8.6. How do I use the Zone Mode? ...........................................................................78
8.7. How are Zones Determined? .............................................................................78
8.8. How do I use the Optional Humiditrol
®
Dehumidification Accessory?
................78
8.9. Enabling and Disabling Humiditrol Setting in Thermostat ..................................78
8.10. Humiditrol User Adjustment is also available under the User Settings.............78
8.11. Owner Reminder! ............................................................................................78
8.12. Thermostat replacement ..................................................................................78
8.13. Maintenance .....................................................................................................78
8.14. Homeowners Zone Information Record ...........................................................79
1.
G
eneral
1.1. Shipping and Packing List
Table 1. Packing List
Quantity
Description
1
Harmony III zoning system unit
1
Discharge Air Sensor
1
Installation Instruction
1
Warranty (W-031-L2-02)
1.2. Acronyms Used
Table 2. Acronyms
Acronym
Description
AC
Air Conditioner
CFM
Cubic Feet per Minute
DAS
Discharge Air Sensor
DF
Down Flow
EDA
Enhanced Dehumidification Accessory
HZA
Humiditrol Zoning Accessory Kit
IFC
Integrated Furnace Control
PIAB
Percentage into Adjustment Band
PWM
Pulse Width Modulated
UH
Up Flow
VSM
Variable Speed Motor
1.3. Additional Parts Required
Table 3. Additional Parts
Quantity
Description
Application
specific
Transformer
Dampers
Thermostats
Balance Point Sensor kit (10Z23)
Pressure switch (For Heat Pump Option): HFC-22 (27W12); HFC-410A (27W13
Tee for vapor line High Pressure Switch (87071)
Defrost Tempering Kit (67M41)
Humiditrol
®
Enhanced Dehumidification Accessory (EDA), EDA-024B (94M41),
EDA-036C (94M42), EDA-060D (94M43)
Humiditrol
®
Zoning Accessory Kit (39W67) (required if Humiditrol
®
EDA, above, is
used)
NOTE:
Due to Lennox’ ongoing commitment to quality, features and options are
subject to change without notice and without incurring liability. Improper
installation, adjustment, alteration, service or maintenance can cause
property damage or personal injury. Installation and service must be
performed by a qualified installer and servicing agency.
1.4. Introduction
IMPORTANT
Variable Speed Blower Motor (VSM) technology is required for use with Harmony
III zoning system.
The Lennox Harmony III zoning system manages the distribution of conditioned
air to specific areas or zones in a house or small commercial building by directing
heated or cooled air to occupied areas without conditioning unused areas. The
system can be used in the following Lennox HVAC system applications:
Table 4. System Applications
Option
Description
1
Variable speed gas furnace used with a 2-stage air conditioner unit. *
2
Variable speed air handler unit (with or without electric heat) used with a 2-stage air
conditioner unit or heat pump. *
3
Variable speed gas furnace used with a 2-stage heat pump (dual fuel).*
*A 1-stage air conditioner unit (heat pump) may be used under specific circumstances as listed in
“Table 8. Lennox AC or Heat Pump Units” on page 7.
Variations on the options described above and included in this document are
cooling-only, hot water coil and cooling system with electric heat applications.
The Harmony III zoning system uses off-the-shelf, single-stage, non-heat pump,
non-power-robbing electronic thermostats and motorized dampers in any of the
applications to control distribution of conditioned air to different zones. This control