Specifications
The following information is a summary of the features and specifications of the server. Depending on the
model, some features might not be available, or some specifications might not apply.
Table 1. Specifications, Type 7Z59 and 7Z60
Specification
Description
Dimension
4U server
• Height: 175 mm (6.9 inches)
• Width:
– With rack handles: 482 mm (19.0 inches)
– Without rack handles: 434.4 mm (17.1 inches)
• Depth: 835.9 mm (32.9 inches)
Note:
The depth is measured with rack handles installed.
Weight (depending on the
configuration)
62 kg (136.7 lb) in maximum
Processor (depending on
model)
Supports multi-core Intel Xeon processors, with integrated memory controller and Intel
Mesh UPI (Ultra Path Interconnect) topology.
• Two processor sockets (expandable up to four) with minimal requirement of two
installed on the system board.
• Designed for LGA 4189 sockets
• Scalable up to 28 cores
• Supports 6 UPI links at 10.4 GT/s
Memory
See “Memory module installation rules and order” on page 151 for detailed information
about memory configuration and setup.
• Capacity
– Minimum: 16 GB
– Maximum:
– RDIMM: 3 TB
– 3DS-RDIMM: 6 TB
• Memory module types:
– Double-data-rate 4 (TruDDR4) error correcting code (ECC) 3200 MT/s registered
DIMM (RDIMM) or 3DS RDIMM
– Persistent Memory (PMEM)
• Capacity (depending on the model):
– RDIMM: 16 GB, 32 GB, and 64 GB
– 3DS-RDIMM: 128 GB, 256 GB
– PMEM: 128 GB, 256 GB, and 512 GB
Note:
PMEMs can be mixed with DRAM DIMMs. See “PMEM rules” on page 159
for more information.
• Slots: 24 two-way interleaved slots (expandable to 48)
For a list of supported memory modules, see
https://static.lenovo.com/us/en/
.
Storage expansion
• Forty-eight 2.5-inch drive bays:
– Bay 0 to 23 support SAS/SATA/NVMe drives.
– Bay 24 to 47 support SAS/SATA drives.
Notes:
When the following components are installed in the system, bay 24 to 47
are disabled, and the maximal supported drive quantity is 24.
– PMEMs
– DRAM DIMMs with 64 GB or larger capacity
– Processors with 250 or more watts
• Two 7mm/M.2 drive bays support SAS/SATA/NVMe drives.
4
ThinkSystem SR860 V2Setup Guide
Содержание 7X59
Страница 1: ...ThinkSystem SR860 V2 Setup Guide Machine Types 7X59 and 7X60 ...
Страница 8: ...vi ThinkSystem SR860 V2Setup Guide ...
Страница 50: ...42 ThinkSystem SR860 V2Setup Guide ...
Страница 79: ...5 0 1 2 3 1100 mm C0 C1 Slot 10 6 4 5 6 7 1100 mm C0 C1 Slot 12 Chapter 3 Internal cable routing 71 ...
Страница 132: ...124 ThinkSystem SR860 V2Setup Guide ...
Страница 136: ...128 ThinkSystem SR860 V2Setup Guide ...
Страница 154: ...146 ThinkSystem SR860 V2Setup Guide ...
Страница 250: ...242 ThinkSystem SR860 V2Setup Guide ...
Страница 254: ...246 ThinkSystem SR860 V2Setup Guide ...
Страница 258: ...250 ThinkSystem SR860 V2Setup Guide ...
Страница 259: ......
Страница 260: ......