P
IN
L
AYOUT
B-5
8310/8610-8
Connection diagrams
In the following diagrams, the internal circuitry of the module cards is
sketched on the left. The connections to be effected, i.e. the signals,
their direction, and other data, are shown on the right.
A T T E N T I O N
With the P, E, A, W, Y modules you must determine by means of
jumpers if the internal (auxiliary) supply voltage or an external
voltage shall be used for the signals or the encoder supply.
For this reason, check the correct configuration of these jumpers
relative to the desired application. Using a wrong assignment can
cause the module being demaged! The jumpers are set to ‘internal’
(
INT
) at the factory.
N
Terminal
strip
Power supply
for internal circuits and for signals (auxiliary voltages)
mains transformer GEL 89033/89036
115V
230V
0
27V
0
20V
0
P
E
115/230 V~,
50...60 Hz
(3.15/6.3 A)
23...28 V AC
or
23...30 V DC
alternatively:
~ / +
~ / -
16...22 V AC
or
18...30 V DC
*
(2.0/3.15 A)
* With
DC
supply insert wire bridge in terminal strip
ST3
(for devices without certification: ST4)
~ / +
~ / -
1
2
3
4
for auxiliary
voltages and
the supply of
some modules
(e.g. D)
for internal
circuits
(without )
(with )
ST3
(ST4)
E180025I
For the screening and earthing please refer to section 7.2, under ‘EMC measures’.
Содержание GEL 8310
Страница 14: ......
Страница 122: ......
Страница 123: ...TROUBLE SHOOTING 6 8310 8610 8 i 6 Trouble shooting 6 1 6 1 Warning and error messages 6 1 6 2 Fault memory 6 12 ...
Страница 133: ......
Страница 152: ...A 18 STORAGE LOCATIONS FOR MACHINE PARAMETERS 8310 8610 8 Remarks ...
Страница 180: ......
Страница 210: ......
Страница 213: ...FORMS Appendix Y 8310 8610 8 i ...
Страница 226: ...UPDATE INFORMATION Appendix Z 8310 8610 8 i ...