Diagnostic error code
FRU/Action
170-199-XXX
Voltage sensor(s) test failed, cause
unknown
1. See “Undetermined problems” on page 64
2. Flash the system and re-test. See “Updating
(flashing) BIOS from a disc” on page 99
3. Replace component under function test
170-250-XXX 170-251-XXX
Voltage sensor(s) voltage
limit error
1. AC/DC power adapter
2. System board
170-254-XXX
Voltage sensor(s) voltage regulator Module
error
1. Voltage Regulator Module (VRM)
2. Microprocessor
3. System board
175-000-XXX
Thermal sensor(s) test passed
No action
175-0XX-XXX
Thermal sensor(s) failure
1. Flash system
2. System board
175-195-XXX
Thermal sensor(s) test aborted by user
Information only Re-start the test, if necessary
175-196-XXX
Thermal sensor(s) test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
175-197-XXX
Thermal sensor(s) test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility” on page 41
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
175-198-XXX
Thermal sensor(s) test aborted
1. If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test. See “Updating
(flashing) BIOS from a disc” on page 99
3. Go to “Undetermined problems” on page 64
175-199-XXX
Thermal sensor(s) test failed, cause
unknown
1. See “Undetermined problems” on page 64
2. Flash the system and re-test. See “Updating
(flashing) BIOS from a disc” on page 99
3. Replace component under function test
175-250-XXX 175-251-XXX
Thermal sensor(s) limit error
1. Check fans
2. Check AC/DC power adapter voltages
3. Microprocessor
4. System board
185-000-XXX
Asset security test passed
No action
185-XXX-XXX
Asset security failure
1. Flash system
2. System board
185-278-XXX
Asset security chassis intrusion
1. Assure Asset Security Enabled
2. C2 Cover Switch
3. System board
201-000-XXX
System memory test passed
No action
Chapter 7
.
Symptom-to-FRU index
59
Содержание ThinkCentre A58e
Страница 1: ...Hardware Maintenance Manual Machine Types 3425 3980 5214 and 5354 ...
Страница 2: ......
Страница 3: ...Hardware Maintenance Manual Machine Types 3425 3980 5214 and 5354 ...
Страница 15: ...Chapter 2 Safety information 9 ...
Страница 16: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 10 Hardware Maintenance Manual ...
Страница 19: ...Chapter 2 Safety information 13 ...
Страница 20: ...1 2 14 Hardware Maintenance Manual ...
Страница 21: ...Chapter 2 Safety information 15 ...
Страница 27: ...Chapter 2 Safety information 21 ...
Страница 31: ...Chapter 2 Safety information 25 ...
Страница 38: ...32 Hardware Maintenance Manual ...
Страница 42: ...36 Hardware Maintenance Manual ...
Страница 50: ...44 Hardware Maintenance Manual ...
Страница 109: ......
Страница 110: ...Part Number 71Y6308 Printed in USA 1P P N 71Y6308 71Y6308 ...