PLANNING YOUR INSTALLATION
Page 5
FLOOR PROTECTION
This appliance requires noncombustible floor protection. If the floor protection is to be stone, tile, brick, etc., it must be mor-
tared or grouted to form a continuous non-combustible surface. If a chimney connector extends horizontally over the floor,
the protection must cover the floor under the connector and at least 2" to either side.
A noncombustible floor protector must fully cover the area beneath the appliance and extend 6” to the front, 6” to the
sides, and up to 6" from the back as illustrated below.
*Note: When installed at clearances less than 6”, floor protection is only required to extend to the wall.
T300P SERIES
* Up to 6"/153mm
minimum
6"
(153mm}
6"
(153mm}
6"
(153mm}
Содержание Traditions T300P Series
Страница 28: ...WIRING DIAGRAM Page 28 ...
Страница 33: ...REPLACEMENT PARTS DIAGRAMS Page 33 1 2 3 4 6 7 8 10 11 12 5 9 ...
Страница 34: ...REPLACEMENT PARTS DIAGRAMS Page 34 14 15 16 17 20 21 22 24 25 23 27 13 18 ...
Страница 36: ...INSTALLATION TIPS Page 36 ...
Страница 37: ...SIMPLE OPERATING INSTRUCTIONS LABEL Page 37 ...
Страница 40: ...1110 West Taft Avenue Orange CA 92865 ...