LENNOX HEARTH PRODUCTS  •  MONTEBELLO

® 

 DV GAS FIREPLACES 

(LSM40/45MN-2, LSM40/45MP-2, LSM40/45EN-2)

  •  CARE AND OPERATION INSTRUCTIONS

SYMPTOM

POSSIBLE CAUSES

CORRECTIVE ACTION

1.

  Spark igniter will not light pilot after 

repeated triggering of igniter button.

  WARNING: if the pilot will not light 

after 1 minute of attempting, wait 

for at least 5 minutes for gas to 

clear before attempting again.

A.

  Defective igniter

  (no spark at electrode).

Check for spark at electrode and pilot; if no spark and 

electrode wire is properly connected, replace igniter.

B.

  Defective or misaligned electrode at pilot 

(spark at electrode).

Using a match, light pilot. If pilot lights, turn off pilot 

and trigger the igniter button again. If pilot lights, an 

improper gas mixture caused the bad lighting and a 

longer purge period is recommended. If pilot will not 

light – check gap at electrode and pilot – should be 1/8" 

to have a strong spark. If gap measures 1/8", replace 

pilot (see Figures 16 or 17 

on 

Page 14).

C.

  Gas supply pressure errant.

Check inlet gas pressure. It should be within the limits 

as marked on the rating plate.

D.

  Pilot orifice plugged.

Clean or replace pilot orifice.

2.

  Pilot will not stay lit after 

carefully following the lighting 

instructions.

A.

  Defective pilot generator 

(thermocouple)

Check pilot flame, it must impinge on thermocouple  

(see  Figures  16  or  17 

on 

Page  14

). 

Clean  and/or 

adjust  pilot  for  maximum  flame  impingement  on 

thermocouple. Ensure that the connection between 

the valve and thermocouple are tight and secure.

3.

  Pilot burning, no gas to burner, Valve 

knob “ON,” and the (standard) burner 

OFF/ON switch is “ON."  Read impor-

tant note below.

  IMPORTANT NOTE: If an optional 

*remote switch is used for burner 

operation, if the standard burner 

OFF/ON switch is still installed on 

appliance it must be in the "OFF" 

position.

  *Optional remote switch kits - wall 

switch, wall thermostat or remote 

control.

A.

  Wall switch or wires defective.

Check wall switch and wires for proper connections. 

Jumper wire across terminals at wall switch, if burner 

comes on, replace defective wall switch. If okay, jumper 

wires across wall switch wires at valve, if burner comes 

on, wires are faulty or connections are bad.

B.

  Thermopile may not be generating suf-

ficient millivolts.

Check thermopile with millivolt meter. Take reading 

at  thermopile  terminals  of  gas  valve.  Should  read 

325  millivolts  minimum  with  optional  wall  switch 

“OFF.” Replace faulty thermopile if reading is below 

specified minimum.

C.

  Plugged burner orifice.

Check burner orifice for blockage and remove.

D.

  OFF/ON Switch & *Remote Switch are in 

the "ON" position resulting in excessive 

resistance.

When turning on the burner using a *remote switch, 

ensure that the standard OFF/ON switch is in the "OFF" 

position.  If both switches are in the ON position, it 

may result in excessive resistance (& millivolt drain-

age) and the burner may not come on.

4.

  Frequent pilot/burner outage prob-

lem.

A.

  Pilot flame may be too low or blowing 

(high) causing the pilot/valve safety to drop 

out.

Clean and/or adjust pilot flame for maximum flame 

impingement on thermocouple  (see Figures 16 or 

17 

on 

Page 14

).

TROUBLESHOOTING GUIDE - MILLIVOLT GAS CONTROL SYSTEM 

Note: Before troubleshooting the gas control system, make sure the external gas shut off valve, located at gas supply inlet, (and wall switch, if 

applicable), is in the “ON” position.

Important: Valve system troubleshooting should only be accomplished by a qualified service technician.

Содержание Dave Lennox Signature Montebello LSM40EN-2

Страница 1: ...ry or death WARNING AVERTISSEMENT AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS UNE SURFACE VITR E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROI...

Страница 2: ...ts fireplace get EXTREMELY HOT Table of Contents Safety and Your Fireplace 2 Important Safety Information 4 Attaching the Safety in Operation Warnings 5 General Information 6 Maintenance 9 Front Glass...

Страница 3: ...page 5 Lisez la section Informations importantes relatives la s curit page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica...

Страница 4: ...tits les jeunes enfants ou les adultes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent...

Страница 5: ...la y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea Figura A o en el termostato de...

Страница 6: ...dassupple mentalheaters Therefore itisadvisable to have an alternate primary heat source when installed in a dwelling Appliance Installation Service and Maintenance Notices IMPORTANT Improper installa...

Страница 7: ...ust gases are vented through the same direct vent co axial intake exhaust vent system The Millivolt appliances are designed to oper ate on either natural or propane gas and have a millivolt gas contro...

Страница 8: ...nt Access Note Topreventexcessiveresistanceinburner circuit whichcancauseburneroperationprob lems only one burner control switch should be wired to valve Variable Flame Height Adjustment Millivolt And...

Страница 9: ...meandsafecombustion Inspect Wiring Refer to wiring diagrams on Page 15 CAUTION Label all wires prior to discon nection when servicing controls Wiring errorscancauseimproperanddangerous operation Verif...

Страница 10: ...the gasket seats evenly as the door draws shut Engage the nut insert and fasten with two screws to secure the door 4 Installthedoormodestyshieldontopflange glassdoorasfollows grabthedoormodesty shiel...

Страница 11: ...rs of log sets Figure 5 Figure 6 Glowing Embers Rockwool For Propane Gas Only Do Not Place Embers On Main Ports Figure 7 LSM45 2 Shown Mixture Of Volcanic Stone And Vermiculite WARNING DO NOT attempt...

Страница 12: ...With The Grate Pin And Align Groove At The Bottom Of The Log Over The Grate Align Hole At Bottom Of Log 5 Over The Pin On Log 2 Engage Log 7 With The Pin On Log 4 6 5 7 1 2 4 LSM40 2 LSM45 2 Log Plac...

Страница 13: ...ntering the air shutter opening To achieve a warm yellowish orange flame with an orange body that does not soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment G...

Страница 14: ...ING Air shutter adjustment should only be performed by a quali fied professional service technician Ensure that the front glass door assembly is in place and sealed After adjustment Figure 15 Main Bur...

Страница 15: ...A complete parts list is found at the end of this manual Use only parts supplied from the manufacturer Withpropercareandmaintenance yourappli ance will provide many years of enjoyment If you should e...

Страница 16: ...gnal light illuminates briefly to verify that a signal has been sent The Model RCL is designed to operate with all mil livolt ignition systems as well as electronic ignition systems It may be installe...

Страница 17: ...SSION Andiron Door Kits Fits Fireplace Models Catalog No Model Mission Classic LSM40 2 LSM45 2 H2227 AKM LSM H2228 AKC LSM ref Instruction P N 750183M Barrier Screen Kits These Barrier Screen Panel ki...

Страница 18: ...es after the pilot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 5 through 8 If knob does not pop up when released stop and immediately call your serv...

Страница 19: ...onc Allumez imm diatement la veilleuse en d clenchant l allume gaz tincelle en poussant le bouton jusqu ce que la veilleuse s enflamme Continuez de tenir le bouton de r glage enfonc pen dant environ 9...

Страница 20: ...e wall switch to OFF or set the thermostat to the lowest setting if applicable 2 Turn the ON OFF switch to OFF if Step 1 is not applicable 3 Close the main line shut off valve TO TURN OFF GAS TO APPLI...

Страница 21: ...d arr t OFF ou plaez le thermostat plssible si requis 3 Tournezl interrupteur marche arr t laposition arr t Off si l etape 2 est appropriee Cet interrupteur marche arr t devrait toujours tre en posit...

Страница 22: ...ioncan be caused by long lateral runs too many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in pla...

Страница 23: ...t note below IMPORTANT NOTE If an optional remote switch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remot...

Страница 24: ...ires to valve Ensure blue and white 2 wires connection is secure to valve D Air in the gas line Purge gas line of air E Low voltage Test voltage at AC terminals of module for 24 VAC If no voltage repl...

Страница 25: ...k Liner Kit f Black H2219 H4801 H2220 H4803 H2221 H2222 1 1 1 1 1 1 H2223 H4802 H2224 H4804 H2225 H2226 1 1 1 1 1 1 2 Door Modesty Shield H4808 1 H4809 1 3 Log Set Oak H4799 1 H4799 1 3 Log Set Birch...

Страница 26: ...8 8 6 5 9 17 12 4 14 13 HI LO 11 10 22 21 20 15 23 24 25 19 1 1 3 2 1 1 Rustic Pattern Shown NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE LENNOX HEARTH PRODUCTS MONTEBELLO DV GAS FIREPLACES LSM40 45MN...

Страница 27: ...27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE LENNOX HEARTH PRODUCTS MONTEBELLO DV GAS FIREPLACES LSM40 45MN 2 LSM40 45MP 2 LSM40 45EN 2 CARE AND OPERATION INSTRUCTIONS Notes...

Страница 28: ...TIONS Printed in U S A 2005 2011 Lennox Hearth Products P N 875027M Rev H 06 2011 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specification...

Отзывы: