NMI button
Table 11. NMI button
Button name
Function
Force NMI
button
This button is on the rear of the server. Press this button to force a nonmaskable interrupt to the
processor. You might have to use a pen or the end of a straightened paper clip to press the button.
You can also use it to force a blue screen memory dump (use this button only when you are directed
to do so by Lenovo Support).
Light path button
Table 12. Light path button
Button name
Function
Light path
button
Press this button to light the LEDs on the system board when the power source has been removed
from the server.
SW4
See the following table for SW4 switch block functions.
Table 13. System board SW4 switch block descriptions
Switch
number
Default position
Off
On
1, 16
Off
Host TPM Physical Presence disabled
Host TPM Physical Presence enable
2, 15
Off
PASSWORD_OVERRIDE function disabled
PASSWORD_OVERRIDE function
enabled
3, 14
Off
Serial port message from uEFI
Serial port message from Lenovo
XClarity Controller
4, 13
Off
XCC TPM Physical Presence disabled
XCC TPM Physical Presence
enabled
5, 12
Off
Managing Engine recovery mode disabled
Managing Engine set to recovery
mode
6, 11
Off
Managing Engine security override disabled
Managing Engine security override
enabled
7, 10
Off
Reserved
8, 9
Off
Real time clock reset
Important:
1. Before you change any switch settings or move any jumpers, turn off the server; then, disconnect all
power cords and external cables. Review the information in
http://thinksystem.lenovofiles.com/help/topic/
safety_documentation/pdf_files.html
, “Installation Guidelines” on page 107, “Handling static-sensitive
devices” on page 110, and “Power off the server” on page 12.
2. Any system board switch or jumper block that is not shown in the illustrations in this document are
reserved.
System board LEDs
See this section to locate the LEDs on the system board.
The following illustration shows the light emitting diodes (LEDs) on the system board.
.
37
Содержание 7D31
Страница 1: ...ThinkSystem SR850 V2 Maintenance Manual Machine Types 7D31 and 7D32 ...
Страница 8: ...vi ThinkSystem SR850 V2 Maintenance Manual ...
Страница 52: ...44 ThinkSystem SR850 V2 Maintenance Manual ...
Страница 60: ... Three backplanes on page 57 52 ThinkSystem SR850 V2 Maintenance Manual ...
Страница 70: ...62 ThinkSystem SR850 V2 Maintenance Manual ...
Страница 71: ...Chapter 3 Internal cable routing 63 ...
Страница 78: ...70 ThinkSystem SR850 V2 Maintenance Manual ...
Страница 114: ...106 ThinkSystem SR850 V2 Maintenance Manual ...
Страница 227: ...Figure 129 Installing the air baffle to the system board Chapter 4 Hardware replacement procedures 219 ...
Страница 236: ...Figure 133 System board and expansion board LEDs 228 ThinkSystem SR850 V2 Maintenance Manual ...
Страница 258: ...250 ThinkSystem SR850 V2 Maintenance Manual ...
Страница 260: ...252 ThinkSystem SR850 V2 Maintenance Manual ...
Страница 264: ...256 ThinkSystem SR850 V2 Maintenance Manual ...
Страница 273: ......
Страница 274: ......