Page 2
SPECIFICATIONS
Gas
Heating
Performance
Model No. SLP98UH070V36B
SLP98UH090V36C
SLP98UH090V48C
1
AFUE
97.0%
98.0%
97.5%
Maximum
Input - Btuh
66,000
88,000
88,000
Output - Btuh
64,000
85,000
85,000
Temperature rise range - °F
50 - 80
60 - 90
50 - 80
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
3.5 / 10.0
3.5 / 10.0
3.5 / 10.0
Minimum
Input - Btuh
23,000
31,000
31,000
Output - Btuh
22,000
30,000
30,000
Temperature rise range - °F
35 - 65
35 - 65
35 - 65
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
0.5 / 1.5
0.5 / 1.5
0.5 / 1.5
High static - in. w.g.
0.8
0.8
0.8
Connections
in.
Intake / Exhaust Pipe (PVC)
2 / 2
2 / 2
2 / 2
Condensate Drain Trap (PVC pipe) - i.d.
1/2
1/2
1/2
with field supplied (PVC coupling) - o.d.
1/2 slip x 1/2 NPT
1/2 slip x 1/2 NPT
1/2 slip x 1/2 NPT
hose with hose clamp - i.d. x o.d.
1 x 1-1/4
1 x 1-1/4
1 x 1-1/4
Gas pipe size IPS
1/2
1/2
1/2
Indoor
Blower
Wheel nominal diameter x width - in.
10 x 9
10 x 9
11 x 11
Motor output - hp
1/2
1/2
3/4
Tons of add-on cooling
2 - 3
2 - 3.5
2.5 - 4
Air Volume Range - cfm
339 - 1365
520 - 1360
528 - 1770
Electrical
Data
Voltage (Maximum Amps)
120 volts - 60 hertz - 1 phase
Blower motor full load amps
7.7
7.7
10.1
Maximum overcurrent protection
15
15
15
Shipping Data
lbs. - 1 package
138
155
165
NOTE - Filters and provisions for mounting are not furnished and must be field provided.
1
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized
furnaces.
SPECIFICATIONS
Gas
Heating
Performance
Model No. SLP98UH090V60C
SLP98UH110V60C
SLP98UH135V60D
1
AFUE
98.2%
97.5%
97.5%
Maximum
Input - Btuh
88,000
110,000
132,000
Output - Btuh
85,000
106,000
126,000
Temperature rise range - °F
50 - 80
50 - 80
55 - 85
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
3.5 / 10.0
3.5 / 10.0
3.5 / 10.0
Minimum
Input - Btuh
31,000
39,000
46,000
Output - Btuh
30,000
38,000
45,000
Temperature rise range - °F
35 - 65
35 - 65
35 - 65
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
0.5 / 1.5
0.5 / 1.5
0.5 / 1.5
High static - in. w.g.
0.8
0.8
0.8
Connections
in.
Intake / Exhaust Pipe (PVC)
2 / 2
2 / 2
2 / 2
Condensate Drain Trap (PVC pipe) - i.d.
1/2
1/2
1/2
with field supplied (PVC coupling) - o.d.
1/2 slip x 1/2 NPT
1/2 slip x 1/2 NPT
1/2 slip x 1/2 NPT
hose with hose clamp - i.d. x o.d.
1 x 1-1/4
1 x 1-1/4
1 x 1-1/4
Gas pipe size IPS
1/2
1/2
1/2
Indoor
Blower
Wheel nominal diameter x width - in.
11 x 11
11 x 11
11 x 11
Motor output - hp
1
1
1
Tons of add-on cooling
3 - 5
3 - 5
3.5 - 5
Air Volume Range - cfm
375 - 2195
554 - 2125
634 - 2190
Electrical
Data
Voltage (Maximum Amps)
120 volts - 60 hertz - 1 phase
Blower motor full load amps
12.8
12.8
12.8
Maximum overcurrent protection
20
20
20
Shipping Data
lbs. - 1 package
165
175
190
NOTE - Filters and provisions for mounting are not furnished and must be field provided.
1
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized
furnaces.