62
G8264CS Command Reference for ENOS 8.4
A
monitor
port’s
Failover
status
is
Operational
only
if
all
the
following
conditions
hold
true:
Port
link
is
up.
If
Spanning
‐
Tree
is
enabled,
the
port
is
in
the
Forwarding
state.
If
the
port
is
a
member
of
an
LACP
Link
Aggregation
Group
(LAG),
the
port
is
aggregated.
If
any
of
these
conditions
are
not
true,
the
monitor
port
is
considered
to
be
failed.
A
control
port
is
considered
to
be
operational
if
the
monitor
trigger
state
is
Up
.
Even
if
a
port’s
link
status
is
Down
,
Spanning
‐
Tree
status
is
Blocking
,
and
the
LACP
status
is
Not
Aggregated
,
from
a
teaming
perspective
the
port
status
is
Operational
,
since
the
trigger
is
Up
.
A
control
port’s
status
is
displayed
as
Failed
only
if
the
monitor
trigger
state
is
Down
.
Содержание RackSwitch G8264CS
Страница 14: ...14 G8264CS Command Reference for ENOS 8 4 Index 695 ...
Страница 20: ...20 G8264CS Command Reference for ENOS 8 4 ...
Страница 32: ...32 G8264CS Command Reference for ENOS 8 4 ...
Страница 296: ...296 G8264CS Command Reference for ENOS 8 4 ...
Страница 644: ...644 G8264CS Command Reference for ENOS 8 4 ...
Страница 666: ...666 G8264CS Command Reference for ENOS 8 4 ...
Страница 680: ...680 G8264CS Command Reference for ENOS 8 4 ...
Страница 694: ...694 G8264CS Command Reference for ENOS 8 4 ...