4. Check inside the server for any obvious unsafe conditions, such as metal filings, contamination, water or
other liquid, or signs of fire or smoke damage.
5. Check for worn, frayed, or pinched cables.
6. Make sure that the power-supply cover fasteners (screws or rivets) have not been removed or tampered
with.
System reliability guidelines
Review the system reliability guidelines to ensure proper system cooling and reliability.
Make sure the following requirements are met:
• When the server comes with redundant power, a power supply must be installed in each power-supply
bay.
• Adequate space around the server must be spared to allow server cooling system to work properly. Leave
approximately 50 mm (2.0 in.) of open space around the front and rear of the server. Do not place any
object in front of the fans.
• For proper cooling and airflow, refit the server cover before you turn the power on. Do not operate the
server for more than 30 minutes with the server cover removed, for it might damage server components.
• Cabling instructions that come with optional components must be followed.
• A failed fan must be replaced within 48 hours after malfunction.
• A removed hot-swap fan must be replaced within 30 seconds after removal.
• A removed hot-swap drive must be replaced within two minutes after removal.
• A removed hot-swap power supply must be replaced within two minutes after removal.
• Every air baffle that comes with the server must be installed when the server starts (some servers might
come with more than one air baffle). Operating the server with a missing air baffle might damage the
processor.
• All processor sockets must contain either a socket cover or a processor with heat sink.
• When more than one processor is installed, fan population rules for each server must be strictly followed.
Working inside the server with the power on
Guidelines to work inside the server with the power on.
Attention:
The server might stop and data loss might occur when internal server components are exposed
to static electricity. To avoid this potential problem, always use an electrostatic-discharge wrist strap or other
grounding systems when working inside the server with the power on.
• Avoid loose-fitting clothing, particularly around your forearms. Button or roll up long sleeves before
working inside the server.
• Prevent your necktie, scarf, badge rope, or hair from dangling into the server.
• Remove jewelry, such as bracelets, necklaces, rings, cuff links, and wrist watches.
• Remove items from your shirt pocket, such as pens and pencils, in case they fall into the server as you
lean over it.
• Avoid dropping any metallic objects, such as paper clips, hairpins, and screws, into the server.
Handling static-sensitive devices
See this section to handle static-sensitive devices.
150
ThinkSystem SR860 V2Setup Guide
Содержание 7X59
Страница 1: ...ThinkSystem SR860 V2 Setup Guide Machine Types 7X59 and 7X60 ...
Страница 8: ...vi ThinkSystem SR860 V2Setup Guide ...
Страница 50: ...42 ThinkSystem SR860 V2Setup Guide ...
Страница 79: ...5 0 1 2 3 1100 mm C0 C1 Slot 10 6 4 5 6 7 1100 mm C0 C1 Slot 12 Chapter 3 Internal cable routing 71 ...
Страница 132: ...124 ThinkSystem SR860 V2Setup Guide ...
Страница 136: ...128 ThinkSystem SR860 V2Setup Guide ...
Страница 154: ...146 ThinkSystem SR860 V2Setup Guide ...
Страница 250: ...242 ThinkSystem SR860 V2Setup Guide ...
Страница 254: ...246 ThinkSystem SR860 V2Setup Guide ...
Страница 258: ...250 ThinkSystem SR860 V2Setup Guide ...
Страница 259: ......
Страница 260: ......