A-22
S
TORAGE LOCATIONS FOR MACHINE PARAMETERS
8310/8610-8
3
10
Set ref.
Setting of the reference measure
Specifies the direction of travel for the setting of the reference measure when
positioning the drive; refer to section 4.6
0
inactive
the setting of the reference measure is disabled
1
forward
the reference measure will be set when moving the drive in
the forward direction
2
reverse
the reference measure will be set when moving the drive in
the reverse direction
3
forw/rev
the reference measure will be set irrespective of the
direction of travel
3
11
Auto cal
Automatic reference search routine
Specifies the direction of motion for setting the reference measure for the auto-
matic reference search routine (auto calibration). This can only be initiated in the
reset state of the unit and if High level is applied to the corresponding stop input;
refer to section 4.6
0
inactive
search routine is disabled
1
autoforw
setting the reference measure in the forward direction
2
auto rev
setting the reference measure in the reverse direction
3
12
Fine
Reference fine signal
Specifies the switching direction of the
reference fine
signal; refer to section 4.6
0
f
edge
negative signal edge (High
→
Low) is evaluated
1
d
edge
positive signal edge (Low
→
High) is evaluated
2
df
edge
both signal edges are evaluated
3
13
Coarse
Reference coarse signal
Specifies the switching state of the
reference coarse
signal; refer to section 4.6
0
low
Low level =^ logical 1
1
high
High level =^ logical 1
Содержание GEL 8310
Страница 14: ......
Страница 122: ......
Страница 123: ...TROUBLE SHOOTING 6 8310 8610 8 i 6 Trouble shooting 6 1 6 1 Warning and error messages 6 1 6 2 Fault memory 6 12 ...
Страница 133: ......
Страница 152: ...A 18 STORAGE LOCATIONS FOR MACHINE PARAMETERS 8310 8610 8 Remarks ...
Страница 180: ......
Страница 210: ......
Страница 213: ...FORMS Appendix Y 8310 8610 8 i ...
Страница 226: ...UPDATE INFORMATION Appendix Z 8310 8610 8 i ...