4. Make sure that the proper device drivers are installed for the device.
5. Resolve any resource conflicts if running legacy mode (UEFI).
6. Check
http://datacentersupport.lenovo.com
for any tech tips (also known as retain tips or service
bulletins) that might be related to the adapter.
7. Ensure any adapter external connections are correct and that the connectors are not physically
damaged.
A Lenovo optional device that was just installed does not work.
1. Check the XCC event log for any events associated with the device.
2. Make sure that the following conditions are met:
• The device is installed in the correct port.
• The device is designed for the server (see
https://static.lenovo.com/us/en/serverproven/index.shtml
).
• You followed the installation instructions that came with the device, and the device is installed
correctly.
• You have not loosened any other installed devices or cables.
• You updated the configuration information in the Setup utility. Whenever memory or any other device
is changed, you must update the configuration.
3. Reseat the device that you just installed.
4. Replace the device that you just installed.
A Lenovo optional device that worked previously does not work now.
1. Check the XCC event log for any events associated with the device.
2. Make sure that all of the cable connections for the device are secure.
3. Reseat the failing device.
4. If the device comes with test instructions, use those instructions to test the device.
5. If the failing device is a SCSI device, make sure that the following conditions are met:
• The cables for all external SCSI devices are connected correctly.
• The last device in each SCSI chain, or the end of the SCSI cable, is terminated correctly.
• Any external SCSI device is turned on. You must turn on an external SCSI device before you turn on
the server.
6. Replace the failing device.
Power on and power off problems
See this section to resolve issues when powering on or powering off the server.
• “Embedded hypervisor is not in the boot list” on page 246
• “Server does not power on” on page 247
• “Server does not power off” on page 248
• “Unexpected shutdown with LED not lit” on page 248
• “Unexpected shutdown with LED not lit” on page 248
Embedded hypervisor is not in the boot list
Complete the following steps until the problem is resolved:
246
ThinkSystem SR850 V2 Maintenance Manual
Содержание 7D31
Страница 1: ...ThinkSystem SR850 V2 Maintenance Manual Machine Types 7D31 and 7D32 ...
Страница 8: ...vi ThinkSystem SR850 V2 Maintenance Manual ...
Страница 52: ...44 ThinkSystem SR850 V2 Maintenance Manual ...
Страница 60: ... Three backplanes on page 57 52 ThinkSystem SR850 V2 Maintenance Manual ...
Страница 70: ...62 ThinkSystem SR850 V2 Maintenance Manual ...
Страница 71: ...Chapter 3 Internal cable routing 63 ...
Страница 78: ...70 ThinkSystem SR850 V2 Maintenance Manual ...
Страница 114: ...106 ThinkSystem SR850 V2 Maintenance Manual ...
Страница 227: ...Figure 129 Installing the air baffle to the system board Chapter 4 Hardware replacement procedures 219 ...
Страница 236: ...Figure 133 System board and expansion board LEDs 228 ThinkSystem SR850 V2 Maintenance Manual ...
Страница 258: ...250 ThinkSystem SR850 V2 Maintenance Manual ...
Страница 260: ...252 ThinkSystem SR850 V2 Maintenance Manual ...
Страница 264: ...256 ThinkSystem SR850 V2 Maintenance Manual ...
Страница 273: ......
Страница 274: ......