TS − 3 to 5 Ton R−410A Air Conditioners
ARI RATINGS
1
ARI Standard 210/240 Ratings
E
i
Cooling Capacity
Efficiency
Total Unit
Indoor Unit Model No.
Expansion
Device
Btuh
SEER
EER
Total Unit
Watts
Device
TSA042S4
3.5 TON
Horizontal Indoor Coils + Furnace
Horizontal Coils
+ Furnace
41,000
13.50
11.00
3605
CH33−48C−2F
4
G71MPP−60C−090
2
39L72
41,000
13.50
11.00
3605
CH33−48C−2F
4
G61MPV−60C−090
2
39L72
41,000
13.50
11.50
3565
CH33−48C−2F
4
G71MPP−60C−110
2
39L72
41,000
13.50
11.50
3565
CH33−48C−2F
4
G61MPV−60C−110
2
39L72
41,000
14.00
11.50
3565
CH33−43C−2F
4
G60UHV−60C−090
2
39L72
41,000
14.00
11.50
3565
CH33−43C−2F
4
G60UHV−60C−110
2
39L72
41,000
14.00
11.50
3565
CH33−43C−2F
4
G71MPP−60C−110
2
39L72
41,000
14.00
11.50
3565
CH33−43C−2F
4
G61MPV−60C−110
2
39L72
41,500
13.00
10.90
3805
CH33−43B−2F
4
G61MPV−36B−045
2
39L72
41,500
13.00
11.00
3775
CH33−43B−2F
4
G71MPP−36B−070
2
39L72
41,500
13.00
11.00
3775
CH33−43B−2F
4
G61MPV−36B−070
2
39L72
41,500
13.00
11.00
3775
CH33−43B−2F
4
G61MPV−36B−071
2
39L72
41,500
13.50
11.50
3610
CH33−43B−2F
4
G60UHV−36B−090
2
39L72
41,500
13.50
11.00
3775
CH33−43C−2F
4
G61MPV−60C−091
2
39L72
41,500
13.50
11.00
3775
CH33−49C−2F
4
G71MPP−36C−090
2
39L72
41,500
13.50
11.00
3775
CH33−49C−2F
4
G61MPV−36C−090
2
39L72
41,500
13.50
11.50
3610
CH33−49C−2F
4
G71MPP−60C−090
2
39L72
41,500
13.50
11.50
3610
CH33−49C−2F
4
G61MPV−60C−090
2
39L72
41,500
13.50
11.00
3775
CH33−49C−2F
4
G61MPV−60C−091
2
39L72
41,500
13.50
11.50
3575
CH33−50/60C−2F
4
G71MPP−60C−110
2
39L72
41,500
13.50
11.50
3575
CH33−50/60C−2F
4
G61MPV−60C−110
2
39L72
41,500
13.50
11.50
3615
CH33−50/60C−2F
4
G71MPP−60C−090
2
39L72
41,500
13.50
11.50
3615
CH33−50/60C−2F
4
G61MPV−60C−090
2
39L72
41,500
14.00
11.50
3610
CH33−49C−2F
4
G60UHV−60C−090
2
39L72
41,500
14.00
11.50
3610
CH33−49C−2F
4
G60UHV−60C−110
2
39L72
41,500
14.00
11.50
3610
CH33−49C−2F
4
G61MPV−60C−110
2
39L72
41,500
14.00
11.50
3610
CH33−49C−2F
4
G71MPP−60C−110
2
39L72
41,500
14.00
11.50
3610
CH33−49C−2F
4
G61MPV−60C−111
2
39L72
41,500
14.00
11.50
3575
CH33−50/60C−2F
4
G60UHV−60C−090
2
39L72
Air Handlers
Air Handlers
38,500
12.50
10.50
3675
3
CB29M−46 (Multi−Position)
2
39L72
39,500
13.00
10.90
3605
3
CBX32M−042 (Multi−Position)
2
39L72
39,500
13.00
10.90
3620
3
CBX32M−036 (Multi−Position)
2
39L72
40,000
13.00
11.00
3635
CBX26UH−042 (Up−Flow/Horizontal)
Factory TXV
41,000
13.00
11.00
3715
3
CBX32M−048 (Multi−Position)
2
39L72
41,000
14.00
11.50
3565
4
CBX27UH−048 (Up−Flow / Horizontal)
2
39L72
41,500
14.00
11.50
3590
4
CBX32MV−048 (Multi−Position)
2
39L72
41,500
14.00
11.50
3610
4
CBX27UH−042 (Up−Flow / Horizontal)
Factory TXV
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240; 95
_
F outdoor air temperature, 80
_
F db/67
_
F wb entering evaporator air
with 25 ft. of connecting refrigerant lines.
2
Factory installed RFC or expansion valve on indoor unit MUST be replaced with expansion valve kit (ordered separately) shown.
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (
58M81
) is recommended for field installation.
4
Blower control must be set for a time−off blower delay.