Glass/Door Maintenance

Cleaning:

  When cool, the glass may be cleaned with a clean, soft cloth 

and a household glass cleaner. For cleaning white condensation from 

the interior glass use a gas fireplace glass cleaner available from your 

fireplace dealer. Use of caustic or abrasive cleaners may damage glass. 

Gold  or  nickel  plated 

doors

  must  be  cleaned  with  a  household  glass 

cleaner or denatured alcohol and a soft cloth before firing or fingerprints 

and stains will remain permanently. DO NOT spray commercial glass 

cleaner with ammonia on the door and glass gasket as it may dissolve 

the gasket glue.

Repair:

 If the glass is broken in the glass door, the entire door (metal 

frame, gasket and glass) should be replaced as a unit. This replacement 

glass door is available from your Lennox Hearth Products dealer. Do not 

use substitute parts or materials.  The glass is neo-ceramic and alterna-

tive types must not be used.

NOTE:    BE  CAREFUL  NOT  TO  SPRAY  COMMERCIAL  GLASS 
CLEANER WITH AMMONIA ON GASKET AREA OF DOOR.  AM-
MONIA WILL DISSOLVE GASKET GLUE.

NOTE:  GOLD PLATED SURFACE MUST BE CLEANED WITH GLASS 
CLEANER AND SOFT RAG BEFORE FIRING THE FIRST TIME OR 
FINGER  PRINTS  AND  STAINS  WILL  REMAIN  PERMANENTLY.  
NEVER USE BRASS POLISH TO CLEAN GOLD, THIS WILL RE-
MOVE GOLD PLATING!

Fuel Conversion

Converting the Ravelle™ 42 gas fireplace between natural gas and LP can 

be accomplished by either changing the cassette (valve and pilot assembly) 

or installing a conversion kit (regulator, burner orifice and changing the 

orifice position on the pilot). Only a qualified service technician should 

perform the conversion.

Cassette Removal:

1. Be sure the gas supply is shut off and the fireplace electrical supply 

is shut off at the electrical panel before beginning the conversion. 

Disconnect the gas supply from the fireplace, being careful not to 

apply pressure to the valve in the process.

2. Remove the log set and brick panels (see Brick Panel and Log Set 

Installation).

3. Remove the two allen head screws at the left and right rear of the 

firebox securing the burner support. Lift out the burner and burner 

support.

4. Remove the two allen head screws holding the burner in place.

5. Remove  the  labeled  cover  through  which  the  valve  control  knobs 

protrude by removing the two allen head screws securing it and slide 

it off the valve knobs.

6. Mark and disconnect wires on valve terminals #1 and #3 connected 

to the burner on/off switch, thermostat, or remote control.

7. Remove all the allen head screws (around the perimeter of the cassette 

panel) fastening the cassette to the firebox.

8. Grasp the cassette assembly from inside the firebox and pull it into 

the firebox and out of the fireplace.

9. Install new, converted, or serviced cassette in the reverse order of 

removal. Replace gasket if necessary.

10. All parts and wires must be correctly reinstalled to ensure safe and 

proper operation of the unit.

Conversion Kit:

Please see instructions provided with conversion kit.

Figure 49

Door Latch

Glass Door

Only doors certified with the appliance shall be used.

Seules  des  portes  certifiées  pour  cet  appareil  doivent  être 

utilisées.

CAUTION: DO NOT abuse glass door by striking or slamming 

shut.

Do not remove glass door while the appliance is hot.

       WARNING 

 

Do not attempt to substitute the materials used 

on  these  doors,  or  replace  cracked  or  broken 

glass. 

• Handle  this  glass  with  extreme  care!  Glass  is 

susceptible to damage – Do not scratch or handle 

roughly while reinstalling the glass door frame.

• The glass door(s) of this appliance must only be 

replaced as a complete unit as provided by the 

manufacturer.  Do not attempt to replace broken, 

cracked or chipped glass separately. 

 

Do not attempt to touch the front enclosure glass 

with your hands while the appliance is in use.

       WARNING 

Do  not  operate  appliance  with  the  glass  front 

removed, cracked or broken.

       AVERTISSEMENT 

Ne pas utiliser l'appareil si le panneau frontal en 

verre n'est pas en place, est craqué ou brisé.  

Opening and Removing Door

While holding the door against the firebox, pull each latch forward and up 

- releasing the top of the glass door. To remove the door, grasp it firmly 

with both hands and lift it up so the two tabs at the bottom of the door 

are lifted out of their retaining slots. The glass door is quite heavy, so it 

is important to place it in a secure spot until reinstalled. To reinstall the 

door, the tabs at the bottom of the door must be inserted in the slots 

at the bottom of the firebox. The spring loaded latches must be pulled 

forward and down to apply pressure against the door.

Содержание Ravelle 42

Страница 1: ...vous trouvez Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournis seur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies...

Страница 2: ...nsiderations 16 Horizontal Vent Installation 17 Vertical Vent Installation 17 Flue Restrictors 18 Vertical Vent Termination Clearances 18 Horizontal Terminations 19 Vertical Terminations 19 Horizontal...

Страница 3: ...ler service agency or the gas supplier WARNING Failure to comply with these installation instructions will result in an improperly installed and operating appliance voiding its warranty Any change to...

Страница 4: ...not be connected to a chimney or flue serving a separate solid fuel burning appliance These appliances are vented gas appliances Do not burn wood or other material in these appliances This appliance i...

Страница 5: ...l building department for requirements in your area SMOKE DETECTORS Certification Gas appliances must be tested and certified by a nationally recognized testing and certification laboratory to ANSI Am...

Страница 6: ...cassette valve and pilot assembly or installing a conversionkit OnlyLennoxHearthProductsconversionkitscanbeusedto convert from NG to LP or LP to NG Contact your Lennox Hearth Products dealer for detai...

Страница 7: ...Mantel The drawing at the lower right shows the minimum distances from the base of the fireplace to combustible mantel and facing material Combustible materials may be placed above and within the sha...

Страница 8: ...the valve wThe electrical power supply wiring should be routed to the right rear of the unit Note The fireplace may be placed directly on wood or non combustible flooring but not on vinyl floor coveri...

Страница 9: ...756 20 3 4 527 47 3 4 1213 35 1 2 902 2 51 34 864 41 1041 38 1 4 972 30 762 43 1092 30 762 3 1 2 89 9 1 2 241 10 3 4 273 72 1 2 1842 6 7 8 175 18 3 16 462 32 5 16 821 3 1 2 89 5 127 6 1 4 159 2 1 4 5...

Страница 10: ...fireplace must be raised the thickness of that hearth extension less the 7 8 22 mm For example if a 2 7 8 73 mm thick cultured stone is to be placed on the floor to serve as the hearth extension then...

Страница 11: ...replace face see below Facing Installation Considerations Non combustible cement board such as Wonderboard Durock or Har dybacker must extend 10 254 mm above the 1 25 mm top reveal and a minimum of 3...

Страница 12: ...75098 Foundry 75035 and Classic Louver 75101 should be used while installing the facing material Templates for the various faces may be purchased from your Lennox Hearth Products dealer or a template...

Страница 13: ...e place face The acid wash will tarnish the face Consult your masonry installer Face Installation A number of different faces are available for the Ravelle 42 gas fire place however all the faces are...

Страница 14: ...red by the approved vent manufacturer Installation other than as instructed by Lennox Hearth Products and vent manufacturers instructions Vent Parts List Direct vent pipe Security Secure Vent may be u...

Страница 15: ...gh Wind 1250 Vinyl Siding Standoff Vent Parts List Vertical Direct vent pipe by Security or Simpson Dura Vent may be used with the Ravelle 42 gas fireplace Please see the lists below to verify the com...

Страница 16: ...orizontal runs of vent must be supported every three feet Wall straps are available for this purpose Pipe Sealing If Security Secure Vent pipe is used then sealant is required at only the first pipe j...

Страница 17: ...inations locations see the diagram on Page 20 9 Allowableclearancesfromtheventpipetocombustiblemateri als must be maintained See Page 7 for these clearances 10 Do not locate the termination cap where...

Страница 18: ...and 23 the burner flame appearance should be evaluated to determined if the flue restrictors need to be set to a different position to adjust for variables in your installation Light the appliance an...

Страница 19: ...of pipe does not exceed those shown below Use the restrictor positions indicated If the fireplace is vented with an elbow directly off the top of the flue collar and three to four feet of horizontal p...

Страница 20: ...ove meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly I Clearance to servic...

Страница 21: ...g 2 on tab An air shield is provided for natural gas use only For LP conversions remove the air shield 5 Place Logs 3 4 and 5 on tab inserts Important Maintain a 1 4 6 4mm air space along the entire l...

Страница 22: ...ff at the electrical panel before any connections are made The loop of wire with the label attached E in Figure 29 may be cut and the wire leads from the wall mounted speed control connected to each e...

Страница 23: ...p is to the right of the inlet tap To check manifold pressure with the fireplace burning at the high burn setting insert a small flat bladed screwdriver into the tap and turn a half turn counter clock...

Страница 24: ...ing air is drawn from a distant room lowering the pressure in that room through the return air duct into the bottom of the fireplace The air then passes through the outer shell and heat exchanger of t...

Страница 25: ...nting Brackets Two White Headed Grille Screws Six Wire Nuts Sixteen Sheet Metal Screws One Wire Clamp The system draws heated air from the Ravelle 42 gas fireplace and moves it with the use of a 150 C...

Страница 26: ...the fan box Since the fan box body is wider than the portion that comes up through the floor an additional piece of floor ing F below should also be cut out for the fan box to slide through Save this...

Страница 27: ...ape at each joint 5 Secure the ducting to prevent sagging Wiring of the Forced Air System Disconnect the electrical supply to the fireplace at the electrical panel prior to wiring the forced air syste...

Страница 28: ...erentcolorsofcovers and knobs come with the kit Select the cover desired and fasten the speed control and cover to the box with the screws supplied Push the desired knob onto the shaft of the speed co...

Страница 29: ...ermostat mural voir Figure B et le cas ch ant sur le bo tier delat l commande FigureC Pouracheverl instal lationcorrectedecefoyer proc dezcommesuitavec les tiquettesadh sivesenlangues trang resfournie...

Страница 30: ...and don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D DO NOT use this appliance if any part has been under water Immediately call...

Страница 31: ...ner gas is burning properly i e no floating lifting or flashback Adjust the primary air shutter s as required Check for proper main burner operation at both high and low flame PILOT ASSEMBLY Thermopil...

Страница 32: ...ed with a 200 CFM blower with a variable speed control and an automatic temperature activated on off snap switch Operation 1 After the fireplace warms up a heat activated switch will turn on the fan A...

Страница 33: ...osition when using the thermostat or remote control and set the thermostat or remote control to the lowest temperature when you wish to use the rocker switch only otherwise one may override the other...

Страница 34: ...ot air outlet vents for lint or other accumulations Never block or restrict vent openings obstruct flow of ventilation air or use vents other than those approved for use with this appliance o Check th...

Страница 35: ...er in place 5 Remove the labeled cover through which the valve control knobs protrude by removing the two allen head screws securing it and slide it off the valve knobs 6 Mark and disconnect wires on...

Страница 36: ...ht pilot If pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap between electrode and p...

Страница 37: ...to NG Conversion Kit LP to NG ref form 775241M 75064 RAVL42 CK NG to LP Conversion Kit NG to LP ref form 775250M Misc 75259 NP RAVL30 42 Nail Plates 4 x 12 galvanized 75247 Reducer 8 6 5 8 Reducer 8 t...

Страница 38: ...AN BRNKL TUSCAN Brushed Nickel 75317 AI42 TUSCAN BKNKL TUSCAN Black Nickel Screen Kit ref form 775289M 75029 Screen Face double Door black 43 1 4 W x 31 7 8 H INSETS Required Includes 1 Top and 1 Bott...

Страница 39: ...CSA P 4 1 02 ET CGA 2 17 M91 CET APPAREIL DOIT TRE INSTALL CONFORM MENT AUX EXIGENCES DES CODES R GIONAUX ET DU CODE D INSTALLATION ANSI NFPA 54 DERNI RE DITION ETATS UNIS OU CAN CGA B149 1 DERNI RE...

Страница 40: ...Pour assistance ou information suppl mentaires contactez un installateur qualifi un agent de service ou un fournisseur de gaz Si vous op rez cet appareil sans qu il ne soit correctement raccord un con...

Страница 41: ...41 NOTES...

Страница 42: ...rts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your Lennox distributor or dealer Parts will be shipped at prevailing prices at time of order When...

Отзывы: