8
Unit6
Configuration unit 6
GEL 8610
Assignment of 1 axis to the 6th unit (GEL 8610 only)
X
input of the number of axes with the following possibilities:
X = 0: no axis
X = 1: 1 axis (6)
1
6
9
Mem.card
Memory card
GEL 8310
GEL 8610
Activation of a write protection for the optional memory card
0
n.protct
no protection, i.e., data can be stored any time (via
&+;
resp.
>
)
1
protect
data cannot be stored
1
7
10
Card.fkt
Special function with memory card
GEL 8310
GEL 8610
Determines if the equipment-specific axis parameters (AP) are not to be read from
or written to the optional memory card; if the AP have never been stored on a
certain memory card and you try to read the card incl. AP, then the message
mem.card error
is shown
0
excl. AP
axis parameters are not stored/overwritten
1
incl. AP
axis parameters are stored/overwritten
1
8
11
Password
Password inquiry for nominal value
programming
GEL 8310
GEL 8610
Specifies if the programming mode for nominal values is to be accessible via a
password only
0
inactive
no password inquiry
1
active
with password inquiry (define the password at the following
storage location)
Содержание GEL 8310
Страница 14: ......
Страница 122: ......
Страница 123: ...TROUBLE SHOOTING 6 8310 8610 8 i 6 Trouble shooting 6 1 6 1 Warning and error messages 6 1 6 2 Fault memory 6 12 ...
Страница 133: ......
Страница 152: ...A 18 STORAGE LOCATIONS FOR MACHINE PARAMETERS 8310 8610 8 Remarks ...
Страница 180: ......
Страница 210: ......
Страница 213: ...FORMS Appendix Y 8310 8610 8 i ...
Страница 226: ...UPDATE INFORMATION Appendix Z 8310 8610 8 i ...