Diagnostic error code
FRU/Action
000-250-XXX
BIOS APM failure
1. Flash the system. See “Updating (flashing) BIOS
from a disc” on page 99
2. System board
000-270-XXX
BIOS ACPI failure
1. Flash the system. See “Updating (flashing) BIOS
from a disc” on page 99
2. System board
001-000-XXX
System test passed
No action
001-00X-XXX
System error
System board
001-01X-XXX
System error
System board
001-024-XXX
System addressing test failure
System board
001-025-XXX
System checksum value error
1. Flash the system. See “Updating (flashing) BIOS
from a disc” on page 99
2. System board
001-026-XXX
System FLASH data error
1. Flash the system. See “Updating (flashing) BIOS
from a disc” on page 99
2. System board
001-027-XXX
System configuration/setup error
1. Run Setup
2. Flash the system. See “Updating (flashing) BIOS
from a disc” on page 99
3. System board
001-032-XXX
System device controller failure
System board
001-034-XXX
System device buffer allocation failure
1. Reboot the system
2. Flash the system. See “Updating (flashing) BIOS
from a disc” on page 99
3. Run memory test
4. System board
001-035-XXX
System device reset condition detected
System board
001-036-XXX
System register error
System board
001-038-XXX
System extension failure
1. Adapter card
2. System board
001-039-XXX
System DMI data structure error
1. Flash the system. See “Updating (flashing) BIOS
from a disc” on page 99
2. System board
001-040-XXX
System IRQ failure
1. Power-off/on system and re-test
2. System board
001-041-XXX
System DMA failure
1. Power-off/on system and re-test
2. System board
001-195-XXX
System test aborted by user
Information only Re-start the test, if necessary
001-196-XXX
System test halt, error threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
Chapter 7
.
Symptom-to-FRU index
47
Содержание ThinkCentre A58e
Страница 1: ...Hardware Maintenance Manual Machine Types 3425 3980 5214 and 5354 ...
Страница 2: ......
Страница 3: ...Hardware Maintenance Manual Machine Types 3425 3980 5214 and 5354 ...
Страница 15: ...Chapter 2 Safety information 9 ...
Страница 16: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 10 Hardware Maintenance Manual ...
Страница 19: ...Chapter 2 Safety information 13 ...
Страница 20: ...1 2 14 Hardware Maintenance Manual ...
Страница 21: ...Chapter 2 Safety information 15 ...
Страница 27: ...Chapter 2 Safety information 21 ...
Страница 31: ...Chapter 2 Safety information 25 ...
Страница 38: ...32 Hardware Maintenance Manual ...
Страница 42: ...36 Hardware Maintenance Manual ...
Страница 50: ...44 Hardware Maintenance Manual ...
Страница 109: ......
Страница 110: ...Part Number 71Y6308 Printed in USA 1P P N 71Y6308 71Y6308 ...