Lennox Hearth Products LMDV-33 Series Скачать руководство пользователя страница 4

4

note: diaGraMs & iLLustrations are not to scaLe.

Figure 2

sit and Honeywell Millivolt Gas Valve 

showing piezo igniter Location (each unit is 

equipped with only one of these Gas Valves) 

 

Millivolt  appliances 

-    Appliances  with 

Millivolt systems will be fitted with the gas 

control valve shown in Figures 4 or 5. 

 

electronic  appliances

  -  Appliances  with 

electronic  systems  will  be  fitted  with  the 

electronic valve shown in Figure 3. 

Millivolt appliances - 

To light millivolt appli-

ances refer to the detailed lighting instructions 

found on Pages 18 & 19 

Millivolt appliance 

lighting instructions may also be found on the 

pull out lighting instruction labels attached to 

the gas control valve

.

Millivolt appliances are fitted with an OFF/ON 

Rocker  Switch  located  behind  the  control 

compartment  access  door,  below  the  appli-

ance front glass enclosure panel (see 

Figure 2 

for location).  Once the pilot is lit, the OFF/ON 

rocker switch will control the appliance OFF/ON 

burner operation.  To operate:  Toggle the switch 

between its ON and OFF positions.

If your millivolt appliance is equipped with an 

optional remote switch kit (wall switch, remote 

control or wall thermostat) and the pilot is lit, 

the appliance main burner may be turned on 

and off using the optional switch. When using 

an optional remote switch, turn off the standard 

OFF/ON switch.

Note: To prevent excessive resistance in burner 

circuit (which can cause burner operation prob-

lems), only one burner control switch should be 

wired to valve. Therefore, if an optional control 

switch is installed, the standard Off/On switch 

and wires should be removed.

sit Gas Valve

shown with control 

compartment door 

removed

piezo igniter

Honeywell

Gas Valve

 If your electronic appliance is equipped with an 

optional remote wall switch or remote control kit 

the appliance main burner may be turned on and 

off with the wall switch or remote control.

If  your  electronic  appliance  is  not  equipped 

with a wall switch or remote control, the main 

burner must be turned off and on with the gas 

control switch. Toggle the switch from ON to 

OFF to operate the main burner .

Variable Flame Height adjustment 

(Millivolt appliances only) 

1

. All Millivolt appliances are equipped with a 

variable gas control valve. Flame height for 

these  models  may  be  adjusted  through  a 

range between fixed low and high settings 

while the appliance is in operation. Adjust 

the flame height as desired after lighting the 

appliance by rotating the variable adjustment 

control knob (HI/LO) located on the front of 

the valve (refer to 

Figures 4 & 5 

)

2.

 During the first initial burns of these appli-

ances, there will be some odor emitted (see 

Burn-In Period

 on Page 3 

)

Honeywell Millivolt Gas Valve

Figure 5

ON

OFF

P

IL

OT

LO

HI

OF

F

ON

OF

F

ON

Figure 3

Optional Blower OFF/ON 

Rocker Switch

SIT Millivolt  Gas Valve

Gas

outlet

Gas

inlet

pilot adjustment 

screw

terminals

tptH,tp & tH

Figure 4

HI

L O W

HT

PT

HT

PT

PILO

T

PIL

OT

ON

ti

OFF

IN

OUT

O

FF

O

N

O

FF

O

N

Hi/Lo Variable 

Flame Height 

adjustment

Manifold pressure tap

inlet pressure tap

piezo igniter

Main Gas 

control Knob

oFF/piLot/on

piezo igniter

Optional Burner OFF/ON 

Rocker Switch

piezo igniter

Optional Blower OFF/ON 

Rocker Switch

Optional Burner OFF/ON 

Rocker Switch

Hi/Lo Variable 

Flame Height 

adjustment

Main Gas 

control Knob

oFF/piLot/on

Manifold pressure 

tap

piezo igniter

inlet pressure tap

Gas

outlet

Gas

inlet

Honeywell Electronic  Gas Valve

FF

O

NI

P

S

I

N

O

L

O

RT

N

O

C

GI

N

TIER

Manifold pressure 

port

on/oFF switch

inlet 

pressure

port

electronic Gas 

control Valve

electronic appliances -

To light electronic appliances refer to the detailed 

lighting instructions found on Pages 20 & 21 

of  these  instructions.    Electronic  appliance 

lighting instructions may also be found on the 

pull out lighting instruction labels attached to 

the gas control valve.

Содержание LMDV-33 Series

Страница 1: ...OWED EXACTLY A FIRE OR EXPLO SIONMAYRESULTCAUSINGPROPERTYDAMAGE PERSONAL INJURY OR LOSS OF LIFE WARNINGS Hot Do not touch The glass and surfaces of this appliance will be hot during operation and will...

Страница 2: ...LMDV 4035CNM LMDV 4035CPM 28 000 Table 3 TABLE OF CONTENTS Introduction Page 2 General Information Page 2 Gas Controls Access Page 3 Operation Care of Your Appliance Page 3 Variable Flame Adjustment...

Страница 3: ...latest edition Gas Pressure Tables 4 5 and 6 show the appliances gas pressure requirements Manifold Gas Supply Pressure millivolt models Fuel Low High Natural Gas Lo 2 2 WC 55 kPa Hi 3 5 WC 87 kPa Pr...

Страница 4: ...and off with the wall switch or remote control If your electronic appliance is not equipped with a wall switch or remote control the main burner must be turned off and on with the gas control switch T...

Страница 5: ...se improper and dangerous opera tion Verify proper operation after servicing Inspect and clean all wire connections Ensure that there is no melting or damage Inspection should include Terminals at the...

Страница 6: ...EXERCISE EXTREME CAUTION to prevent the occurrence of any burn injuries from the exposedflamesorhotsurfaces Alsonote that while the front glass enclosure panel or any of the panels is removed the fla...

Страница 7: ...8 Logs should be placed in the order shown and per the following instructions WARNING DONOTattempttoinstallthelogs until the appliance installation hasbeencompleted thegasline connected and tested fo...

Страница 8: ...log E fits over pin on log A A V Shapeareaoflog E should aligntosidesofburnerports Log C fitsinto indentinLog A A SlotonbottomofLog C fitsoverbracket SlotonbottomofLog D fitsoverbracket Log D fits in...

Страница 9: ...notches onlog bottom rest on locating brackets Notch on log bottom fits over bracket Notch on log bottom fits over bracket SlotonbottomofLog D fitsoverbracket LOG SET Catalog Number H3365 Item Descrip...

Страница 10: ...for a few more minutesto ensure that the flame normalizes and the flames do not appear sooty The following chart is provided to aid you in achieving the correct air shutter adjustment for your install...

Страница 11: ...ot generator thermopile and the top 1 8 minimum tip of the quick drop out thermocouple should be engulfed in the pilot flame The flame should project 1 25 mm beyond the hood at all three ports See Fig...

Страница 12: ...blower into J Box receptacle for FBK 100 or FBK 200 application See View A for J Box wiring Optional Blower OFF ON Switch Integral with Gas Valve Honeywell Electronic Gas Valve 120 VAC Primary Second...

Страница 13: ...can be installed directly in the gas valve mounting bracket millivolt gas valve equipped fireplaces to provide On Off operation in lieu of a wall switch Standard Remote Control System The Model RCL S...

Страница 14: ...0C 40 Sq Doors Charcoal LMDV 4035 H0951 SD40TI 40 Sq Doors Textured Iron H0952 SD40SP 40 Sq Doors Satin Pewter H0953 SD40AB 40 Sq Doors Antique Brass Style View Doors Square Pane Design Kits H0962 SPD...

Страница 15: ...speed 80L85 FBK 200 Blower Variable Speed w wall mounted switch 80L86 FBK 250 Blower Variable Speed w unit mounted switch 94L89 FBK 100 36 Blower Standard 36Pack 94L90 FBK 200 36 Blower Kit Variable...

Страница 16: ...e kits can be retrofitted to previously installed appliances ref Form 504 142M Eyebrow Hood Kits Polished Brass Brushed Stainless Models Where Used Cat Model Cat Model 98L10 EB33PB 98L11 EB33BS LMDVT...

Страница 17: ...Crescent Style lower grille shown ref Form 750 202M Note Door Trim Kits are for 1 side only If set is desired order 2 kits Decorative Grille Kits These decorative grilles are offered in two attractive...

Страница 18: ...echnician Force or attempted repair may result in a fire or an explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the app...

Страница 19: ...rique Ne vous servez d aucun t l phone dans votre difice Appelezimm diatementvotrecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter votre compagnie de gaz appelez le...

Страница 20: ...mediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Lighting Instructions Electronic 1 F...

Страница 21: ...ent pour faire inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteu...

Страница 22: ...or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform...

Страница 23: ...e switch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or rem...

Страница 24: ...24V common leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identifyproperlead thischeckmust be done with the valve control con nected and igniter powered NO Check...

Страница 25: ...25 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE NOTE THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 26: ...Logo 12L15 is sold separately Gas Controls SIT Millivolt Natural Gas Propane Gas Part No Qty Part No Qty 12 Gas Valve SIT H1657 1 88J53 1 13 Piezo Igniter 10K86 1 10K86 1 14 Pilot Assembly 69L17 1 69...

Страница 27: ...O SCALE NOTE THIS PAGE INTENTIONALLY LEFT BLANK NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts PA I N T 7 8 1 2 9 10 13 12 6 19 11 3 5 15 18 16 14 17 4 24 25 26 27 23 22 30 29 32 28 20...

Страница 28: ...875 028M REV E 02 2008 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products...

Отзывы: