background image

NOTE: DIAGRAMS AND ILLUSTRATIONS ARE REPRESENTATIVE AND ARE NOT DRAWN TO SCALE.

www.LennoxHearthProducts.com

34

ATTACHINg SAfETy-IN-OPERATION WARNINgS

It is the installer’s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a 

critical step in informing consumers of safe operation of this appliance.

ATTACHINg SAfETy-IN-OPERATION 

WARNINgS

Your fireplace has been furnished with safety instruc-

tion labels that are to be affixed to the operation and 

control points of the fireplace.  A safety instruction label 

should be affixed to the receiver wall switch plate where 

the fireplace is turned on and off (See Figure A) and 

the remote control handheld transmitter (Figure B).  

The warnings should already have been put in place 

when the fireplace initial set-up was completed.  If they 

are not affixed at these spots, locate the multi-lingual 

adhesive labels provided with these instructions and 

proceed as follows:

1.  Locate the wall receiver that controls the fireplace 

(verify the switch operates the fireplace by turn-

ing it on and off).  Clean the wall receiver plate 

thoroughly to remove any dust and oils. Affix the 

label to the surface of the plate of the wall receiver  

that controls the fireplace (Figure A).  Choose 

the language primarily spoken in the home. 

2.  Locate the remote control transmitter and clean 

it thoroughly to remove any dust and oils.  Affix 

the label to the surface of handheld transmitter 

(Figure B).  Choose the language primarily spoken 

in the home. 

3.  If you are unable to locate the labels, please call 

Lennox Hearth Products or your nearest Lennox 

Hearth Products dealer to receive additional 

safety instruction labels free of charge.
Cat. No. H8024 Replacement Label Kit 
LENNOx HEARTH PROdUCTS

1-800-9-LENNOx

Note: English is red text on clear label. French and 

Spanish are white text on black label.

Remote

Off

On

PRG

Figure A 

Figure B

APPOSITION dES MISES EN gARdE RELATIVES  

à LA SéCURITé d’UTILISATION

Votre foyer a été livré avec des étiquettes de sécurité 

qui doivent être collées à côté des dispositifs de 

contrôle du foyer.  Une étiquette de sécurité devrait 

être collée sur la plaque du récepteur mural contrôlant 

l’allumage du foyer (voir Figure A) et sur le boîtier de  

la télécommande (Figure B).  Les mises en garde 

auraient dû être collées au moment de l’installation  

initiale  du  foyer.   Si ce  n’est pas le cas,  prenez les 

étiquettes adhésives multilingues fournies avec ces 

instructions et procédez comme suit:

1.  Repérez le récepteur mural qui contrôle le foyer 

(vérifiez  que  l’interrupteur  contrôle  le  fonction-

nement du foyer en le faisant basculer de Marche 

à Arrêt, et vice-versa).  Nettoyez soigneusement  

la plaque du récepteur mural pour éliminer la 

poussière et les traces de graisse ou d’huile. Collez 

l’étiquette sur la surface de la plaque du récepteur 

mural qui contrôle le foyer (Figure A).  Choisissez 

la langue qui est principalement parlée dans la 

résidence du propriétaire. 

2.  Repérez la télécommande et nettoyez-la soigneuse-

ment pour éliminer la poussière et les traces de 

graisse ou d’huile.  Collez l’étiquette sur le boîtier de 

la télécommande (Figure B).  Choisissez la langue 

qui est principalement parlée dans la résidence du 

propriétaire. 

3.  Si  vous  ne  trouvez  pas  les  étiquettes,  veuillez  

appeler Lennox Hearth Products ou votre distribu-

teur Lennox Hearth Products local pour recevoir 

gratuitement des étiquettes supplémentaires.
Étiquettes de remplacement, n° cat. H8024 
LENNOx HEARTH PROdUCTS

1-800-9-LENNOx

Remarque : Le texte anglais est rouge sur un support 

transparent. Le texte français et espagnol est blanc 

sur un support noir.

COLOCACIóN dE AdVERTENCIAS dE 

SEgURIdAd EN OPERACIóN

Su chimenea incluye etiquetas de instrucciones de 

seguridad que deben colocarse en los puntos de 

operación y control de la chimenea. Se debe colocar 

una etiqueta de instrucciones de seguridad en la placa 

del interruptor de pared del receptor desde el cual se 

enciende y se apaga la chimenea (ver la Figura A)  

y en el transmisor de control remoto (Figura B).  

Las advertencias ya deben haberse colocado cuando 

se completó la instalación inicial de la chimenea. Si 

no están colocadas en estos lugares, encuentre las 

etiquetas adhesivas multilingües proporcionadas con 

estas instrucciones y prosiga de la siguiente manera:

1.  Identifique  el  receptor  de  pared  que  controla  la 

chimenea  (verifique  que  el  interruptor  opera  la 

chimenea encendiéndola y apagándola). Limpie  

bien la placa del receptor de pared para quitar el 

polvo y aceite. Pegue la etiqueta en la superficie 

de la placa del receptor de pared que controla la 

chimenea  (Figura A).  Seleccione el idioma que  

más se habla en la casa. 

2.  Identifique  el  transmisor  de  control  remoto  y  

límpielo bien para quitar el polvo y aceite. Pegue la 

etiqueta en la superficie del transmisor (Figura B)

Seleccione el idioma que más se habla en la casa. 

3.  Si no puede encontrar las etiquetas, sírvase 

llamar a Lennox Hearth Products o al distribuidor  

de Lennox Hearth Products más cercano para 

recibir etiquetas de instrucciones de seguridad 

adicionales gratuitas. 
Juego de etiquetas de repuesto - Nº de cat. H8024 
LENNOx HEARTH PROdUCTS

1-800-9-LENNOx

Nota: La etiqueta en inglés es transparente con texto 

rojo. Las etiquetas en francés y español son negras 

con texto blanco.

SAfETy LABEL  

dIAgRAMS

dIAgRAMAS dE ETIqUETAS  

dE SEgURIdAd

dIAgRAMMES dES éTIqUETTES 

dE SéCURITé

LENNOX HEARTH PRODUCTS  •  RHAPSODY™ LINEAR DIRECT-VENT GAS FIREPLACES (MODEL RHAP54N)  •  INSTALLATION INSTRUCTIONS

ATTACHINg WARNINg 

LABELS

Содержание RHAP54N

Страница 1: ...nity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer ...

Страница 2: ...f manual 506019 84 IMPORTANT Make sure all required accessory kits are available before installing fireplace ___________ Required for complete fireplace instal la tion Refer to the Rhapsody Linear Required and Optional Accessories manual 506019 84 for installation instructions for all required acces sories Optional AccessorIEs Sold separately See Accessories section in fireplace Care and Operation...

Страница 3: ...ous WARNING Improper installation or use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning Do not attempt to alter or modify the construction of the appliance or its components Any modifi cation or alteration may void the warranty certification and Listings of this unit WARNING Any safety screen or guard removed for servicing the appli ance ...

Страница 4: ...ocal codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition or the Canadian Electrical Code CSA C22 1 latest edition Efficiencies Fireplace Model Natural Gas Propane field converted AFUE EnerGuide P4 AFUE EnerGuide P4 RHAP54N 70 2 66 9 69 8 71 8 AFUE Annual Fuel Utilization Efficiency is the recognized U S rating system for the total effi ciency of hea...

Страница 5: ...certain vent runs 16 optional Install reflector from Panel Backlighting Kit Install side panels Install back panel optional Install light assemblies from Panel Backlighting Kit Install Floor Kit Install media required for certain style Floor Kits only Install baffle 26 Install glass door 27 optional Install Bezel 28 12 Verify appliance operation 29 Lighting instructions 30 Air shutter adjustment 3...

Страница 6: ...walls FINISH SURROUND IMPORTANT The factory supplied non com bustible fiber board MUST be installed around the fireplace opening See Page 32 for details MINIMUM CLEARANCES TO COMBUSTIBLES Back 1 2 12 7 mm to unit 0 0 mm to spacers Sides 1 2 12 7 mm to unit 0 0 mm to spacers Top Spacers 0 0 mm Floor 0 0 mm Unit Bottom to Ceiling 65 1651 mm Vent Pipe Top 3 76 mm Sides 1 25 4 mm Bottom 1 25 4 mm SERV...

Страница 7: ...e installing the fireplace the nailing flanges MUST be adjusted according to finish cleanface or surround and wall finish material thickness This is critical to ensure proper fireplace location especially if installing the optional Surround and Bezel See UNIT NAILING FLANGES on Page 9 LENNOX HEARTH PRODUCTS RHAPSODY LINEAR DIRECT VENT GAS FIREPLACES MODEL RHAP54N INSTALLATION INSTRUCTIONS LOCATION...

Страница 8: ...unt appliance on a fully supported platform extending full width and depth of unit B 7 178 5 1 8 130 12 1 8 308 10 1 2 267 Note Illustration provided for dimension information only Fireplace must be adequately framed and supp A Required frame opening width 1 2 of A horizontal centerline of fireplace and vent framing opening B Required frame opening depth with 1 2 13mm thick wall finish material Fo...

Страница 9: ...ling flanges in vertical position for cleanface finish and at 1 2 wall finish depth Cleanface Finish Nailing Flange Settings 1 Leave vertical position of nailing flanges at factory setting see Figure 9 1 DETAIL A 2 If wall finish material is thicker than 1 2 move nailing flanges to applicable horizontal setting Surround Bezel Nailing Flange Settings 1 Move vertical position of Top Nailing Flange U...

Страница 10: ...ank size or other improper installation is NOT covered under the limited warranty On threaded joints use a pipe joint com pound rated for gas Always use propane resistant compounds in propane applica tions Make sure pipe joint compound does NOT get inside the pipe It is recommended to seal around the gas line to prevent cold air leakage Orange Wire from DFC Wire Harness Pressure Regulator Tower Ma...

Страница 11: ... by a qualified installer approved and or licensed as required by the locality In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter Figure 11 3 Gas Stub 1 2 x 3 8 Flare Shut Off Valve 3 8 Flex Tubing 3 8 NPT x 3 8 Flare Fitting Gas Valve Flex Line Connector GAS REQUIREMENTS CONNECTION CONTINUED BURNER Orifice Sizes Sea Level to High Altitude These...

Страница 12: ...apy water is an effective leak test solution it is NOT recom mended because soap residue can corrode pipes and fittings over time 1 Light the appliance refer to the lighting instructions in the Care and Operation Instructions or on the label attached to the door latch 2 Brush all joints and connections with the gas leak test solution If bubbles form or gas odor is detected turn the gas control kno...

Страница 13: ...hed against the adjoining section until fully engaged 3 Twist the section being attached CLOCK WISE running the dimples down and along the channels until seated at the ends of the channels The sections are properly seated when the arrow on one section aligns with the dimple on the other section The unitized design of Secure Vent compo nents will engage and seal both the inner and outer pipe withou...

Страница 14: ... h c n i h t g n e L 2 1 4 2 1 0 1 2 1 2 2 2 1 4 3 2 1 6 4 t n e V f o t h g i e H s n o i t c e S t n e V f o r e b m u N s e h c n i t f 6 7 2 3 2 0 0 0 8 0 8 9 7 2 5 2 3 2 0 0 0 0 6 6 5 0 8 2 5 7 3 3 2 1 0 0 8 0 9 5 9 8 2 5 2 1 4 2 0 1 0 0 6 7 5 1 0 3 5 2 1 5 2 0 0 1 0 6 7 5 0 1 3 5 7 8 5 2 0 0 0 9 0 9 5 5 2 3 5 2 1 7 2 0 0 0 0 7 7 0 3 3 5 7 2 1 0 0 0 7 8 5 4 3 5 7 8 2 0 0 0 0 1 0 0 1 5 9 4 3 5...

Страница 15: ...feet 2 4 m above appliance vent outlet VENT RUN SUPPORT REQUIREMENTS Supporting Vertical Vent Runs Note Proper venting support is very important NEVER use the fireplace to support the weight of the venting Support the vertical portion of the venting system every 8 feet 2 4 m above the fire place vent outlet see Figure 15 1 Use Support Straps cat no SV4 5SU see Accessory section in this manual or c...

Страница 16: ... the flaps inward just enough to slide the assembly up into the vent collar as shown in Figure 16 3 The vent restrictor is held in place by fric tion only The entire vent restrictor assembly must be up inside the vent collar with no portion showing inside the firebox Vent Restrictor Kit provided with fireplace 1 Vent Restrictor Base 2 Wings 4 Screws Figure 16 1 Flaps Figure 16 2 Setting 1 Vent Res...

Страница 17: ...y 2 ApplyabeadofMill PacBlack 700 F high temperature sealant Catalog No 10K81 to the inner adaptor collar approximately 1 2 inch from the end 3 Pull and extend the inner flexible vent pipe 4 Slidetheinnerflexpipeovertheadaptorcol lar Ensure the flexible vent pipe completely engages the adaptor collar to a distance of 1 3 4 inches from the end and that it is free from damage or tears 5 Slide the ge...

Страница 18: ...A mini mum of 6 pipe must be used between the fireplace collar and a 90 elbow For more details see Elbows on Page 14 typical VERTICAL Termination SYSTEMS Typical vertical termination systems are shown in Figures 18 1 18 2 and 18 3 Select the vent design that matches your requirements and make sure the vent run conforms to the rise to run ratios listed in Figure 18 4 If the parameters of your vent ...

Страница 19: ...en the adjusting screw c Apply non combustible caulking silicone caulking is acceptable around entire cir cumference to ensure a water tight seal LENNOX HEARTH PRODUCTS RHAPSODY LINEAR DIRECT VENT GAS FIREPLACES MODEL RHAP54N INSTALLATION INSTRUCTIONS Figure 19 1 Clearance for Multiple Vertical Vent Terminations Min 12 305 mm 12 X Roof Pitch is X 12 2 FT MIN 2 FT MIN Lowest Discharge Opening H H M...

Страница 20: ...or ask your dealer or distributor for more information See the VENTING INSTALLATION section on Pages 13 17 for additional details __________ u Vertical Firestop Spacer must be used anywhere vent pipe passes through a combustible floor or ceiling Horizontal Firestop Spacer must be used anywhere vent pipe passes through a combustible wall For further details see Firestop Spacer Requirements on Page ...

Страница 21: ...e horizontal vent termination must have a minimum 6 152 mm clearance to any overhead combustible projection less than or equal to 2 1 2 64 mm For projections greater than 2 1 2 64 mm see Figure 21 1 For additional vent location restrictions see Page 22 NOTICE Our horizontal terminations meet or exceed industry standards and are designed to per form in a wide range of weather conditions NEVER place...

Страница 22: ... ft 3 ft A A A 9 in U S 12 in Canada V L B J X V A G Inside Corner Detail B C C C 18 Ventilated Soffit Horizontal Termination Detail D Exterior Wall 6 Inside Corner See Item D in the Text Below V P V O N N Q NOTE Local Codes Or Regulations May Require Different Clearances NOTE Location Of The Vent Termination Must Not Interfere With Access To The Electrical Service E LENNOX HEARTH PRODUCTS RHAPSOD...

Страница 23: ...icknesses 2 Attach termination adaptor See Figure 23 2 Attach the termination adaptor provided with the termination to the vent section or telescoping vent section or elbow in the same manner as the other vent components see Attaching Secure Vent Components on Page 13 Note If blown insulation is to be used the Through Wall Shield Kit H5816 MUST be installed 3 Install firestop spacer at exterior wa...

Страница 24: ...l of the outlet 1 5 Connect the ground supply wire to the pigtail lead attached to the outlet s green ground screw 1 6 After wiring is complete replace the cover plate Continued on next page Green Ground Screw Black Hot Side of Receptacle Tab Intact Tab Intact Green White Neutral Side of Receptacle 120 VAC Black Neutral White Ground Green J BOX RECEPTACLE WIRING 120V 60HZ 1PH Junction Box Field Wi...

Страница 25: ... Transmitter 2 8 On the Transmitter press the ON button The Receiver will beep four times to indicate acceptance of the Transmitter s command and set the Receiver to the Transmitter s specific code The system is now initialized WARNING Fire hazard Can cause severe injury or death The receiver causes ignition of the appli ance The appliance can turn on suddenly Keep away from the appliance burner w...

Страница 26: ... WIRING previous two pages before proceeding 1 Install vent restrictor REQUIRED WITH CERTAIN VENT RUNS PROVIDED WITH FIREPLACE If not already done install the provided vent restrictor if required for your specific venting con fig uration before proceeding See Page 16 for complete details 2 Install reflector from Panel Backlighting Kit OPTIONAL See Rhapsody Required and Optional Acces sories manual...

Страница 27: ...stitute the materials used on these doors or replace cracked or broken glass The glass door s of this appliance must onlybereplacedasacompleteunitaspro vided by the manufacturer Do not attempt toreplacebroken crackedorchippedglass separately WARNING Hot GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED Remove glass door assembly and optional bezel only when fireplace is OFF and COLD Do not at...

Страница 28: ...urround Surround installs after wall finish is complete See Pages 32 and 33 Installation of Optional Bezel 1 Hook the bezel upper flange to the top edge of the glass door frame and then swing the lower edge of the bezel toward the door Figure 28 2 2 Gently push the lower edge of the bezel to attach the bezel lower flange to the lower edge of the glass door frame Reverse these steps to remove the b...

Страница 29: ...ting plate are also provided on a tag attached to one of the lower door brackets When first lighting the appliance it will take a few minutes for the gas line to purge itself of air Once purging is complete the pilot and burner will light and operate as indicated in the instruction manual Appliance Checkout To light the burner slide the wall switch to the ON position or use the remote control with...

Страница 30: ...r it call a qualified service technician Do not use tools Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 3 Turn off all electric power to the appliance if servi...

Страница 31: ...here is smoke or soot present first ensure that the flames are not impinging on any of the panels If the panels are properly posi tioned and a sooting condition still exists increase the air shutter opening The more offsets in the vent system the larger the air shutter opening will need to be An appliance operated with the air shutter opened too far may have flames that appear blue and transparent...

Страница 32: ...ES Make sure TOP and BOTTOM Nailing Flanges are attached to fireplace in the correct VERTI CAL position for Surround Bezel Finish and the correct HORIZONTAL position for the wall finish material thickness see Page 9 2 LEFT RIGHT SIDE NAILING FLANGES REMOVE the LEFT and RIGHT SIDE Nail ing Flanges see Figure 32 2 and discard using appropriate disposal methods 3 LEFT RIGHT FILLER ANGLE BRACKETS REMO...

Страница 33: ...ange Bottom edge of Fiber Board abuts lip Combustible Wall Finish Material Top Non Combustible Fiber Board provided with fireplace Wall Stud Insulation and combustible material NOT ALLOWED in clearance zones around vent components Header Header Cleanface Finish Surround Bezel Finish Position of Top and Bottom Nailing Flanges depends on type and thickness of wall finish See UNIT NAILING FLANGES sec...

Страница 34: ...usement la plaque du récepteur mural pour éliminer la poussière et les traces de graisse ou d huile Collez l étiquette sur la surface de la plaque du récepteur mural qui contrôle le foyer Figure A Choisissez la langue qui est principalement parlée dans la résidence du propriétaire 2 Repérezlatélécommandeetnettoyez lasoigneuse ment pour éliminer la poussière et les traces de graisseoud huile Collez...

Страница 35: ... pk H2247 SV4 5VF 10 Firestop Spacer Vertical rigid 1 1 1 spacing 10 pk 96K92 SV4 5SP Support Plate Vent Sections Rigid Listed Secure Vent Components Cat Model Description 17M52 SV4 5HGS 1 TerminationGuard Square 1 pk ref manual 750109M 17M53 SV4 5HGS 12 Termination Guard Horizontal 12 pk ref manual 750109M 87L02 SV4 5HGS Termination Guard for Horizontal Termination Deluxe 1 pk ref manual 750055M ...

Страница 36: ...90 SFKIT36S Horiz Termination forflex with36inch 914 mm compressed flex 77L91 SFKIT48S Horiz Termination forflex with48inch 1219 mm compressed flex 56L74 SFVT30 Vertical Termination for flex flat to 6 12 with flex adaptor section of rigid vent roof support collar assembly roof flashing and storm collar ref manual 750052M 56L75 SFVT45 Vertical Termination for flex 6 12 to 12 12 with flex adaptor se...

Страница 37: ...With proper care and maintenance your appli ance will provide many years of enjoyment If you experience any problem first refer to the troubleshooting guide in this manual If the problem persists or you have any questions about your fireplace system contact your Lennox Hearth Products dealer or distributor Order parts through your Lennox Hearth Products dealer or distributor Parts will be shipped ...

Страница 38: ...Assembly Fireplace Glass Enclosure 54 1 19 H8590 Wrapper Side 1 21 H8591 Wrapper Blockoff 1 23 H8588 Flange Nailing Horizontal Top Bottom 2 24 H8589 Flange Nailing Vertical 2 A 1 H7278 Ground Wire 1 A 2 H7272 DFC Ignition Board 1 A 3 H7270 Gas Valve NG 1 H7271 Gas Valve Propane 1 A 4 H7268 Pilot Assembly NG 1 H7269 Pilot Assembly Propane 1 A 5 H7274 Fan Control Module 1 A 6 80L84 Blower Assembly F...

Страница 39: ...t parts are those listed on the previous page LENNOX HEARTH PRODUCTS RHAPSODY LINEAR DIRECT VENT GAS FIREPLACES MODEL RHAP54N INSTALLATION INSTRUCTIONS 25 1 67 5 D B R E V 00 4 Power 120V Out Fan Aux Out 9 Power 120V Out Fan Aux Out A 1 Power 120V Out Fan Aux Out A 4 Power 120V Out Fan Aux Out A 2 Power 120V Out Fan Aux Out A 3 Power 120V Out Fan Aux Out A 5 A 6 A 10 A 9 A 7 SimFlame A 8 25 1675 D...

Страница 40: ... Hearth Products P N 506023 14 Rev NC 02 2012 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications and prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 1508 Elm Hill Pike Suite 108 Nashville TN 37210 ...

Отзывы: