A-44
S
TORAGE LOCATIONS FOR MACHINE PARAMETERS
8310/8610-8
3
83
84
Reserve
not used for the standard version
--------
3
85
Ref.val2
Value of the 2nd reference measure
Under the precondition that the
reference2/1
signal is active (High level at the
corresponding terminal) this value is loaded into the actual position counter as soon
as the drive exceeds the reference point; the value specified at this location can
also be changed via direct entry in the Automatic mode (refer to storage location
3/9 and section 4.6); 1st reference measure: 3/15
XXXXXXXX
max. 8 digits incl. sign (-) and decimal point; value in actual
measuring units
3
86
Reserve
•
not used
•
for the
•
standard version
3
89
Reserve
--------
3
90
DeltaS=0
Zero Delta_s
Specifies whether the
zero Delta_s
signal shall be active for resetting a contouring
error which has developed during the interrupted (stop) reset state (refer to section
4.5.3)
0
inactive
signal is disabled
1
active
signal is enabled