accessorY coMponents

* assembled 8-piece Louver Kits

polished Brass

Brushed stainless

Models 

Where used

cat. #

Model

cat. #

Model

H1522 LK-400B

H1523

LK-400Bs

LMdVt-3328

LMdVr-3328

H1524 LK-500B

H1525

LK-500Bs

LMdV-3530

H1526 LK-600B

H1527

LK-600Bs

LMdV-4035

polished Brass & Brushed stainless 2-piece door Frame Kits

These kits are designed  to attach directly to the front face of the appliance at the glass enclosure panel's top 

and bottom edges.

(ref. Form # 750,098M)

2- piece door Frame Kits

polished Brass

Brushed stainless

Models 

Where used

cat. #

Model

cat. #

Model

98L18

2dFK33pB

98L19

2dFK33Bs

LMdVt-3328

LMdVr-3328

26M88

2dFK35pB

26M91

2dFK35Bs

LMdV-4035

26M89

2dFK40pB

26M92

2dFK40Bs LMdV-4035

polished Brass & Brushed stainless Louvers Kits

These kits include a top 4-louver assembly and a bottom 4-louver assembly.  They provide a touch of elegance.  

These kits can be retrofitted to previously installed appliances.

(ref. Form # 750,166M)

polished Brass & Brushed stainless Hood Kits

Attractive hoods are available in two styles. These hoods are designed to be fitted to the glass viewing sides 

of the appliance. In addition to providing an aesthetically pleasing appearance to your appliance installation, 

the hood reduces heat effects to decorative mantles and finish materials located above the fireplace opening. 

The hood kit replaces the standard hood that comes with these appliances and snaps into place.  These kits 

can be retrofitted to previously installed appliances.

(ref. Form #504,142M)

eyebrow Hood Kits

polished Brass

Brushed stainless

Models 

Where used

cat. #

Model

cat. #

Model

98L10

eB33pB

98L11

eB33Bs

LMdVt-3328

LMdVr-3328

96K67

eB35pB

88L49

eB35Bs

LMdV-4035

96K68

eB40pB

88L50

eB40Bs

LMdV-4035

* these hood kits replace the standard hood that comes with 

these fireplaces.

door Frame Kits

A decorative door frame kit is available for use with these appliances. It is designed to attach directly to the front face 

of the appliance at the four edges of the glass enclosure panel resulting in the appearance of a picture frame. 

(ref. Form # 750,098M)

4 piece door trim Kits

polished Brass

Brushed stainless

Models 

Where used

cat. #

Model

cat. #

Model

98L22

4dFK33pB

98L23

4dFK33Bs

LMdVt-3328

LMdVr-3328

26M82

4dFK35pB

26M85

4dFK35Bs LMdV-3530

26M83

4dFK40pB

26M86

4dFK40Bs LMdV-4035

* Lennox Nameplate Logo, 12L15, is sold separately.

touch-up paint Kit

Repair of minor scratches and discoloration of the 

appliance charcoal painted surfaces may be accom-

plished with the touch-up paint kit.

touch-up paint Kits

(all models)

cat. no.

Model no.

description

90L74

tpK-c

touch-up paint (charcoal)

(TPK-C ref. Form # 504,216M)

PA I N T

Ref. 750,109M

Ref. 750,055M

termination Guard Kits

(all models)

cat. no.

Model no.

description

H5820

4.5HtsK

termination shroud

87L02

sV4.5HGs

termination Guard, 

deluxe

17M52

sV4.5HGs-1

termination Guard, 

square

Square Termination 

Guard

Deluxe Termination 

Guard

termination Guard Kits

The vent termination guards may be used to cover 

the  vent  termination  on  the  exterior  of  the  home 

to  minimize  exposure  to  the  hot  surface  of  the 

termination. 

Termination Shroud

Содержание LMDV-33 Series

Страница 1: ...OWED EXACTLY A FIRE OR EXPLO SIONMAYRESULTCAUSINGPROPERTYDAMAGE PERSONAL INJURY OR LOSS OF LIFE WARNINGS Hot Do not touch The glass and surfaces of this appliance will be hot during operation and will...

Страница 2: ...LMDV 4035CNM LMDV 4035CPM 28 000 Table 3 TABLE OF CONTENTS Introduction Page 2 General Information Page 2 Gas Controls Access Page 3 Operation Care of Your Appliance Page 3 Variable Flame Adjustment...

Страница 3: ...latest edition Gas Pressure Tables 4 5 and 6 show the appliances gas pressure requirements Manifold Gas Supply Pressure millivolt models Fuel Low High Natural Gas Lo 2 2 WC 55 kPa Hi 3 5 WC 87 kPa Pr...

Страница 4: ...and off with the wall switch or remote control If your electronic appliance is not equipped with a wall switch or remote control the main burner must be turned off and on with the gas control switch T...

Страница 5: ...se improper and dangerous opera tion Verify proper operation after servicing Inspect and clean all wire connections Ensure that there is no melting or damage Inspection should include Terminals at the...

Страница 6: ...EXERCISE EXTREME CAUTION to prevent the occurrence of any burn injuries from the exposedflamesorhotsurfaces Alsonote that while the front glass enclosure panel or any of the panels is removed the fla...

Страница 7: ...8 Logs should be placed in the order shown and per the following instructions WARNING DONOTattempttoinstallthelogs until the appliance installation hasbeencompleted thegasline connected and tested fo...

Страница 8: ...log E fits over pin on log A A V Shapeareaoflog E should aligntosidesofburnerports Log C fitsinto indentinLog A A SlotonbottomofLog C fitsoverbracket SlotonbottomofLog D fitsoverbracket Log D fits in...

Страница 9: ...notches onlog bottom rest on locating brackets Notch on log bottom fits over bracket Notch on log bottom fits over bracket SlotonbottomofLog D fitsoverbracket LOG SET Catalog Number H3365 Item Descrip...

Страница 10: ...for a few more minutesto ensure that the flame normalizes and the flames do not appear sooty The following chart is provided to aid you in achieving the correct air shutter adjustment for your install...

Страница 11: ...ot generator thermopile and the top 1 8 minimum tip of the quick drop out thermocouple should be engulfed in the pilot flame The flame should project 1 25 mm beyond the hood at all three ports See Fig...

Страница 12: ...blower into J Box receptacle for FBK 100 or FBK 200 application See View A for J Box wiring Optional Blower OFF ON Switch Integral with Gas Valve Honeywell Electronic Gas Valve 120 VAC Primary Second...

Страница 13: ...can be installed directly in the gas valve mounting bracket millivolt gas valve equipped fireplaces to provide On Off operation in lieu of a wall switch Standard Remote Control System The Model RCL S...

Страница 14: ...0C 40 Sq Doors Charcoal LMDV 4035 H0951 SD40TI 40 Sq Doors Textured Iron H0952 SD40SP 40 Sq Doors Satin Pewter H0953 SD40AB 40 Sq Doors Antique Brass Style View Doors Square Pane Design Kits H0962 SPD...

Страница 15: ...speed 80L85 FBK 200 Blower Variable Speed w wall mounted switch 80L86 FBK 250 Blower Variable Speed w unit mounted switch 94L89 FBK 100 36 Blower Standard 36Pack 94L90 FBK 200 36 Blower Kit Variable...

Страница 16: ...e kits can be retrofitted to previously installed appliances ref Form 504 142M Eyebrow Hood Kits Polished Brass Brushed Stainless Models Where Used Cat Model Cat Model 98L10 EB33PB 98L11 EB33BS LMDVT...

Страница 17: ...Crescent Style lower grille shown ref Form 750 202M Note Door Trim Kits are for 1 side only If set is desired order 2 kits Decorative Grille Kits These decorative grilles are offered in two attractive...

Страница 18: ...echnician Force or attempted repair may result in a fire or an explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the app...

Страница 19: ...rique Ne vous servez d aucun t l phone dans votre difice Appelezimm diatementvotrecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter votre compagnie de gaz appelez le...

Страница 20: ...mediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Lighting Instructions Electronic 1 F...

Страница 21: ...ent pour faire inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteu...

Страница 22: ...or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform...

Страница 23: ...e switch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or rem...

Страница 24: ...24V common leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identifyproperlead thischeckmust be done with the valve control con nected and igniter powered NO Check...

Страница 25: ...25 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE NOTE THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 26: ...Logo 12L15 is sold separately Gas Controls SIT Millivolt Natural Gas Propane Gas Part No Qty Part No Qty 12 Gas Valve SIT H1657 1 88J53 1 13 Piezo Igniter 10K86 1 10K86 1 14 Pilot Assembly 69L17 1 69...

Страница 27: ...O SCALE NOTE THIS PAGE INTENTIONALLY LEFT BLANK NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts PA I N T 7 8 1 2 9 10 13 12 6 19 11 3 5 15 18 16 14 17 4 24 25 26 27 23 22 30 29 32 28 20...

Страница 28: ...875 028M REV E 02 2008 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products...