TS − 3 to 5 Ton R−410A Air Conditioners
/ Page 16
ARI RATINGS
1
ARI Standard 210/240 Ratings
E
i
Cooling Capacity
Efficiency
Total Unit
Indoor Unit Model No.
Expansion
Device
Btuh
SEER
EER
Total Unit
Watts
Device
tsa048s4
4 TON
Horizontal Indoor Coils + Furnace (Continued)
Horizontal Coils
+ Furnace
48,000
14.00
11.50
4140
CH33−50/60C−2F
4
G60UHV−60C−110
2
91M02
48,500
13.50
11.00
4410
CH33−49C−2F
4
G61MPV−60C−091
2
91M02
48,500
13.50
11.50
4215
CH33−62D−2F
4
G61MPV−60C−091
2
91M02
48,500
14.00
11.50
4215
CH33−49C−2F
4
G60UHV−60C−090
2
91M02
48,500
14.00
11.50
4215
CH33−49C−2F
4
G60UHV−60C−110
2
91M02
48,500
14.00
11.50
4215
CH33−49C−2F
4
G61MPV−60C−090
2
91M02
48,500
14.00
11.50
4215
CH33−49C−2F
4
G71MPP−60C−090
2
91M02
48,500
14.00
11.50
4215
CH33−49C−2F
4
G61MPV−60C−110
2
91M02
48,500
14.00
11.50
4215
CH33−49C−2F
4
G71MPP−60C−110
2
91M02
48,500
14.00
11.50
4215
CH33−49C−2F
4
G61MPV−60C−111
2
91M02
48,500
14.00
11.50
4140
CH33−50/60C−2F
4
G60UHV−60C−090
2
91M02
48,500
14.00
11.50
4215
CH33−62D−2F
4
G60UHV−60C−090
2
91M02
48,500
14.00
11.50
4215
CH33−62D−2F
4
G60UHV−60C−110
2
91M02
48,500
14.00
11.50
4215
CH33−62D−2F
4
G71MPP−60C−090
2
91M02
48,500
14.00
11.50
4215
CH33−62D−2F
4
G61MPV−60C−090
2
91M02
48,500
14.00
11.50
4215
CH33−62D−2F
4
G71MPP−60C−110
2
91M02
48,500
14.00
11.50
4215
CH33−62D−2F
4
G61MPV−60C−110
2
91M02
48,500
14.00
11.50
4215
CH33−62D−2F
4
G61MPV−60C−111
2
91M02
48,500
14.00
12.00
4045
CH33−62D−2F
4
G60UHV−60D−135
2
91M02
48,500
14.00
11.50
4100
CH33−62D−2F
4
G71MPP−60D−135
2
91M02
48,500
14.00
11.50
4100
CH33−62D−2F
4
G61MPV−60D−135
2
91M02
Air Handlers
Air Handlers
45,000
12.30
10.20
4385
3
CB29M−51 (Multi−Position)
2
91M02
47,500
13.50
11.00
4145
3
CBX32M−048 (Multi−Position)
Factory TXV
47,500
14.00
11.50
4130
4
CBX27UH−048 (Up−Flow / Horizontal)
Factory TXV
47,500
14.00
11.50
4130
4
CBX27UH−060 (Up−Flow / Horizontal)
Factory TXV
48,000
13.50
11.50
4145
4
CBX32MV−048 (Multi−Position)
Factory TXV
48,500
13.50
11.50
4210
3
CBX32M−060 (Multi−Position)
Factory TXV
48,500
14.00
11.50
4150
4
CBX32MV−060 (Multi−Position)
Factory TXV
48,500
14.00
11.50
4190
CBX26UH−048 (Up−Flow/Horizontal)
Factory TXV
49,500
14.00
11.50
4195
3
CBX32M−042 (Multi−Position)
Factory TXV
tsa060s4
5 TON
Up-Flow Indoor Coils
Up−Flow Coils
59,000
13.00
11.00
5300
3, 5
CX34−49C−6F
Factory TXV
60,000
13.00
11.00
5315
3
CX34−60D−6F
Factory TXV
60,500
13.50
11.00
5320
3
CX34−62D−6F
Factory TXV
61,500
13.50
11.50
5335
3
CX34−62C−6F
Factory TXV
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240; 95
_
F outdoor air temperature, 80
_
F db/67
_
F wb entering evaporator air
with 25 ft. of connecting refrigerant lines.
2
Factory installed RFC or expansion valve on indoor unit MUST be replaced with expansion valve kit (ordered separately) shown.
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (
58M81
) is recommended for field installation.
4
Blower control must be set for a time−off blower delay.
5
Most popular indoor coil.