SPECIFICATIONS
Gas
Heating
Performance
Model No. SLP99UH070XV36B SLP99UH090XV36C SLP99UH090XV48C
1
AFUE
98.1%
98.1%
98.2%
Maximum
Input - Btuh
66,000
88,000
88,000
Output - Btuh
64,000
85,000
85,000
Temperature rise range - °F
50 - 80
60 - 90
50 - 80
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
3.5 / 10.0
3.5 / 10.0
3.5 / 10.0
Minimum
Input - Btuh
23,000
31,000
31,000
Output - Btuh
22,000
30,000
30,000
Temperature rise range - °F
35 - 65
35 - 65
35 - 65
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
0.5 / 1.5
0.5 / 1.5
0.5 / 1.5
High static - in. w.g.
0.8
0.8
0.8
Connections
in.
Intake / ² Exhaust Pipe (PVC)
2 / 2
2 / 2
2 / 2
Gas pipe size IPS
1/2
1/2
1/2
Condensate Drain Trap (PVC pipe) - i.d.
3/4
3/4
3/4
with furnished 90° street elbow
3/4 slip x 3/4 Mipt
3/4 slip x 3/4 Mipt
3/4 slip x 3/4 Mipt
with field supplied (PVC coupling) - o.d.
3/4 slip x 3/4 MPT
3/4 slip x 3/4 MPT
3/4 slip x 3/4 MPT
Indoor
Blower
Wheel nominal diameter x width - in.
10 x 9
10 x 9
11 x 11
Motor output - hp
1/2
1/2
3/4
Tons of add-on cooling
2 - 3
2 - 3.5
2.5 - 4
Air Volume Range - cfm
339 - 1365
520 - 1360
528 - 1770
Electrical Data
Voltage (Maximum Amps)
120 volts - 60 Hertz - 1 phase
Blower motor full load amps
7.7
7.7
10.1
Maximum overcurrent protection
15
15
15
Shipping Data
lbs. - 1 package
139
156
166
NOTE - Filters and provisions for mounting are not furnished and must be field provided.
1
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.
2
2 in. Rubber Flue Coupling is furnished for exhaust pipe connection to unit.
SPECIFICATIONS
Gas
Heating
Performance
Model No. SLP99UH090XV60C SLP99UH110XV60C SLP99UH135XV60D
1
AFUE
99%
98.1%
98.4%
Maximum
Input - Btuh
88,000
110,000
132,000
Output - Btuh
87,000
106,000
128,000
Temperature rise range - °F
50 - 80
50 - 80
55 - 85
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
3.5 / 10.0
3.5 / 10.0
3.5 / 10.0
Minimum
Input - Btuh
31,000
39,000
46,000
Output - Btuh
30,000
38,000
45,000
Temperature rise range - °F
25 - 55
35 - 65
35 - 65
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
0.5 / 1.5
0.5 / 1.5
0.5 / 1.5
High static - in. w.g.
0.8
0.8
0.8
Connections
in.
Intake / ² Exhaust Pipe (PVC)
2 / 2
2 / 2
2 / 2
Gas pipe size IPS
1/2
1/2
1/2
Condensate Drain Trap (PVC pipe) - i.d.
3/4
3/4
3/4
with furnished 90° street elbow
3/4 slip x 3/4 Mipt
3/4 slip x 3/4 Mipt
3/4 slip x 3/4 Mipt
with field supplied (PVC coupling) - o.d.
3/4 slip x 3/4 MPT
3/4 slip x 3/4 MPT
3/4 slip x 3/4 MPT
Indoor
Blower
Wheel nominal diameter x width - in.
11 x 11
11 x 11
11 x 11
Motor output - hp
1
1
1
Tons of add-on cooling
3 - 5
3 - 5
3.5 - 5
Air Volume Range - cfm
380 - 2195
580 - 2125
646 - 2190
Electrical Data
Voltage (Maximum Amps)
120 volts - 60 Hertz - 1 phase
Blower motor full load amps
12.8
12.8
12.8
Maximum overcurrent protection
20
20
20
Shipping Data
lbs. - 1 package
166
176
191
NOTE - Filters and provisions for mounting are not furnished and must be field provided.
1
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.
2
2 in. Rubber Flue Coupling is furnished for exhaust pipe connection to unit.