Lennox Hearth Products LMDV-33 Series Скачать руководство пользователя страница 21

21

note: diaGraMs & iLLustrations are not to scaLe.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

INSTRUCTIONS D’ALLUMAGE — ELECTRONIC

INSTRUCTIONS D’ALLUMAGE

POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE

A.

Lorsque vous allumez l’appareil, suivez exactement ces instruc-

tions.

B. AVANT L’ALLUMAGE:

Assurez-vous que   vous ne détectez

aucune odeur de gaz autour de l’apareil ainsi que près du sol;

certains gaz, étant plus lourds que l’air, descendent au niveau du

sol.

VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS DÉCELEZ UNE

ODEUR DE GAZ

Éteignez toute flamme visible.

Ouvrez les fenêtres.

N’allumez aucun appareil.

Ne touchez à aucun commutateur électrique.

Ne vous servez d’aucun téléphone dans votre édifice.

AVERTISSEMENT: SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU

UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE.

Appelez immédiatement votre compagnie de gaz en utilisant

le téléphone du voisin.

S’il vous est impossible de contacter votre compagnie de

gaz, appelez le service des incendies.

C.

N’utilisez que votre main pour manipuler linterrupteur “ON/

OFF” de la valve à gaz.  N’utilisez jamais d’outils.  Si

l’interrupteur ne bouge pas manuellement, n’essayez pas de le

réparer.  Communiquez immèdiatement avec un technicien de

service qualifié.  Toute tentative pour forcer l’interrupteur ou le

réparer, risquerait de provoquer un incendie ou une explosion.

D.

Ne vous servez pas de cet appareil si l’un de ses éléments a été

immergé  dans  l’eau.  Appelez  immédiatement  un  technicien

compétent pour faire inspecter l’appareil et remplacer toute

pièce du système de réglage ou commande du gaz qui a été sous

l’eau.

1. ARRÊTEZ !

 Lisez les consignes de sécurité au verso de cette

plaque.

2.

Tournez l’interrupteur mural à la position d’arrêt “OFF”.

3.

Ouvrez la porte du compartiment de contrôle du bas.

4.

Assurez-vous que la soupape d’arrêt de la canalisation principale

est ouverte.

5.

Tournez la manette de réglage du gaz à la position d’arrêt “OFF”.

6.

Attendez  cinq  (5)  minutes  pour    l’evacuation  du  gaz.  Si  vous

décelez une odeur de gaz  ARRÊTEZ !  Retournez au point “B” des

consignes  de  sécurité  au  verso  de  cette  plaque.  Si  vous  ne

remarquez aucune odeur de gaz, passez à l’étape suivante.

7.

Tournez la manette de réglage du gaz jusqu’à la position de marche

“ON”. Ne la forcez pas.

8.

Ouvrez  le  courant  électrique  (“ON”)  qui  alimente  l’appareil

(interrupteur mural).

9.

  Fermez la porte du compartiment de contrôle du bas.

10.

  Au besoin, rebrancher l’apareil au courant électrique et

remettre l’interrupteur principal du brûleur à la position “ON”

ou régler le thermostat à la température désirée.

11.

  Si l’appareil ne se met pas en marche, suivre les instructions

intitulées “Pour fermer le gaz qui alimente l’appareil” et appeler

un technicien ou le fournisseur de gaz.

POUR ÉTEINDRE L’APPAREIL

1.  

 Coupez tout le courant électrique qui alimente l’appareil (interrupteur

mural).

POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL

3.

Tournez la manette de réglage du gaz à la position d’arrêt “OFF”.

Ne la forcez pas.

4.

Fermez la soupape d’arrêt de la canalisation principale.

5.

Fermez la porte du compartiment de contrôle du bas.

1.

Pour une fermeture complète, tournez l’interrupteur mural à la

position d’arrêt “OFF”.

2.

Ouvrez la porte du compartiment de contrôle du bas.

Interrupteur

ON/OFF

FF

O

NI

I

S

P

N

O

L

O

RT

N

O

C

RE

TI

N

GI

Vue de face

Содержание LMDV-33 Series

Страница 1: ...OWED EXACTLY A FIRE OR EXPLO SIONMAYRESULTCAUSINGPROPERTYDAMAGE PERSONAL INJURY OR LOSS OF LIFE WARNINGS Hot Do not touch The glass and surfaces of this appliance will be hot during operation and will...

Страница 2: ...LMDV 4035CNM LMDV 4035CPM 28 000 Table 3 TABLE OF CONTENTS Introduction Page 2 General Information Page 2 Gas Controls Access Page 3 Operation Care of Your Appliance Page 3 Variable Flame Adjustment...

Страница 3: ...latest edition Gas Pressure Tables 4 5 and 6 show the appliances gas pressure requirements Manifold Gas Supply Pressure millivolt models Fuel Low High Natural Gas Lo 2 2 WC 55 kPa Hi 3 5 WC 87 kPa Pr...

Страница 4: ...and off with the wall switch or remote control If your electronic appliance is not equipped with a wall switch or remote control the main burner must be turned off and on with the gas control switch T...

Страница 5: ...se improper and dangerous opera tion Verify proper operation after servicing Inspect and clean all wire connections Ensure that there is no melting or damage Inspection should include Terminals at the...

Страница 6: ...EXERCISE EXTREME CAUTION to prevent the occurrence of any burn injuries from the exposedflamesorhotsurfaces Alsonote that while the front glass enclosure panel or any of the panels is removed the fla...

Страница 7: ...8 Logs should be placed in the order shown and per the following instructions WARNING DONOTattempttoinstallthelogs until the appliance installation hasbeencompleted thegasline connected and tested fo...

Страница 8: ...log E fits over pin on log A A V Shapeareaoflog E should aligntosidesofburnerports Log C fitsinto indentinLog A A SlotonbottomofLog C fitsoverbracket SlotonbottomofLog D fitsoverbracket Log D fits in...

Страница 9: ...notches onlog bottom rest on locating brackets Notch on log bottom fits over bracket Notch on log bottom fits over bracket SlotonbottomofLog D fitsoverbracket LOG SET Catalog Number H3365 Item Descrip...

Страница 10: ...for a few more minutesto ensure that the flame normalizes and the flames do not appear sooty The following chart is provided to aid you in achieving the correct air shutter adjustment for your install...

Страница 11: ...ot generator thermopile and the top 1 8 minimum tip of the quick drop out thermocouple should be engulfed in the pilot flame The flame should project 1 25 mm beyond the hood at all three ports See Fig...

Страница 12: ...blower into J Box receptacle for FBK 100 or FBK 200 application See View A for J Box wiring Optional Blower OFF ON Switch Integral with Gas Valve Honeywell Electronic Gas Valve 120 VAC Primary Second...

Страница 13: ...can be installed directly in the gas valve mounting bracket millivolt gas valve equipped fireplaces to provide On Off operation in lieu of a wall switch Standard Remote Control System The Model RCL S...

Страница 14: ...0C 40 Sq Doors Charcoal LMDV 4035 H0951 SD40TI 40 Sq Doors Textured Iron H0952 SD40SP 40 Sq Doors Satin Pewter H0953 SD40AB 40 Sq Doors Antique Brass Style View Doors Square Pane Design Kits H0962 SPD...

Страница 15: ...speed 80L85 FBK 200 Blower Variable Speed w wall mounted switch 80L86 FBK 250 Blower Variable Speed w unit mounted switch 94L89 FBK 100 36 Blower Standard 36Pack 94L90 FBK 200 36 Blower Kit Variable...

Страница 16: ...e kits can be retrofitted to previously installed appliances ref Form 504 142M Eyebrow Hood Kits Polished Brass Brushed Stainless Models Where Used Cat Model Cat Model 98L10 EB33PB 98L11 EB33BS LMDVT...

Страница 17: ...Crescent Style lower grille shown ref Form 750 202M Note Door Trim Kits are for 1 side only If set is desired order 2 kits Decorative Grille Kits These decorative grilles are offered in two attractive...

Страница 18: ...echnician Force or attempted repair may result in a fire or an explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the app...

Страница 19: ...rique Ne vous servez d aucun t l phone dans votre difice Appelezimm diatementvotrecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter votre compagnie de gaz appelez le...

Страница 20: ...mediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Lighting Instructions Electronic 1 F...

Страница 21: ...ent pour faire inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteu...

Страница 22: ...or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform...

Страница 23: ...e switch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or rem...

Страница 24: ...24V common leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identifyproperlead thischeckmust be done with the valve control con nected and igniter powered NO Check...

Страница 25: ...25 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE NOTE THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 26: ...Logo 12L15 is sold separately Gas Controls SIT Millivolt Natural Gas Propane Gas Part No Qty Part No Qty 12 Gas Valve SIT H1657 1 88J53 1 13 Piezo Igniter 10K86 1 10K86 1 14 Pilot Assembly 69L17 1 69...

Страница 27: ...O SCALE NOTE THIS PAGE INTENTIONALLY LEFT BLANK NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts PA I N T 7 8 1 2 9 10 13 12 6 19 11 3 5 15 18 16 14 17 4 24 25 26 27 23 22 30 29 32 28 20...

Страница 28: ...875 028M REV E 02 2008 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products...