note: diaGraMs & iLLustrations are not to scaLe.

WirinG diaGraMs

Wiring diagrams are provided here for refer-

ence purposes only.  This information is also 

provided on schematics attached directly to the 

appliance on a pullout panel located within the 

control compartment. 

TH

TP

TH

TP

 

 

 

 

thermopile

if any of the original wire as supplied must 

be replaced, it must be replaced with type 

aWM 105

o

 c - 18 gage wire.

* optional Kits installed - oFF/on wall switch, 

wall thermostat or remote control receiver. 

note:  turn  the  appliance-mounted  oFF/on 

burner control switch to the oFF position if 

any of these kits are installed. 

Millivolt Wiring diagram

schematic representation only

Field Wired

Factory 

Wired

*optional   switch

standard oFF/on switch

      caution  

Label all wires prior to discon-

nection  when  servicing  con-

trols.  Wiring errors can cause 

improper and dangerous appli-

ance operation.

Figure 16

Figure 17

electronic Wiring diagram (Honeywell) showing Blower Wiring for optional FBK-100, FBK-200 & FBK-250 Kits

schematic representation only

Relay Module C/W FBK-250 only. Plug blower 

into J-Box receptacle for FBK-100 or FBK-200 

application. See View A for J-Box wiring.

Optional Blower

*OFF/ON Switch 

(Integral with 

Gas Valve)

Honeywell

Electronic

Gas

Valve

120 VAC

Primary

Secondary

Optional Control Switch

Junction Box

Pilot Burner

Assembly

BL

BL

Field Wired
Factory 

Wired

BK = BLACK   BL = BLUE

R = RED         W = WHITE

G = GREEN

BK

W

BK

BK

BL

R

GROUND

24 V

Transformer

       View A 

J-Box Wiring when 

using unit mounted 

relay module.

BK

W

G

CA

02

1

Igniter

Connector

*  Leave the OFF/ON switch, which is 

integral with the gas valve, in the ON 

position.

**

Optional Control Switches

: Wall 

Switch, Wall Thermostat or Remote 

Control Receiver.

Notes:

1. If any of the original wire as supplied 

must be replaced, use Type AWM 105°C 

- 18 gage wire ONLY.

2. 120 VAC, 60 Hz - Less than 3 Amps.

Caution: label all wires prior to 

disconnection when servicing controls. 

Wiring errors can cause improper and 

dangerous operation.

Junction Box 

Tab Intact

Tab 

Broken

Plug blower

into this 

receptacle

n

e

e

r

G

 -

 

d

n

u

o

r

G

* Wall-mounted

ON/ OFF Blower 

Switch or Variable 

Speed Control Switch. 

Blower

Ground

e

ti

h

W

 -

 l

a

rt

u

e

N

120 VAC - Black

Green

Ground

Screw

White

Green

Neutral 

Side of

Receptacle

Hot

Side of

Receptacle

Red

Black

J-BOX WIRING FOR 

WALL SWITCH 

BLOWER CONTROL

Содержание LMDV-33 Series

Страница 1: ...OWED EXACTLY A FIRE OR EXPLO SIONMAYRESULTCAUSINGPROPERTYDAMAGE PERSONAL INJURY OR LOSS OF LIFE WARNINGS Hot Do not touch The glass and surfaces of this appliance will be hot during operation and will...

Страница 2: ...LMDV 4035CNM LMDV 4035CPM 28 000 Table 3 TABLE OF CONTENTS Introduction Page 2 General Information Page 2 Gas Controls Access Page 3 Operation Care of Your Appliance Page 3 Variable Flame Adjustment...

Страница 3: ...latest edition Gas Pressure Tables 4 5 and 6 show the appliances gas pressure requirements Manifold Gas Supply Pressure millivolt models Fuel Low High Natural Gas Lo 2 2 WC 55 kPa Hi 3 5 WC 87 kPa Pr...

Страница 4: ...and off with the wall switch or remote control If your electronic appliance is not equipped with a wall switch or remote control the main burner must be turned off and on with the gas control switch T...

Страница 5: ...se improper and dangerous opera tion Verify proper operation after servicing Inspect and clean all wire connections Ensure that there is no melting or damage Inspection should include Terminals at the...

Страница 6: ...EXERCISE EXTREME CAUTION to prevent the occurrence of any burn injuries from the exposedflamesorhotsurfaces Alsonote that while the front glass enclosure panel or any of the panels is removed the fla...

Страница 7: ...8 Logs should be placed in the order shown and per the following instructions WARNING DONOTattempttoinstallthelogs until the appliance installation hasbeencompleted thegasline connected and tested fo...

Страница 8: ...log E fits over pin on log A A V Shapeareaoflog E should aligntosidesofburnerports Log C fitsinto indentinLog A A SlotonbottomofLog C fitsoverbracket SlotonbottomofLog D fitsoverbracket Log D fits in...

Страница 9: ...notches onlog bottom rest on locating brackets Notch on log bottom fits over bracket Notch on log bottom fits over bracket SlotonbottomofLog D fitsoverbracket LOG SET Catalog Number H3365 Item Descrip...

Страница 10: ...for a few more minutesto ensure that the flame normalizes and the flames do not appear sooty The following chart is provided to aid you in achieving the correct air shutter adjustment for your install...

Страница 11: ...ot generator thermopile and the top 1 8 minimum tip of the quick drop out thermocouple should be engulfed in the pilot flame The flame should project 1 25 mm beyond the hood at all three ports See Fig...

Страница 12: ...blower into J Box receptacle for FBK 100 or FBK 200 application See View A for J Box wiring Optional Blower OFF ON Switch Integral with Gas Valve Honeywell Electronic Gas Valve 120 VAC Primary Second...

Страница 13: ...can be installed directly in the gas valve mounting bracket millivolt gas valve equipped fireplaces to provide On Off operation in lieu of a wall switch Standard Remote Control System The Model RCL S...

Страница 14: ...0C 40 Sq Doors Charcoal LMDV 4035 H0951 SD40TI 40 Sq Doors Textured Iron H0952 SD40SP 40 Sq Doors Satin Pewter H0953 SD40AB 40 Sq Doors Antique Brass Style View Doors Square Pane Design Kits H0962 SPD...

Страница 15: ...speed 80L85 FBK 200 Blower Variable Speed w wall mounted switch 80L86 FBK 250 Blower Variable Speed w unit mounted switch 94L89 FBK 100 36 Blower Standard 36Pack 94L90 FBK 200 36 Blower Kit Variable...

Страница 16: ...e kits can be retrofitted to previously installed appliances ref Form 504 142M Eyebrow Hood Kits Polished Brass Brushed Stainless Models Where Used Cat Model Cat Model 98L10 EB33PB 98L11 EB33BS LMDVT...

Страница 17: ...Crescent Style lower grille shown ref Form 750 202M Note Door Trim Kits are for 1 side only If set is desired order 2 kits Decorative Grille Kits These decorative grilles are offered in two attractive...

Страница 18: ...echnician Force or attempted repair may result in a fire or an explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the app...

Страница 19: ...rique Ne vous servez d aucun t l phone dans votre difice Appelezimm diatementvotrecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter votre compagnie de gaz appelez le...

Страница 20: ...mediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Lighting Instructions Electronic 1 F...

Страница 21: ...ent pour faire inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteu...

Страница 22: ...or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform...

Страница 23: ...e switch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or rem...

Страница 24: ...24V common leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identifyproperlead thischeckmust be done with the valve control con nected and igniter powered NO Check...

Страница 25: ...25 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE NOTE THIS PAGE INTENTIONALLY LEFT BLANK...