo/thinkserver-rd550/thinkserver-rd550_user-manual-and-hardware-maintenance-manual_202917057.webp)
Hot-swap-drive status LEDs
Each hot-swap drive has two status LEDs on the front.
1
2
Figure 28. Hot-swap-drive status LEDs
1
Drive activity LED
2
Drive status LED
Description
Off
Off
The drive has failed or is not present.
On, green
Off
The drive is present but not in use.
Blinking, green
Off
The drive is active and data is being
transferred.
On, green
Blinking rapidly (about four flashes
per second), amber
The RAID controller is identifying the
drive.
On, green
On, amber
The RAID array has failed and cannot
be recovered. You need to recreate a
new array.
Blinking, green
Blinking slowly (about one flash per
second), amber
The drive is being rebuilt.
Chapter 3
.