TS − 3 to 5 Ton R−410A Air Conditioners
ARI RATINGS
1
ARI Standard 210/240 Ratings
Expansion
Cooling Capacity
Efficiency
Total Unit
Indoor Unit Model No.
Expansion
Device
Btuh
SEER
EER
Total Unit
Watts
Device
TSA036S4
3 TON
Horizontal Indoor Coils + Furnace
Horizontal Coils
+ Furnace
33,800
13.50
11.00
3075
CH23−51
4
G61MPV−36B−070
2
37L51
33,800
13.50
11.00
3075
CH23−51
4
G71MPP−36B−070
2
37L51
34,000
13.00
11.00
3090
CH23−51
4
G61MPV−36B−045
2
37L51
34,200
14.00
11.60
2950
CH23−51
4
G60UHV−36B−090
2
37L51
34,800
13.50
11.50
3025
CH33−44/48B−2F
4
G61MPV−36B−070
2
37L51
34,800
13.50
11.50
3025
CH33−44/48B−2F
4
G71MPP−36B−070
2
37L51
35,000
13.50
11.00
3180
CH33−44/48B−2F
4
G61MPV−36B−045
2
37L51
35,200
13.50
11.50
3060
CH33−44/48B−2F
4
G61MPV−36B−071
2
37L51
35,200
14.00
11.60
3035
CH33−44/48B−2F
4
G60UHV−36B−090
2
37L51
35,600
14.00
11.60
3070
CH33−48C−2F
4
G61MPV−60C−090
2
37L51
35,600
14.00
11.60
3070
CH33−48C−2F
4
G61MPV−60C−110
2
37L51
35,600
14.00
11.60
3070
CH33−48C−2F
4
G71MPP−60C−090
2
37L51
35,600
14.00
11.60
3070
CH33−48C−2F
4
G71MPP−60C−110
2
37L51
Air Handlers
Air Handlers
33,600
13.00
11.00
3055
3
CBX32M−030 (Multi−Position)
Factory TXV
34,000
13.00
11.00
3090
CBX26UH−036 (Up−Flow / Horizontal)
Factory TXV
34,200
12.80
10.70
3250
3
CB29M−46 (Multi−Position)
2
37L51
34,200
13.50
11.00
3110
3
CBX32M−036 (Multi−Position)
Factory TXV
34,200
13.50
11.00
3110
3
CBX32M−042 (Multi−Position)
2
37L51
34,600
14.00
11.60
2985
4
CBX32MV−036 (Multi−Position)
Factory TXV
35,200
13.50
11.50
3060
3
CBX32M−048 (Multi−Position)
2
37L51
35,600
14.00
12.00
2965
4
CBX32MV−048 (Multi−Position)
2
37L51
36,200
14.00
12.00
3015
3
CBX27UH−042 (Up−Flow / Horizontal)
2
37L51
TSA042S4
3.5 TON
Up-Flow Indoor Coils
Up−Flow Coils
40,000
13.00
10.80
3700
3
CX34−38A/B−6F
2
39L72
40,000
13.00
10.80
3700
3
CX34−50/60C−6F
2
39L72
40,500
13.00
10.90
3710
3,
5
CX34−43B/C−6F
Factory TXV
41,000
13.00
11.00
3715
3
CX34−49C−6F
2
39L72
Up-Flow Indoor Coils + Furnace
Up−Flow Coils
+ Furnace
40,500
13.00
11.00
3690
CX34−38B−6F
4
G71MPP−36B−070
2
39L72
40,500
13.00
11.00
3690
CX34−38B−6F
4
G61MPV−36B−070
2
39L72
40,500
13.50
11.00
3555
CX34−38B−6F
4
G60UHV−36B−090
2
39L72
40,500
14.00
11.50
3485
CX34−50/60C−6F
4
G60UHV−60C−090
2
39L72
41,000
13.00
11.00
3680
CX34−43B−6F
4
G71MPP−36B−070
Factory TXV
41,000
13.00
11.00
3680
CX34−43B−6F
4
G61MPV−36B−070
Factory TXV
41,000
13.50
11.00
3590
CX34−50/60C−6F
4
G61MPV−60C−090
2
39L72
41,000
13.50
11.00
3590
CX34−50/60C−6F
4
G71MPP−60C−090
2
39L72
41,000
13.50
11.50
3575
CX34−49C−6F
4
G61MPV−60C−090
2
39L72
41,000
13.50
11.50
3575
CX34−49C−6F
4
G71MPP−60C−090
2
39L72
41,000
14.00
11.50
3475
CX34−49C−6F
4
G60UHV−60C−090
2
39L72
41,000
14.00
11.50
3490
CX34−43C−6F
4
G60UHV−60C−090
Factory TXV
Up-Flow Indoor Coils + Furnace
Continued on Next Page
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240; 95
_
F outdoor air temperature, 80
_
F db/67
_
F wb entering evaporator air
with 25 ft. of connecting refrigerant lines.
2
Factory installed RFC or expansion valve on indoor unit MUST be replaced with expansion valve kit (ordered separately) shown.
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (
58M81
) is recommended for field installation.
4
Blower control must be set for a time−off blower delay.
5
Most popular indoor coil.