TS − 3 to 5 Ton R−410A Air Conditioners
/ Page 4
FEATURES
Cabinet
Heavy gauge steel cabinet with five station metal wash
process.
Powder paint finish provides superior rust and corrosion
protection.
Painted base section.
Control box is conveniently located with all controls
factory wired.
Corner patch plate allows access to compressor
components.
Drainage holes are provided in base section for moisture
removal.
Refrigerant Line Connections, Electrical Inlets,
Service Valves
Sweat connection suction and liquid lines are located on
corner of unit cabinet.
Fully serviceable brass service valves prevent corrosion
and provide access to refrigerant system. Suction valve
can be fully shut off, while liquid valve may be front seated
to manage refrigerant charge while servicing system.
Refrigerant line connections and field wiring inlets are
located in one central area of cabinet for easy access. See
dimension drawing.
OPTIONS
Hail Guards
Constructed of louvered heavy gauge steel painted to
match cabinet.
Surrounds unit on all four sides to prevent damage to the coil.
Mounting Base
Provides permanent foundation for outdoor units.
High density polyethylene structural material is
lightweight, sturdy, sound absorbing and will withstand the
rigors of the sun, heat, cold, moisture, oil and refrigerant.
Will not mildew or rot.
Can be shipped singly or in packages of 6 to a carton.
Unit Stand-Off Kit
Black high density polyethylene feet are available to raise
unit off of mounting surface away from damaging
moisture.
Four feet are furnished per order number.
CONTROLS
OPTIONS
L Connection
®
Network
See L Connection Engineering Handbook Bulletin in
Controls section for details.
Low Ambient Control
Air conditioners operate satisfactorily down to 45°F
outdoor air temperature without any additional controls.
The Low Ambient Control Kit allows unit operation down
to 30°F.
Freezestat should be installed on compressors equipped
with a low ambient kit.
A compressor lock−out thermostat should be added to
terminate compressor operation below recommended
operation conditions.
Freezestat
Installs on or near the vapor line of the indoor coil or on the
suction line.
Senses suction line temperature and cycles the
compressor off when suction line temperature falls below
it’s setpoint.
Opens at 29°F and closes at 58°F.
Time Delay Relay Kit
Delays the indoor blower−off time during the cooling cycle.
See ARI Rating Tables for usage.
E
F