Page 73
39 - Reinstall gas valve manifold assembly. Reconnect
gas supply line to gas valve.
40 - Reinstall burner box cover.
41 - Reconnect 2-pin plug to gas valve.
42 - Replace the blower compartment access panel.
43 - Refer to instruction on verifying gas and electrical
connections when re-establishing supplies.
44 - Follow lighting instructions to light and operate
furnace for 5 minutes to ensure that heat exchanger
is clean and dry and that furnace is operating
properly.
45 - Replace heating compartment access panel
Cleaning the Burner Assembly
1 -
Turn off electrical and gas power supplies to furnace.
Remove upper and lower furnace access panels.
2 - Disconnect the 2-pin plug from the gas valve.
3 - Remove the burner box cover.
4 - Disconnect the gas supply line from the gas valve.
Remove gas valve/manifold assembly.
5 - Mark and disconnect sensor wire from the sensor.
Disconnect 2-pin plug from the ignitor at the burner
box.
6 - Remove four screws which secure burner box
assembly to vest panel. Remove burner box from the
unit.
7 - Use the soft brush attachment on a vacuum cleaner
to gently clean the face of the burners. Visually
inspect the inside of the burners and crossovers for
any blockage caused by foreign matter. Remove
any blockage.
8 - Reconnect the sensor wire and reconnect the 2-pin
plug to the ignitor wiring harness.
9 - Reinstall the burner box assembly using the existing
four screws. Make sure that the burners line up in
the center of the burner ports.
10 -
Reinstall the gas valve manifold assembly.
Reconnect the gas supply line to the gas valve.
Reinstall the burner box cover.
11 - Reconnect 2-pin plug to gas valve.
12 - Replace the blower compartment access panel.
13 - Refer to instruction on verifying gas and electrical
connections when re-establishing supplies.
14 - Follow lighting instructions to light and operate
furnacefor 5 minutes to ensure that heat exchanger
is cleanand dry and that furnace is operating
properly.
15 - Replace heating compartment access panel.
Burner Box Assembly
burner assembly
rollout switch
ignitor
flame sensor
burner box front cover
(remove screw to open cover)
sight glass
intake air collar
Cover plate
(-090XV60C model only)
FIGURE 61