background image

10

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

LENNOX HEARTH PRODUCTS  •  MONTEBELLO

® 

 DV GAS FIREPLACES 

(LSM40/45MN-2, LSM40/45MP-2, LSM40/45EN-2)

  •  CARE AND OPERATION INSTRUCTIONS

Only doors certified with the appliance 

shall be used.

Seules des portes certifiées pour cet 

appareil doivent être utilisées.

CAUTION: DO NOT abuse glass door by 

striking or slamming shut.

These  are  direct-vent  appliances.  They  are 

designed to operate only when the front glass 

enclosure panel is installed.  Generally the front 

glass enclosure panel should not be removed 

except to gain access to the components within 

the firebox.  

Removing Glass Enclosure Panel

(see 

Figure 4)

To remove the firescreens, lift up the center of 

the rod to disengage it from the center bracket, 

bend down at center, hold left side with hand 

until it disengages from left side, being careful 

not to scratch paint.  Slowly remove the rod 

from the right side

.

Remove the door modesty shield from the top 

flange glass door by pulling it up firmly with both 

hands until it is disengaged.  Using a phillips 

screwdriver, unfasten two (2) screws located 

at the top of the glass frame.

Tilt the glass frame at the top away from the 

unit.  Lift it carefully off the bottom door track 

and  set  the  door  aside,  protecting  it  from 

inadvertent damage.

Front Glass Enclosure Panel, Removal 

and Installation

To  install  the  front  glass  door  assembly, 

proceed as follows:

1.

 Retrieve the glass door assembly.  Visually 

inspect the gasket on the backside of the 

panel.  The  gasket  surface  must  be  clean, 

free of irregularities and seated firmly.

2. 

Position the door frame in front of the firebox 

opening and engage the bottom flange over 

the rail at the bottom of the firebox opening.

3. 

Swing the door up and back.  Ensure the 

gasket seats evenly as the door draws shut.  

Engage the nut insert and fasten with two 

screws to secure the door.

4. 

Install the door modesty shield on top flange 

glass door as follows:  grab the door modesty 

shield with both hands, with the open hem 

going down and engage it with the upper lip 

of the glass door frame by pushing it all the 

way down.  Make sure the installed shield is 

firmly in place.

5. 

With the firescreen hanging on the screen 

rod, drop in the right side of the rod to the 

right modesty panel.  Then drop in the left 

side of the rod through the slot of the left 

modesty panel.  Make sure that the rod is 

supported by the bracket in the center of the 

fireplace.

Figure 4

Top Flange Glass Door

Frame Assembly

Glass Door Latch (2)

Screws

Firebox Floor

Glass Door Assembly

       WARNING 

Do not operate appliance with 

the glass front removed, cracked 

or broken.

       AVERTISSEMENT 

Ne pas utiliser l'appareil si le 

panneau frontal en verre n'est 

pas  en  place,  est  craqué  ou 

brisé.  

       WARNING 

 

When  reinstalling  the  glass 

door,  the  door  latch  screws 

must  be  securely  tightened 

to  prevent  the  glass  door 

from falling out, which could 

potentially cause damage and 

possible injury.

 

Do not attempt to substitute the 

materials  used  on  this  door, 

or replace cracked or broken 

glass. 

 

Handle this glass with extreme 

care!  Glass  is  susceptible  to 

damage  – Do  not  scratch  or 

handle roughly while reinstall-

ing the glass door frame.

 

The  glass  door  of  this  appli-

ance  must  only  be  replaced 

as a complete unit as provided 

by the manufacturer.  Do not 

attempt  to  replace  broken, 

cracked or chipped glass sepa-

rately. 

 

Do  not  attempt  to  touch  the 

front enclosure glass with your 

hands while the fireplace is in 

use.

       WARNING 

Any  safety  screen  or  guard 

removed for servicing the appli-

ance must be replaced prior to 

operating the appliance.

       AVERTISSEMENT 

Tout écran ou protecteur retiré 

pour  permettre  l’entretien  de 

l’appareil  doit  être  remis  en 

place avant de mettre l’appareil 

en marche.

Содержание Dave Lennox Signature Montebello LSM40EN-2

Страница 1: ...ry or death WARNING AVERTISSEMENT AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS UNE SURFACE VITR E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROI...

Страница 2: ...ts fireplace get EXTREMELY HOT Table of Contents Safety and Your Fireplace 2 Important Safety Information 4 Attaching the Safety in Operation Warnings 5 General Information 6 Maintenance 9 Front Glass...

Страница 3: ...page 5 Lisez la section Informations importantes relatives la s curit page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica...

Страница 4: ...tits les jeunes enfants ou les adultes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent...

Страница 5: ...la y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea Figura A o en el termostato de...

Страница 6: ...dassupple mentalheaters Therefore itisadvisable to have an alternate primary heat source when installed in a dwelling Appliance Installation Service and Maintenance Notices IMPORTANT Improper installa...

Страница 7: ...ust gases are vented through the same direct vent co axial intake exhaust vent system The Millivolt appliances are designed to oper ate on either natural or propane gas and have a millivolt gas contro...

Страница 8: ...nt Access Note Topreventexcessiveresistanceinburner circuit whichcancauseburneroperationprob lems only one burner control switch should be wired to valve Variable Flame Height Adjustment Millivolt And...

Страница 9: ...meandsafecombustion Inspect Wiring Refer to wiring diagrams on Page 15 CAUTION Label all wires prior to discon nection when servicing controls Wiring errorscancauseimproperanddangerous operation Verif...

Страница 10: ...the gasket seats evenly as the door draws shut Engage the nut insert and fasten with two screws to secure the door 4 Installthedoormodestyshieldontopflange glassdoorasfollows grabthedoormodesty shiel...

Страница 11: ...rs of log sets Figure 5 Figure 6 Glowing Embers Rockwool For Propane Gas Only Do Not Place Embers On Main Ports Figure 7 LSM45 2 Shown Mixture Of Volcanic Stone And Vermiculite WARNING DO NOT attempt...

Страница 12: ...With The Grate Pin And Align Groove At The Bottom Of The Log Over The Grate Align Hole At Bottom Of Log 5 Over The Pin On Log 2 Engage Log 7 With The Pin On Log 4 6 5 7 1 2 4 LSM40 2 LSM45 2 Log Plac...

Страница 13: ...ntering the air shutter opening To achieve a warm yellowish orange flame with an orange body that does not soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment G...

Страница 14: ...ING Air shutter adjustment should only be performed by a quali fied professional service technician Ensure that the front glass door assembly is in place and sealed After adjustment Figure 15 Main Bur...

Страница 15: ...A complete parts list is found at the end of this manual Use only parts supplied from the manufacturer Withpropercareandmaintenance yourappli ance will provide many years of enjoyment If you should e...

Страница 16: ...gnal light illuminates briefly to verify that a signal has been sent The Model RCL is designed to operate with all mil livolt ignition systems as well as electronic ignition systems It may be installe...

Страница 17: ...SSION Andiron Door Kits Fits Fireplace Models Catalog No Model Mission Classic LSM40 2 LSM45 2 H2227 AKM LSM H2228 AKC LSM ref Instruction P N 750183M Barrier Screen Kits These Barrier Screen Panel ki...

Страница 18: ...es after the pilot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 5 through 8 If knob does not pop up when released stop and immediately call your serv...

Страница 19: ...onc Allumez imm diatement la veilleuse en d clenchant l allume gaz tincelle en poussant le bouton jusqu ce que la veilleuse s enflamme Continuez de tenir le bouton de r glage enfonc pen dant environ 9...

Страница 20: ...e wall switch to OFF or set the thermostat to the lowest setting if applicable 2 Turn the ON OFF switch to OFF if Step 1 is not applicable 3 Close the main line shut off valve TO TURN OFF GAS TO APPLI...

Страница 21: ...d arr t OFF ou plaez le thermostat plssible si requis 3 Tournezl interrupteur marche arr t laposition arr t Off si l etape 2 est appropriee Cet interrupteur marche arr t devrait toujours tre en posit...

Страница 22: ...ioncan be caused by long lateral runs too many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in pla...

Страница 23: ...t note below IMPORTANT NOTE If an optional remote switch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remot...

Страница 24: ...ires to valve Ensure blue and white 2 wires connection is secure to valve D Air in the gas line Purge gas line of air E Low voltage Test voltage at AC terminals of module for 24 VAC If no voltage repl...

Страница 25: ...k Liner Kit f Black H2219 H4801 H2220 H4803 H2221 H2222 1 1 1 1 1 1 H2223 H4802 H2224 H4804 H2225 H2226 1 1 1 1 1 1 2 Door Modesty Shield H4808 1 H4809 1 3 Log Set Oak H4799 1 H4799 1 3 Log Set Birch...

Страница 26: ...8 8 6 5 9 17 12 4 14 13 HI LO 11 10 22 21 20 15 23 24 25 19 1 1 3 2 1 1 Rustic Pattern Shown NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE LENNOX HEARTH PRODUCTS MONTEBELLO DV GAS FIREPLACES LSM40 45MN...

Страница 27: ...27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE LENNOX HEARTH PRODUCTS MONTEBELLO DV GAS FIREPLACES LSM40 45MN 2 LSM40 45MP 2 LSM40 45EN 2 CARE AND OPERATION INSTRUCTIONS Notes...

Страница 28: ...TIONS Printed in U S A 2005 2011 Lennox Hearth Products P N 875027M Rev H 06 2011 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specification...

Отзывы: