• 61 •
50
Analog
R
0.0
~
100.0
51
Analog
R
0.0
~
100.0
52
Analog
R
-99.9
~
99.9
53
Analog
R
-99.9
~
99.9
54
Analog
R
-99.9
~
99.9
55
Analog
R
-99.9
~
99.9
56
Analog
R
0.0
~
100.0
57
Analog
R
0.0
~
100.0
58
Analog
R
0.0
~
100.0
59
Analog
R
0.0
~
100.0
60
Integer
R
0
~
65536
61
Integer
R
0
~
65536
62
Integer
R
0
~
65536
63
Integer
R
0
~
65536
64
Integer
R
0
~
65536
65
Integer
R
0
~
65536
66
Integer
R
0
~
65536
67
Integer
R
0
~
65536
68
Integer
R
0
~
65536
69
Integer
R
0
~
65536
70
Integer
R
0
~
65536
71
Integer
R
0
~
65536
72
Integer
R
0
~
32767
73
-32768
~
32767
74
Integer
R
0
~
65536
CLIMATIC RT_UNITARY-IOM-1508-E
BMS
@Address
R/W
DESCRIPTION
MIN
Fact.
MAX
hot water coil, opening percentage calculated for the valve
humidi
fi
er, power percentage calculated for the proportional signal
remote control, value of the signal, be-1 b1, temperature
remote control, value of the signal, be-1 b2, temperature
remote control, value of the signal, be-1 b3, temperature
remote control, value of the signal, be-1 b4, temperature
remote control, value of the signal, be-1 b1, humidity
remote control, value of the signal, be-1 b2, humidity
remote control, value of the signal, be-1 b3, humidity
remote control, value of the signal, be-1 b4, humidity
unit, count value (weight low) of operating time
unit, count value (weight high) of operating time
blower, count value (weight low) of operating time
blower, count value (weight high) of operating time
circuit 1 compressor 1, count value (weight low) of operating time
circuit 1 compressor 1, count value (weight high) of operating time
circuit 1 compressor 2, count value (weight low) of operating time
circuit 1 compressor 2, count value (weight high) of operating time
circuit 2 compressor 1, count value (weight low) of operating time
circuit 2 compressor 1, count value (weight high) of operating time
circuit 2 compressor 2, count value (weight low) of operating time
circuit 2 compressor 2, count value (weight high) of operating time
blower, calculated value of air
fl
ow
not used
Alarm, 1
bit.0 = (70) Real Time Clock
bit.1 = (71) BE.1, Communication Bus
bit.2 = (72) BE.2, Communication Bus
bit.3 = (9) Unit power supply
bit.4 = (81) Room Temperature, Probe
bit.5 = (82) Room Humidity, Sensor
bit.6 = (83) Outside Temperature, Probe
bit.7 = (85) Supply Temperature, Probe
bit.8 = (88) Return Temperature, Probe
bit.9 = (22) Supply Temperature, Too Low
bit.10 = (80) Air Flow, Sensor
bit.11 = (73) Blower, Inverter, Communication Bus
bit.12 = (1) Blower, Flow Switch Cut Off
bit.13 = (91) Blower, Fan
bit.14 = (92) Blower, Inverter
bit.15 = (99) Fire / Smoke, Detected