Controls

H4635

DWTK

Wall Thermostat, Digital

H0251

RCL-STAT

Remote Control, RCL-STAT, Deluxe Thermo-
stat DC 

(ref. form #750129M)

Cat. No. Description

H3134

Cassette Assembly, NG (if LP, Also Requires 75064 

Conversion Kit)

H6030

Burner Pan Assembly

H5922

Pilot Assembly (Convertible NG to LP)

H5942

Gas Control Valve NG (if LP, also Requires H5945 Regu-

lator Kit)

H5943

Regulator NG

H5945

Regulator LP

H5928

Main Burner Orifice #30 NG

H5929

Main Burner Orifice #49 LP

H3121

Blower W/Mounting Brackets

H5875

Blower Snap Switch

H5742

Blower Speed Control (rheostat)

H5744

On/Off Switch

H3119

On/Off Switch Wires

H5745

Piezo Igniter

H3120

Electrical Harness W/Inner Plate

H5859

Log Set

H5863

Bag of Embers / volcanic stone

H5864

Bag of Rockwool

H3101

Firebox Door W/Glass

H3123

Flue Restrictor Plates W/Hardware

Brick Panel Kits 

(ref. form #775269M)

Cat. No.

Model

Description

H7984

RAVL42-STD-BRK

Standard Tan Brick

H7986

RAVL42-ARCHSTONE

Architectural Stone

75356

RAVL42-RED-BRK

Red Brick

Gas Conversion Kits

75095

RAVL42-CK-LP to NG Conversion Kit   LP to NG  

(ref. form #775241M)

75064

RAVL42-CK-NG to LP Conversion Kit   NG to LP  

(ref. form #775250M)

Misc

.

75259

NP-RAVL30/42

Nail Plates (4 x 12) galvanized

75247

Reducer 8”-6 5/8” Reducer (8” to 6-5/8”)

75134

RAVL42-DUCTKT

Ductability Kit 

(ref. form #775272M)

75260

RAVL42-DHHS,

Dog House Heat Shield (for remote thermo-
stat) 

(ref. form #775207M)

ACCESSORIES

REPLACEMENT PARTS - 

Ravelle™ 42 (RAVL42)

Standard Tan Brick

Architectural Stone

Red Brick

Wall

Thermostat

Deluxe 

Remote 

Control

NOTE: The form numbers referenced are the part numbers of the instruction 

sheets included in kits.

Knobs

75169

Gold (set of 2)

75170

Brushed Nickel (set of 2)

75010

Black Nickel (set of 2)

       WARNING 

Failure to position the parts in accordance with these 

diagrams  or  failure  to  use  only  parts  specifically 

approved with this appliance may result in property 

damage or personal injury.

       AVERTISSEMENT 

Risque de dommages ou de blessures si les pièces 

ne sont pas installées conformément à ces schémas 

et ou si des pièces autres que celles spécifiquement 

approuvées avec cet appareil sont utilisées.

Contact an Authorized Lennox Hearth Products dealer to obtain any of 

these parts. Never use substitute materials. Use of non-approved parts 

can result in poor performance and safety hazards.

Содержание Ravelle 42

Страница 1: ...vous trouvez Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournis seur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies...

Страница 2: ...nsiderations 16 Horizontal Vent Installation 17 Vertical Vent Installation 17 Flue Restrictors 18 Vertical Vent Termination Clearances 18 Horizontal Terminations 19 Vertical Terminations 19 Horizontal...

Страница 3: ...ler service agency or the gas supplier WARNING Failure to comply with these installation instructions will result in an improperly installed and operating appliance voiding its warranty Any change to...

Страница 4: ...not be connected to a chimney or flue serving a separate solid fuel burning appliance These appliances are vented gas appliances Do not burn wood or other material in these appliances This appliance i...

Страница 5: ...l building department for requirements in your area SMOKE DETECTORS Certification Gas appliances must be tested and certified by a nationally recognized testing and certification laboratory to ANSI Am...

Страница 6: ...cassette valve and pilot assembly or installing a conversionkit OnlyLennoxHearthProductsconversionkitscanbeusedto convert from NG to LP or LP to NG Contact your Lennox Hearth Products dealer for detai...

Страница 7: ...Mantel The drawing at the lower right shows the minimum distances from the base of the fireplace to combustible mantel and facing material Combustible materials may be placed above and within the sha...

Страница 8: ...the valve wThe electrical power supply wiring should be routed to the right rear of the unit Note The fireplace may be placed directly on wood or non combustible flooring but not on vinyl floor coveri...

Страница 9: ...756 20 3 4 527 47 3 4 1213 35 1 2 902 2 51 34 864 41 1041 38 1 4 972 30 762 43 1092 30 762 3 1 2 89 9 1 2 241 10 3 4 273 72 1 2 1842 6 7 8 175 18 3 16 462 32 5 16 821 3 1 2 89 5 127 6 1 4 159 2 1 4 5...

Страница 10: ...fireplace must be raised the thickness of that hearth extension less the 7 8 22 mm For example if a 2 7 8 73 mm thick cultured stone is to be placed on the floor to serve as the hearth extension then...

Страница 11: ...replace face see below Facing Installation Considerations Non combustible cement board such as Wonderboard Durock or Har dybacker must extend 10 254 mm above the 1 25 mm top reveal and a minimum of 3...

Страница 12: ...75098 Foundry 75035 and Classic Louver 75101 should be used while installing the facing material Templates for the various faces may be purchased from your Lennox Hearth Products dealer or a template...

Страница 13: ...e place face The acid wash will tarnish the face Consult your masonry installer Face Installation A number of different faces are available for the Ravelle 42 gas fire place however all the faces are...

Страница 14: ...red by the approved vent manufacturer Installation other than as instructed by Lennox Hearth Products and vent manufacturers instructions Vent Parts List Direct vent pipe Security Secure Vent may be u...

Страница 15: ...gh Wind 1250 Vinyl Siding Standoff Vent Parts List Vertical Direct vent pipe by Security or Simpson Dura Vent may be used with the Ravelle 42 gas fireplace Please see the lists below to verify the com...

Страница 16: ...orizontal runs of vent must be supported every three feet Wall straps are available for this purpose Pipe Sealing If Security Secure Vent pipe is used then sealant is required at only the first pipe j...

Страница 17: ...inations locations see the diagram on Page 20 9 Allowableclearancesfromtheventpipetocombustiblemateri als must be maintained See Page 7 for these clearances 10 Do not locate the termination cap where...

Страница 18: ...and 23 the burner flame appearance should be evaluated to determined if the flue restrictors need to be set to a different position to adjust for variables in your installation Light the appliance an...

Страница 19: ...of pipe does not exceed those shown below Use the restrictor positions indicated If the fireplace is vented with an elbow directly off the top of the flue collar and three to four feet of horizontal p...

Страница 20: ...ove meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly I Clearance to servic...

Страница 21: ...g 2 on tab An air shield is provided for natural gas use only For LP conversions remove the air shield 5 Place Logs 3 4 and 5 on tab inserts Important Maintain a 1 4 6 4mm air space along the entire l...

Страница 22: ...ff at the electrical panel before any connections are made The loop of wire with the label attached E in Figure 29 may be cut and the wire leads from the wall mounted speed control connected to each e...

Страница 23: ...p is to the right of the inlet tap To check manifold pressure with the fireplace burning at the high burn setting insert a small flat bladed screwdriver into the tap and turn a half turn counter clock...

Страница 24: ...ing air is drawn from a distant room lowering the pressure in that room through the return air duct into the bottom of the fireplace The air then passes through the outer shell and heat exchanger of t...

Страница 25: ...nting Brackets Two White Headed Grille Screws Six Wire Nuts Sixteen Sheet Metal Screws One Wire Clamp The system draws heated air from the Ravelle 42 gas fireplace and moves it with the use of a 150 C...

Страница 26: ...the fan box Since the fan box body is wider than the portion that comes up through the floor an additional piece of floor ing F below should also be cut out for the fan box to slide through Save this...

Страница 27: ...ape at each joint 5 Secure the ducting to prevent sagging Wiring of the Forced Air System Disconnect the electrical supply to the fireplace at the electrical panel prior to wiring the forced air syste...

Страница 28: ...erentcolorsofcovers and knobs come with the kit Select the cover desired and fasten the speed control and cover to the box with the screws supplied Push the desired knob onto the shaft of the speed co...

Страница 29: ...ermostat mural voir Figure B et le cas ch ant sur le bo tier delat l commande FigureC Pouracheverl instal lationcorrectedecefoyer proc dezcommesuitavec les tiquettesadh sivesenlangues trang resfournie...

Страница 30: ...and don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D DO NOT use this appliance if any part has been under water Immediately call...

Страница 31: ...ner gas is burning properly i e no floating lifting or flashback Adjust the primary air shutter s as required Check for proper main burner operation at both high and low flame PILOT ASSEMBLY Thermopil...

Страница 32: ...ed with a 200 CFM blower with a variable speed control and an automatic temperature activated on off snap switch Operation 1 After the fireplace warms up a heat activated switch will turn on the fan A...

Страница 33: ...osition when using the thermostat or remote control and set the thermostat or remote control to the lowest temperature when you wish to use the rocker switch only otherwise one may override the other...

Страница 34: ...ot air outlet vents for lint or other accumulations Never block or restrict vent openings obstruct flow of ventilation air or use vents other than those approved for use with this appliance o Check th...

Страница 35: ...er in place 5 Remove the labeled cover through which the valve control knobs protrude by removing the two allen head screws securing it and slide it off the valve knobs 6 Mark and disconnect wires on...

Страница 36: ...ht pilot If pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap between electrode and p...

Страница 37: ...to NG Conversion Kit LP to NG ref form 775241M 75064 RAVL42 CK NG to LP Conversion Kit NG to LP ref form 775250M Misc 75259 NP RAVL30 42 Nail Plates 4 x 12 galvanized 75247 Reducer 8 6 5 8 Reducer 8 t...

Страница 38: ...AN BRNKL TUSCAN Brushed Nickel 75317 AI42 TUSCAN BKNKL TUSCAN Black Nickel Screen Kit ref form 775289M 75029 Screen Face double Door black 43 1 4 W x 31 7 8 H INSETS Required Includes 1 Top and 1 Bott...

Страница 39: ...CSA P 4 1 02 ET CGA 2 17 M91 CET APPAREIL DOIT TRE INSTALL CONFORM MENT AUX EXIGENCES DES CODES R GIONAUX ET DU CODE D INSTALLATION ANSI NFPA 54 DERNI RE DITION ETATS UNIS OU CAN CGA B149 1 DERNI RE...

Страница 40: ...Pour assistance ou information suppl mentaires contactez un installateur qualifi un agent de service ou un fournisseur de gaz Si vous op rez cet appareil sans qu il ne soit correctement raccord un con...

Страница 41: ...41 NOTES...

Страница 42: ...rts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your Lennox distributor or dealer Parts will be shipped at prevailing prices at time of order When...

Отзывы: