INSTALLATION AND OPERATION 

MANUAL 

 

  
 
   
 
 

  
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                         
 

                               

    
    

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Freestanding Model  

T300P Series

 

RETAIN THESE 

INSTRUCTIONS 

FOR FUTURE 

REFERENCE 

FREESTANDING 

PELLET FIRED 

STOVES 

These appliances must be properly installed and operated in order to
prevent the possibility of a house fire. Please read this entire owner's
manual before installing and using your pellet stove. Failure to follow 
these instructions could result in property damage, bodily injury or even
death. Contact your local building or fire officials to obtain a permit and
information on any installation requirements and inspection require-
ments in your area. 

P/N 775025M, Rev. E, 1

2

/03 

Содержание Traditions T300P Series

Страница 1: ...rder to prevent the possibility of a house fire Please read this entire owner s manual before installing and using your pellet stove Failure to follow these instructions could result in property damage bodily injury or even death Contact your local building or fire officials to obtain a permit and information on any installation requirements and inspection require ments in your area P N 775025M Re...

Страница 2: ...asional running on the maximum setting during the coldest periods of the winter The blower speed control should be turned to high when operating the stove on the high heat setting 12 CAUTION NEVER PUT FINGERS NEAR AUGER Pellet fuel is fed to the UltraGrate by a screw au ger This auger is driven by a high torque motor The auger is capable of doing serious harm to fin gers Keep pellets in the hopper...

Страница 3: ...eeding the 35 to 1 by weight ratio are exempt from EPA regulations and are non affected facilities PRODUCT IS SUBJECT TO CHANGE WITHOUT NO TICE CONGRATULATIONS ON THE PURCHASE OF YOUR NEW PELLET STOVE MANUFACTURED BY LENNOX HEARTH PRODUCTS When you purchased your new pellet stove you joined the ranks of thousands of concerned indi viduals whose answer to their home heating needs reflects their con...

Страница 4: ...ir required 5 Rooms where the installation is not allowed INSTALLATION MAINTENANCE STANDARDS National Fire Protection Association The primary NFPA standard that refers to installation and mainte nance of pellet appliances and venting is NFPA 211 Chimneys Fireplaces Vents and Solid Fuel appli ances Jan 2000 SELECTING A LOCATION The design of your home and where you place your stove will determine i...

Страница 5: ...ector extends horizontally over the floor the protection must cover the floor under the connector and at least 2 to either side A noncombustible floor protector must fully cover the area beneath the appliance and extend 6 to the front 6 to the sides and up to 6 from the back as illustrated below Note When installed at clearances less than 6 floor protection is only required to extend to the wall T...

Страница 6: ... Flue Directly Through Wall Interior Vertical Flue Model T300P Series Clearance to Combustibles inch millimeter inch millimeter A Sidewall to unit 6 153 mm 6 153 mm B Backwall to unit 2 51 mm 9 229 mm C Sidewall to unit Corner 2 51 mm 2 51 mm D Max Depth of Alcove 18 458 mm 18 458 mm E Flue to Wall 3 77 mm 3 77 mm Measured to outside projection of cast stove top Minimum Alcove Measurements Height ...

Страница 7: ...s through A 1 2 rod could pass through but should not be able to touch the pipe when inserted through the opening a distance of 4 inches REMOVING APPLIANCE FROM PALLET 1 After removing the packaging from the stove lift the hopper lid and remove all pre packaged items that were shipped in the hopper Next open the stove door and remove all pre packaged items 2 Remove screws which secure legs to pall...

Страница 8: ...sh pan It is very important to preset your damper prior to burning your pellet stove The damper plate contains nine notches spaced in 1 4 increments that aid in positioning see Fig A For initial setup push the damper all the way in when facing the front of the stove in is to the left and out is to the right and slowly pull back three notches see Fig B This setting should provide an adequate air to...

Страница 9: ...on 3 Loosen the two terminal screws on the terminal block and remove the jumper 4 Connect the two wires from your thermostat to the terminals one per terminal Ensure that the purple wires from the harness remain connected to the ter minal block and tighten the terminal screws Make sure the wires are firmly connected to the thermo stat 5 Plug in the stove and you are ready to operate with your ther...

Страница 10: ... the stove Total Offsets in venting system should not exceed 270 total in direction change Horizontal Runs The maximum total horizontal run must not exceed 10 feet 3 1 meters Horizontal run of pipe requires 1 4 7 mm rise per foot Pipe Clearances Requirements See pipe manufac turers instructions for installation of venting components and clearances Follow pipe manufacturers installation precautions...

Страница 11: ...oes not expose people or shrubs to high heat from the exhaust gases The exhaust gases are not hot enough to ignite grass plants and shrubs located in the vicinity of the termination although they should be a minimum of 3 92M away The grade surface un der the termination must not be a lawn F Since sparks may escape from the exhaust pipe of any stove use caution when positioning the vent pipe Refer ...

Страница 12: ...Total Equivalent Feet 90 o Elbows x 5 Ft 1 5M 45 o Elbows x 3 Ft 1M Horizontal Pipe x 1 Ft 3M Vertical Pipe x 5 Ft 15M A 90 Degree Elbow E 8 Vertical Pipe B 1 Horizontal Pipe F 2 Horizontal Pipe C 45 Degree Elbow G 90 Degree Tee D Standoff Braces H Wall Thimble NOTE All equivalent pipe styles shown to the right are standard for all freestanding models SAMPLE INSTALLATION CHART Type of Pipe of El b...

Страница 13: ...r pushes into the bead of RTV sealer 3 Push the stove with pipe attached towards wall Pipe will go through the wall thimble Do not position the back of the stove closer than 1 25mm from the wall NOTE Greater back clearance will improve the ser viceability of the stove 4 Install listed type PL 45 degree elbow with rodent screen or cap optional on outside end of pipe The rodent screen should be no l...

Страница 14: ...ION CONFIGURATIONS Standard Horizontal Installations Note Horizontal run of pipe requires 1 4 7 mm rise per foot Page 14 If you vent to the fur thest wall the vent pipe must maintain a 3 clearance parallel to the other wall ...

Страница 15: ...g flue should be sealed with a steel plate Start a vertical run with a Tee at the back of the stove Other options are illustrated below Note See page 11 for Vent Termi nation Requirements Preferred Installation Vertical Vent Through the Roof This venting configuration allows for the best stove performance The vertical pipe promotes natural draft and with the chimney inside the dwelling the flue ga...

Страница 16: ...s is a safety precaution to protect against overheating Blower settings can be changed at any time but will only take affect after the start up cycle is complete Fault Mode The control system automatically moni tors the flame using a photoeye If the stove runs out of pellets the control board automatically goes into a fault status The control board will initiate the shut down cycle and safely shut...

Страница 17: ...he stove can be restarted at any time during the cool down mode by press ing the ON OFF button once Start up Sequence of Events 1 Fault time delay is initiated 14 minutes 15 seconds 2 Fuel feed rate of 100 for 1 minute 50 seconds when trim left at factory setting of 0 auger trim setting ranges from 1 26 to 2 14 depending on 4 to 4 respectively 3 Exhaust blower operation starts medium range volt ag...

Страница 18: ...n op erating without a thermostat The automatic mode is used when utilizing a wall thermostat When utilizing the thermostat capability the burn time can be extended dramatically depending on thermostat setting Note It is normal for some ash to build up on the inner glass sur face at the lower burn settings Initial Start Up Empty Hopper or Feed Tube During an initial start up or in the case where t...

Страница 19: ...f your stove All lights will re main on when the thermostat is open The heat and blower settings can be changed at any time but only take affect during the run mode When the temperature in the room drops to the level set at the thermostat the stove will again begin the start up cycle and resume automatic op eration in the demand mode NOTE If the stove on off switch is pressed while the thermostat ...

Страница 20: ...ot properly seated will starve the fire for air See Routine Maintenance pages 22 25 for information on cleaning the stove Excessive Combustion Air By closing the damper this will reduce combustion air delivery Symptoms of excessive air include fuel burns too quickly results in smoking or smoldering pellets white to yellow flame etc If the damper is open too much the burning pellets will lift off t...

Страница 21: ...owers motors and electronic controls and is not rec ommended Typical approved operation would include running at the low to mid range setting with occasional running on the maximum setting during the coldest peri ods of the winter The blower speed control should be turned to high when operating the stove on the high heat setting A lower heat setting is recommended for over night operation or when ...

Страница 22: ...UltraGrate as excessive amounts of ash will block combustion air from entering the grate causing pellets to pile up in the grate The ash build up under the grate is easily dumped into the ash pan by pulling out the ash slide weekly as shown below The grate cleaning procedure is the same for all models UltraGrate Recommended Frequency of 1 day 2 weeks ASH PAN The ash pan will have to be emptied per...

Страница 23: ...ass filter secured in place by a bracket and 2 nuts it is on the left when viewed while facing the front of the stove Using a 11 32 nut driver remove the 2 nuts and lift off the bracket Using your finger slide fil ter up and out 2 Wipe away any dust or debris from filter then rein stall filter filter bracket and cover plate with photo eye IMPORTANT When reinstalling photoeye and cover be careful n...

Страница 24: ...e opening of the firebox Continue pulling until the tube scraper reaches the top of the firebox It may be easier to clean the tubes by first removing the heat exchanger baffle Loosen the two screws holding the baffle in place do not fully remove The baffle con tains keyhole slots allowing the screws to remain in place while removing the baffle The scraper can now be pulled in a more horizontal man...

Страница 25: ...her side of the glass Window Wash Recommended Frequency of 1 year REAR STOVE COMPARTMENT The rear stove compartment should be cleaned periodi cally a minimum of once a year DISCONNECT ELEC TRICAL CORD PRIOR TO CLEANING STOVE Any household dust pet hair or sawdust should be vac uumed or wiped out of the rear compartment of the stove room air blower and Exhaust Blower paying special attention to vac...

Страница 26: ... 3AG Fuse Igniter 6 amp 125 volt Heat Input Max 13 000 32 000 BTU hr Overall Efficiency 85 Emissions 0 43 gram hr varies w size and type of fuel EPA exempt Ship Weight 363 lbs Room Air Blower 150 CFM 1 5 amps 2175 rpm Auger Motor 1 RPM 4 amps Exhaust Blower 95 CFM 1 0 amps 2880 rpm Note Dimensions shown are approximations only BACK VIEW SIDE VIEW Non combustible thermal rated floor protection must...

Страница 27: ...om Air Blower jacket and is designed to de tect an overfire condition Disc for Combustion Air Inlet This disc is lo cated on the combustion air inlet and is designed to detect reversed flow If negative pressure in the dwelling i e An extremely tight house which may not supply adequate combustion and ventilation air causes the exhaust to pull back from the combus tion air inlet the heat from the ex...

Страница 28: ...WIRING DIAGRAM Page 28 ...

Страница 29: ...the amount of fuel Refill hopper See Pellets will not feed 3 below Allow stove to cool for 1 hour and re light If the stove has been operating at a medium to high burn rate and the room air blower has been turned down low then the fan should be turned up higher If this problem persists particularly at lower burn rates then the high limit disc should be replaced by your authorized Lennox Hearth Pro...

Страница 30: ...ler RTV DO NOT use a standard household vacuum or shop vac as the filters will leak the fine particles of ash Clean the stove with an approved ash vacuum ONLY 6 Stove acts as if a fire is present when there is not a fire in the grate Excessive sun light may be shining directly into firebox from window Block excessive sunlight Call your authorized Lennox Hearth Products dealer if problem persists 7...

Страница 31: ...r a complete set of 4 levelers order 2 kits 4 20950100 Rear Panel Assembly 20953006 Trivet Black Electrical Parts Item Part Description 5 12046300 Auger Motor 6 16055150 Control Board 7 12050011 Exhaust Blower combustion fan 8 12146109 Room Air Blower includes gasket and 4 nuts 9 12147705 High Limit Disc 250 DG L250 30F 60T21 Set of three 10 12150213 Igniter Probe 380 W 3 3 A 11 14750404 Photoeye ...

Страница 32: ...te Gasket Auger 5pc 23 11756300 Shaft Auger Misc Parts Item Part Description 17150029 Damper Rod Assembly Kit 24 20950110 Gasket Quick Disconnect 25 20950014 Baffle Heat Exchange 27 12055500 Tool Grate Scraper 12121413 Knob Ash Pan 26022H Touch Up Paint Black for enamel 26021H Touch Up Paint Green for enamel 26023H Touch Up Paint Sand for enamel ...

Страница 33: ...REPLACEMENT PARTS DIAGRAMS Page 33 1 2 3 4 6 7 8 10 11 12 5 9 ...

Страница 34: ...REPLACEMENT PARTS DIAGRAMS Page 34 14 15 16 17 20 21 22 24 25 23 27 13 18 ...

Страница 35: ...Optional Accessories Item Catalog Model Description Notes 1 14M16 TT G Trivet Gold Plated Replaces Standard Cast Black Trivet 2 H0252 DLS T30 Log Set 2 Piece 3 14M81 QDPC 4 Quick Disconnect Pipe Connector 4 Required if 4 Pipe is used 70K99 TSPK B Touch up Spray Paint Kit Black Metallic Black 12oz Spray Can 1 2 3 ...

Страница 36: ...INSTALLATION TIPS Page 36 ...

Страница 37: ...SIMPLE OPERATING INSTRUCTIONS LABEL Page 37 ...

Страница 38: ...T300P PELLET STOVE SAFETY LABEL Page 38 Note that your serial number is printed on the safety label located on the back of the stove Your stove s serial number is preceded by a WH Example WH 0000000 ...

Страница 39: ...Page 39 Dealer s Name Dealer s Address City State Zip Code Serial Number Date of Purchase Date Installed Notes SERVICE AND MAINTENANCE LOG Service Service Service Date Technician Description ...

Страница 40: ...1110 West Taft Avenue Orange CA 92865 ...

Отзывы: