All of the below are approximations and examples only. All equipment can differ output by load and system matching. All the attached is meant to show common
examples for safe operation of Lennox equipment. CFM valves are not all exact available targets but will yield a close approximation to all applications.
Example
: ML180UH045V36A (If the target cfm is 407 then a blower running at 400 to 420 CFM would be close)
Table 19. ML180
Model
ML180UH030V36A
ML180UH045V36A
ML180UH070V36A
ML180UH070V36B
Minimum CFM For Zoning
411 CFM @55˚F TR
Output BTU 24,430
407 CFM @55˚F TR
Output BTU 24,000*
589 CFM @55˚F TR
Output BTU 35,000*
589 CFM @55˚F TR
Output BTU 35,000*
Example CFM For Harmony III
565 CFM @40˚F TR
Output BTU 24,430
559 CFM @40˚F TR
Output BTU 24,000*
810 CFM @40˚F TR
Output BTU 35,000*
810 CFM @40˚F TR
Output BTU 35,000*
Maximum CFM
904 CFM @25˚F TR
Output BTU 24,430
1320 CFM @25˚F TR
Output BTU 36,100
1345 CFM @36˚F TR
Output BTU 53,400
1290 CFM @38˚F TR
Output BTU 53,400
Model
ML180UH070V48B
ML180UH090V48B
ML180UH110V60C
Minimum CFM For Zoning
589 CFM @55˚F TR
Output BTU 35,000*
791 CFM @55˚F TR
Output BTU 47,000*
976 CFM @55˚ TR
Output BTU 58,000*
Example CFM For Harmony III
810 CFM @40˚F TR
Output BTU 35,000*
1,109 CFM @40˚F TR
Output BTU 47,000*
1,343 CFM @40˚F TR
Output BTU 58,000
Maximum CFM
1,648 CFM @30˚F TR
Output BTU 53,400
1,740 CFM @38˚F TR
Output BTU 71,500
2,180 CFM @38˚F TR
Output BTU 89,700