![Lennox CLIMATIC series Скачать руководство пользователя страница 85](http://html1.mh-extra.com/html/lennox/climatic-series/climatic-series_user-manual_1877193085.webp)
Menu
Description
4th
digit
3rd
digit
2nd
digit
1st
digit
R/W/Z Min
Std
Max
2191 value
of
the
signal,
be
‐
1
b1
Be.1
‐
B1
R
‐
5
0
5
2192 value
of
the
signal,
be
‐
1
b2
Be.1
‐
B2
R
‐
5
0
5
2193 value
of
the
signal,
be
‐
1
b3
Be.1
‐
B3
R
‐
5
0
5
2194 value
of
the
signal,
be
‐
1
b4
Be.1
‐
B4
R
‐
5
0
5
2211 value
of
the
outside
temperature
Outside
R
‐
99,9
0
99,9
2212 Origin
of
the
Value
(BM,
BE,
BUS,
Mast/Slav
or
BMS)
From
R
23
23
62
2213 value
of
the
room
temperature
Room
R
‐
99,9
0
99,9
2214 Origin
of
the
Value
(BM,
BE,
BUS,
Mast/Slav
or
BMS)
From
R
23
23
62
2215 value
of
the
supply
temperature
Supply
R
‐
99,9
0
99,9
2216 value
of
the
return
temperature
Return
R
‐
99,9
0
99,9
2221 value
of
the
room
temperature
Temp.
R
‐
99,9
0
99,9
2222 customer
(dc/dm)
set
point
Sp
Cust.
R/W
8
20,5
35
2223 set
value
of
cooling
mode
Set
Cool.
R
8
19
35
2224 set
value
of
heating
mode
Set
Heat.
R
8
22
35
2225 states
of
cooling
mode
State.C
R
23
23
62
2226 states
of
heating
mode
State.H
R
23
23
62
2227 power
factor
of
cooling
mode
Pf.Cool.
R
0
0
100
2228 power
factor
of
heating
mode
Pf.Heat.
R
0
0
100
2231 value
of
the
supply
temperature
Temp.
R
‐
99,9
0
99,9
2232 Blowing
air
temperature
set
point
Setting
R
1
20,5
70
2233 activation
of
the
smoothing
function
of
temperature
Smooth
R/Z
0
0
1
2234 count
value
of
cooling
operating
time
Time.Cool
R
0
0
9999
2235 count
value
of
heating
operating
time
Time.Heat
R
0
0
9999
2241 Dynamic
set
point
(cooling
setpoint
offset
according
to
outside
temperature)
Sp.Dyna.
R/W/Z
0
20
20
2242 set
point
of
cooling
mode
Sp.Cool.
R/W/Z
8
19
35
2243 set
point
of
heating
mode
Sp.Heat.
R/W/Z
8
22
35
2244 outdoor
temperature
low
threshold
for
room
temperature
setpoint
slope
Out.Low
R/W
‐
20
0
50
2245 room
temp
setpoint
offset
according
to
low
outdoor
air
temp
Coef.Low
R/W
‐
50
0
50
2246 outdoor
temperature
high
threshold
for
slope
on
the
room
temperature
setpoint
Out.High
R/W
‐
20
30
50
2247 room
temp
setpoint
offset
according
to
high
outdoor
air
temp
Coef.High
R/W
‐
50
0
50
2248 room
temperature
threshold
for
unloading
cooling
mode
Limit
C.
R/W
0
0
40
2249 room
temperature
threshold
for
unloading
heating
mode
Limit
H.
R/W
0
40
40
2251 low
limit
threshold
in
cooling
mode
Lim.Cool
R/W
4
12
38
2252 high
limit
threshold
in
heating
mode
Lim.Heat
R/W
4
38
38
2253 offset
for
high
limit
threshold
in
cooling
mode
Adj.Cool
R/W
‐
5
0
5
2254 offset
for
low
limit
threshold
in
heating
mode
Adj.Heat
R/W
‐
5
0
5
2255 outdoor
temperature
low
threshold
for
slope
on
the
supply
temperature
setpoint
Out.Low
R/W
‐
20
0
50
2256 coefficient
of
the
low
outside
temperature
for
the
slope
of
the
supply
temperature
setpoint
Coef.Low
R/W
‐
50
0
50
2257 outdoor
temperature
high
threshold
for
slope
on
the
supply
temperature
setpoint
Out.High
R/W
‐
20
30
50
2258 coefficient
of
the
high
outside
temperature
for
the
slope
of
the
supply
temperature
setpoint
Coef.High
R/W
‐
50
0
50
2261 value
of
the
outside
humidity
Outside
R
0
0
100
2262 calculated
value
of
the
outside
absolute
humidity
Absol.
R
0
0
99,9
2263 from
the
value
From
R
23
23
62
2264 value
of
the
room
humidity
Room
R
0
0
100
2265 calculated
value
of
the
room
absolute
humidity
Absol.
R
0
0
99,9
2266 from
the
value
From
R
23
23
62
2267 power
factor
of
dehumidification
function
Pf.Deh.
R
0
0
100
2268 power
factor
of
humidification
Pf.Hum.
R
0
0
100
2269 state
of
enthalpy
control
Enthalpy
R
0
0
1
User
User
User
Control
Control
Control
Control
Control
Unit
Control
Room
Supply
Room
Sp
Supply
Sp
Humidity
Cust.
Signal
Temperature
User
User
User
User
CLIMATIC
RT_UNITARY
‐
IOM
‐
1508
‐
E
.
83
.
Содержание CLIMATIC series
Страница 2: ......
Страница 60: ...58 CLIMATIC RT_UNITARY IOM 1508 E...