Orifice Sizes -  Sea Level to High Altitude

(All Models): 

These appliances are tested and 

approved for installations at elevations of 0-4500 

feet (0-1372 meters) above sea level using the 

standard burner orifice sizes (marked with an 

"*" in Table 4).  
For higher elevations, contact your gas supplier 

or qualified service technician.
Install the appliance according to the regulations 

of the local authorities having jurisdiction and, 

in the USA, the National Fuel Gas Code NFPA 

54 / ANSI Z223.1 - latest edition or, in Canada, 

the CAN/CSA-B149.1- latest edition.

Burner Orifice Sizes

Elevation 0-4500 feet ( 0-1372 meters)

Model

Nat.Gas

drill size (inches)

Propane

drill size (inches)

LSM40-2 0.1405" (#28)*

• H2286

0.086" (#44)*

• H2287

LSM45-2 0.161" (#20)*

• H2288

0.093" (#42)*

• H4816

Table 4

* Standard size installed at factory

•  Part /Cat. Number

Deration 

At higher elevations, the amount of BTU fuel 

value delivered must be reduced by either using 

gas that has been derated by the gas company 

or by changing the burner orifice to a smaller 

size as regulated by the local authorities having 

jurisdiction and by the (USA) National Fuel Gas 

Code NFPA 54/ANSI Z223.1 - latest edition or, 

in Canada, the CAN/CSA-B149.1 codes - latest 

edition. 

Burn-in Period

During the first few fires of this appliance there 

will  be  some  odor  due  to  the  curing  of  the 

paint and burning off of lubricants used in the 

manufacturing  process.    Depending  on  your 

use, the burn-in period may take a few hours 

or a few days.

KEEP  YOUR  HOUSE  WELL  VENTILATED 

DURING THE CURING PROCESS.  THE ODOR 

AND  HAZE  EMITTED  DURING  THE  CURING 

PROCESS CAN BE QUITE NOTICEABLE AND 

MAY SET OFF A SMOKE DETECTOR. 

Input (BTU/HR) - All Models

Natural Gas

Propane Gas

Model 

No.

Input

(BTU/Hr)

Model 

No.

Input

(BTU/Hr)

LSM40-2

40,000 to

50,000

LSM40-2 40,000 to

50,000

LSM45-2

47,000 to

60,000

LSM45-2 48,000 to

60,000

Table 1

Test  gauge  connections  are  provided  on  the 

front of the millivolt and electronic gas control 

valve, identified IN for the inlet and OUT for the 

manifold side (see Figures 2 and 3 on Page 8

)

.  

The control valves have a 3/8" (10 mm) NPT 

thread inlet and outlet side of the valve.

GENERAL INFORMATION

The fireplace models covered in this manual are 

direct-vent, sealed combustion gas fireplaces 

designed for residential application.  Direct-

vent appliances operate with the combustion 

chamber completely isolated from the indoor 

environment.

All air for combustion is brought in from the 

outside and exhaust gases are vented through 

the same direct-vent, co-axial (intake/exhaust) 

vent system.

The Millivolt appliances are designed to oper-

ate on either natural or propane gas and have 

a millivolt gas control valve with piezo ignition 

system. 

The Electronic appliances are designed to oper-

ate on natural gas only and contain an electronic 

intermittent  pilot  system.  External  electrical 

power is required to operate these units.

These appliances comply with National Safety 

Standards and are tested and listed by OMNI-

Test Laboratories, Inc. (Report No. 116-F-22-5) 

to ANSI Z21.50 (in Canada, CSA-2.22), and CAN/

CGA-2.17-M91 in both the USA and Canada as 

vented gas fireplaces.

The Installation must conform to local codes or, 

in the absence of local codes, with the 

National 

Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest 

edition

, or the 

Natural Gas and Propane Instal-

lation Code, CSA B149.1 - latest edition

.  The 

appliance, when installed, must be electrically 

grounded in accordance with local codes or, in 

the absence of local codes, with the 

National 

Electrical Code, ANSI/NFPA 70 - latest edition

or the 

Canadian Electrical Code, CSA C22.1 - 

latest edition

.

NOTICE: 

A  white  film  may  develop 

on  the  glass  enclosure  panel  during 

the first few fires as part of the burn-in 

process. 

The  first  few  times  you  use  the 

fireplace, clean the glass after each use 

(

AFTER THE GLASS HAS COMPLETELY 

COOLED

);  otherwise,  the  white  film 

will bake onto the glass and become 

difficult to remove.  

See  glass  cleaning  instructions  on 

Page 9.

LENNOX HEARTH PRODUCTS  •  MONTEBELLO

® 

 DV GAS FIREPLACES 

(LSM40/45MN-2, LSM40/45MP-2, LSM40/45EN-2)

  •  CARE AND OPERATION INSTRUCTIONS

BTU Input

Millivolt and electronic models come standard 

with  a  manually-modulated  gas  valve;  flame 

appearance and heat output can be controlled 

at the gas valve. The BTU Input for these ap-

pliances are shown in Table 1.

Gas Pressure

Tables 2 and 3

 

show the appliances' gas pres-

sure requirements.

Inlet Gas Supply Pressure 

(all models)

Fuel #

Minimum

Maximum

Natural Gas

5.5" WC

(1.37 kPa)

10.5" WC

(2.61 kPa)

Propane

11.0" WC

(2.74 kPa)

13.0" WC

(3.23 kPa)

Table 2

Manifold Gas Supply Pressure

(all models)

Fuel #

Low

High

Natural 

Gas

(Lo) 2.2" WC

(0.55 kPa)

(Hi) 3.5" WC

(0.87 kPa)

Propane (Lo) 6.3" WC

(1.57 kPa)

(Hi) 10.0" WC

(2.49 kPa)

Table 3

These appliances must be isolated from 
the gas supply piping system (by closing 
their individual manual shut-off valve) 
during any pressure testing of the gas 
supply piping system at test pressures 
equal to or 

less than

 1/2 psig (3.5 kPa).

These  appliances  and  their  individual 
shut-off  valves  must  be  disconnected 
from the gas supply piping system dur-
ing any pressure testing of that system 
at pressures 

greater than

 1/2 psig (3.5 

kPa).

Содержание Dave Lennox Signature Montebello LSM40EN-2

Страница 1: ...ry or death WARNING AVERTISSEMENT AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS UNE SURFACE VITR E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROI...

Страница 2: ...ts fireplace get EXTREMELY HOT Table of Contents Safety and Your Fireplace 2 Important Safety Information 4 Attaching the Safety in Operation Warnings 5 General Information 6 Maintenance 9 Front Glass...

Страница 3: ...page 5 Lisez la section Informations importantes relatives la s curit page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica...

Страница 4: ...tits les jeunes enfants ou les adultes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent...

Страница 5: ...la y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea Figura A o en el termostato de...

Страница 6: ...dassupple mentalheaters Therefore itisadvisable to have an alternate primary heat source when installed in a dwelling Appliance Installation Service and Maintenance Notices IMPORTANT Improper installa...

Страница 7: ...ust gases are vented through the same direct vent co axial intake exhaust vent system The Millivolt appliances are designed to oper ate on either natural or propane gas and have a millivolt gas contro...

Страница 8: ...nt Access Note Topreventexcessiveresistanceinburner circuit whichcancauseburneroperationprob lems only one burner control switch should be wired to valve Variable Flame Height Adjustment Millivolt And...

Страница 9: ...meandsafecombustion Inspect Wiring Refer to wiring diagrams on Page 15 CAUTION Label all wires prior to discon nection when servicing controls Wiring errorscancauseimproperanddangerous operation Verif...

Страница 10: ...the gasket seats evenly as the door draws shut Engage the nut insert and fasten with two screws to secure the door 4 Installthedoormodestyshieldontopflange glassdoorasfollows grabthedoormodesty shiel...

Страница 11: ...rs of log sets Figure 5 Figure 6 Glowing Embers Rockwool For Propane Gas Only Do Not Place Embers On Main Ports Figure 7 LSM45 2 Shown Mixture Of Volcanic Stone And Vermiculite WARNING DO NOT attempt...

Страница 12: ...With The Grate Pin And Align Groove At The Bottom Of The Log Over The Grate Align Hole At Bottom Of Log 5 Over The Pin On Log 2 Engage Log 7 With The Pin On Log 4 6 5 7 1 2 4 LSM40 2 LSM45 2 Log Plac...

Страница 13: ...ntering the air shutter opening To achieve a warm yellowish orange flame with an orange body that does not soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment G...

Страница 14: ...ING Air shutter adjustment should only be performed by a quali fied professional service technician Ensure that the front glass door assembly is in place and sealed After adjustment Figure 15 Main Bur...

Страница 15: ...A complete parts list is found at the end of this manual Use only parts supplied from the manufacturer Withpropercareandmaintenance yourappli ance will provide many years of enjoyment If you should e...

Страница 16: ...gnal light illuminates briefly to verify that a signal has been sent The Model RCL is designed to operate with all mil livolt ignition systems as well as electronic ignition systems It may be installe...

Страница 17: ...SSION Andiron Door Kits Fits Fireplace Models Catalog No Model Mission Classic LSM40 2 LSM45 2 H2227 AKM LSM H2228 AKC LSM ref Instruction P N 750183M Barrier Screen Kits These Barrier Screen Panel ki...

Страница 18: ...es after the pilot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 5 through 8 If knob does not pop up when released stop and immediately call your serv...

Страница 19: ...onc Allumez imm diatement la veilleuse en d clenchant l allume gaz tincelle en poussant le bouton jusqu ce que la veilleuse s enflamme Continuez de tenir le bouton de r glage enfonc pen dant environ 9...

Страница 20: ...e wall switch to OFF or set the thermostat to the lowest setting if applicable 2 Turn the ON OFF switch to OFF if Step 1 is not applicable 3 Close the main line shut off valve TO TURN OFF GAS TO APPLI...

Страница 21: ...d arr t OFF ou plaez le thermostat plssible si requis 3 Tournezl interrupteur marche arr t laposition arr t Off si l etape 2 est appropriee Cet interrupteur marche arr t devrait toujours tre en posit...

Страница 22: ...ioncan be caused by long lateral runs too many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in pla...

Страница 23: ...t note below IMPORTANT NOTE If an optional remote switch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remot...

Страница 24: ...ires to valve Ensure blue and white 2 wires connection is secure to valve D Air in the gas line Purge gas line of air E Low voltage Test voltage at AC terminals of module for 24 VAC If no voltage repl...

Страница 25: ...k Liner Kit f Black H2219 H4801 H2220 H4803 H2221 H2222 1 1 1 1 1 1 H2223 H4802 H2224 H4804 H2225 H2226 1 1 1 1 1 1 2 Door Modesty Shield H4808 1 H4809 1 3 Log Set Oak H4799 1 H4799 1 3 Log Set Birch...

Страница 26: ...8 8 6 5 9 17 12 4 14 13 HI LO 11 10 22 21 20 15 23 24 25 19 1 1 3 2 1 1 Rustic Pattern Shown NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE LENNOX HEARTH PRODUCTS MONTEBELLO DV GAS FIREPLACES LSM40 45MN...

Страница 27: ...27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE LENNOX HEARTH PRODUCTS MONTEBELLO DV GAS FIREPLACES LSM40 45MN 2 LSM40 45MP 2 LSM40 45EN 2 CARE AND OPERATION INSTRUCTIONS Notes...

Страница 28: ...TIONS Printed in U S A 2005 2011 Lennox Hearth Products P N 875027M Rev H 06 2011 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specification...

Отзывы: